Guardian Manual 001-5006-000 Rev 0
31 |
P a g e
Table 5-1 – Communications Modes
Mode
Description
Sync/ESC with No HS
Sends data using Sync/byte-stuffing protocol without handshaking.
Buffered with No HS
Sends buffered data without handshaking (this mode required for DOX
operation.)
This is the Default.
Sync/Esc with RTS/CTS HS
Sends data using the Sync/Esc byte-stuffing protocol with RTS/CTS hardware
handshaking.
Buffered with RTS/CTS HS
Sends buffered data with RTS/CTS hardware handshaking.
Sync/Esc with Flow Control HS
Sends data using the Sync/Esc byte-stuffing protocol with flow control
handshaking.
Buffered with Flow Control HS
Sends buffered data with flow control hardware handshaking.
5.1.3
PORT STATISTICS
The
Port Statistics
screen is accessed via the
Utilities
pull-down menu. Port Statistics show current parameters of
the PC’s Primary and Secondary COM Ports.
Figure 5-4 – Port Statistics Screen
Baud Rate
Baud Rate shows the current baud rate setting for the Primary and Secondary COM ports.
RTS
RTS shows the current state of the RTS (request to send) line. RTS is an output from the PC.
DTR
DTR shows the current state of the DTR (data terminal ready) line. DTR is an output from the PC.