Appendix

See  your  local  code  compliance  office  for  a  copy  of 

the applicable warranty, details and any questions you 

may  have  regarding  the  warranty  coverage  on  your 

fireplace.
L.M.S.  warrants  the  fireplace  from  defects  in  material 

and  workmanship  for  a  period  of  one  year  from  the 

original date of purchase.
All  stainless  steel  components  are  warranted  against 

defects for two years from date of purchase. All other 

parts (such as igniter, hose assembly, etc.) are covered 

and  Cal-Flame  will  provide  replacement  parts  free  of 

charge during the first year of the limited warranty. To 

obtain replacement warranty parts, call your Cal Flame 

customer  service  and  be  prepared  to  provide  proof  of 

purchase  via  fax  or  mail.  Parts  will  be  shipped  at  no 

charge. Labor related to warranty repair is not covered. 

Any  repair  work  must  be  done  by  a  qualified  gas 

appliance technician.

In the first year only, this warranty extends to the repair 

or replacement of warranted parts which are defective 

in  material  or  workmanship  provided  that  the  product 

has  been  operated  in  accordance  with  the  operation 

instructions and under normal conditions.

Warranty Conditions and Limitations

The Limited Warranty is void if the fireplace has been 

subject to negligence, alteration, misuse, abuse, repairs 

by  non-L.M.S.  authorized  representatives,  incorrect 

electrical installation, acts of God and any other cases 

beyond the control of L.M.S. Examples of common acts 

invalidating this warranty include but are not limited to:

Scratches caused by normal use.

Damage  caused  by  extreme  weather  conditions 

(heat, cold, etc.).

Damage  caused  by  dirt,  sand,  and/or  water 

damage.

Damage  caused  by  continued  operation  of  the 

fireplace with either known or unknown problems.

Damage caused by direct sunlight.

Damage caused as a result of failure to follow the 

operating  instructions  as  defined  in  this  owner’s 

manual.

Misuse

Lack of maintenance

Accident

Alterations

Abuse

Neglect

The  use  of  components  not  supplied  with  the 

appliance

The use of fuel other than those specified

Weather, including freezing damage, long periods of 

dampness, or condensation

Damaging chemical or cleaners

Parts installed from other manufacturers

This Limited Warranty applies only to fireplaces normally 

used  for  personal,  family,  or  household  purposes  and 

specifically excludes commercial fireplaces.
Cal-Flame warrants its products against manufacturing 

defects of the original purchaser only, (i.e., the individual, 

legal entity or registered customer whose name appears 

on  the  original  receipt  or  warranty  card  filed  with  Cal-

Flame) – provided that the purchase was made through 

an authorized Cal Flame reseller and is subject to the 

following condition and limitations:

This  limited  warranty  applies  only  while  the  unit 

remains at the site on original installation and only if 

the unit is installed in Canada or the United States.
This  factory  warranty  is  nontransferable  and 

may  not  be  extended  whatsoever  by  any  of  our 

representatives.

Installation  must  be  done  in  accordance  with  the 

installation instruction included with the product and 

all local and national building and fire codes. Natural 

gas  units  must  be  installed  by  an  authorized  gas 

appliance technician.

The original bill of sale will be required together with 

a model number when making any warranty claims 

from  Cal  Flame  customer  service.  The  warranty 

registration  card  (if  included  with  kit)  must  be 

returned within 0 days of purchase to register the 

warranty.

Fire logs carry no warranty.

Disclaimer

Natural  stone:  Rock,  travertine,  marble,  etc.  may  be 

characterized  by  dry  seams,  pits,  chips,  cracks,  and 

fossils that are often filled with grout during installation. 

These are normal imperfections and are not considered 

defects.

Fireplace Warranty

Содержание FPR 4000

Страница 1: ...LTR20081045 Rev A 3 1 08...

Страница 2: ...use Lloyds Material Supply L M S will not be held responsible for an improperly installed gas line Copyright 2008 Lloyds Material Supply Inc All rights reserved Duplication without written consent is...

Страница 3: ...s well as solvents cleaning fluids and gasoline Do not block the vents located near the base of your fireplace as gas may build up in case of leak and cause serious damage Do not install or operate yo...

Страница 4: ...ve the control compartment burner and circulation air passageways of the appliance be kept clean and free Any guard or other protective device removed for servicing the appliance must be replaced prio...

Страница 5: ...precaution remember to always leak test your fireplace outdoors in a well ventilated area Never smoke or permit sources of ignition in the area while doing a leak test Do not use a flame such as a lig...

Страница 6: ...Enclosures Ensure cylinder valves are always readily accessible A door on the enclosure to gain access to the cylinder valve is acceptable provided it is non locking and can be opened without the use...

Страница 7: ...and restrain it to prevent it from tipping Connection Inspect the hose shipped with the unit for damage Never attempt to use damaged or plugged equipment See your local LP gas technician for repairs A...

Страница 8: ...ned shut off valve with easy access Your Cal Flame fireplace for use with natural gas comes equipped with its own regulator which MUST NOT be removed If this regulator needs to be replaced use only th...

Страница 9: ...nce Once the fireplace is in position level and safely hooked up to the proper fuel supply install the log grate over the plate burner Place the lava rock around the flat burner plate DO NOT place the...

Страница 10: ...he burner FIRST You must have clear and easy access to the ON OFF valve AFTER the appliance is installed and connected to the gas supply in order to safely turn of the burner Make sure the burner is i...

Страница 11: ...or gas suppliler Pushinthegascontrolknobandturncounterclockwise to the ON position 1 2 3 4 5 6 7 8 To light the burners turn the gas control that regulates gas flow to the burners Turn it from LOW to...

Страница 12: ...ve buildup To clean the logs be sure the fire is out the gas supply is turned off and the logs are cool to the touch The soot can then be brushed of with a dry bristle brush or cloth Take care while c...

Страница 13: ...y direct sunlight Damage caused as a result of failure to follow the operating instructions as defined in this owner s manual Misuse Lack of maintenance Accident Alterations Abuse Neglect The use of c...

Страница 14: ...d below Fireplace model _______________________________________________________________________ Fireplace serial number _________________________________________________________________ Type of fuel c...