FRP 4000 Fireplace Owner’s Manual
Page
LTR20081045, Rev. A
Installation and Assembly
Installation must conform with local building and/or fire
codes, or in the absence of local codes:
National Fuel Gas Code ANSI Z223.1 / INFPA 54
(for installation in the United States)
CSA B149.1 Natural Gas and CAN/CGA-BIL/9-
2, Propane Installation code (for installation in
Canada).
Location
Place your fireplace on a flat and stable surface in an
outdoor location such as a patio deck. Do not locate the
appliance where it can get excessively wet or submerged
in water.
When determining a suitable location, take into account
concerns such as exposure to wind, proximity to traffic
paths, and windows that open into the home.
Locate your fireplace adjacent to the gas supply line
(LP or NG), preferably with the shortest gas line run
possible.
Maintain the following clearances to combustible
materials. Measure from the outside of the unit.
Bottom
0 inches
Sides (all around) 48 inches (1.2 m)
Top
72 inches (1.8 m)
•
•
Installation
Installation and service must be performed by a
qualified installer, service agency or your natural
gas or liquid propane (LP) gas provider .
Leak Testing Procedure
Perform a leak test at least once a year whether the
gas supply cylinder has been disconnected or not. In
addition, whenever the gas cylinder is connected to
the regulator or whenever any part of the gas system
is disconnected or replaced, perform a leak test.
As a safety precaution, remember to always leak
test your fireplace outdoors in a well-ventilated area.
Never smoke or permit sources of ignition in the area
while doing a leak test. Do not use a flame, such as
a lighted match to test for leaks. Use a solution of
soapy water.
Prepare a leak testing solution of soapy water by
mixing in a spray bottle one part liquid soap to
one part water.
Make sure all the control knobs are in the OFF
position.
Turn on the gas.
On
natural gas systems
, turn the main feed
valve to the grill.
On
LP systems
, turn the cylinder valve knob
counter clockwise one turn to open.
Apply the leak-testing solution by spraying it
on joints of the gas delivery system. Blowing
bubbles in the soap solution indicates that a leak
is present.
Stop a leak by tightening the loose joint or by
replacing the faulty part with a replacement
part recommended by the manufacturer. Do not
attempt to repair the cylinder valve if it is damaged.
The cylinder must be replaced.
Turn all control knobs back to the full OFF
position.
If you are unable to stop a leak:
Turn all control knobs back to the full OFF
position.
Shut off the gas supply to the fireplace and release
pressure in the hose and manifold by pushing in
and turning any of the control valves one quarter
turn counter-clockwise.
On LP systems, remove the cylinder from the
fireplace.
Call a qualifiedgas appliance service technician.
Do not use the appliance until the leak is corrected.
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
Your Cal Flame fireplace is designed and intended for
OUTDOOR USE ONLY in a well ventilated space and
must not be used inside a building, garage, or any
other enclosed area.