FRP 4000 Fireplace Owner’s Manual
Page 9
LTR20081045, Rev. A
Operation
This appliance has a pilot which must be manually lit.
When lighting the pilot, follow these instructions exactly.
Open the fireplace screens.
Push in the gas control knob slightly and turn it
clockwise to the OFF position.
Note: The knob cannot be turned unless pushed in
slightly. Do not force the knob to turn.If you do not smell
gas, proceed to the next step.
Locate the pilot burner on the right hand side
between the base logs.
Push the knob IN slightly and turn it counterclockwise
to the PILOT position.
Push the control knob all the way in and hold it in.
Immediately press the ignitor (piezo) button to light
the pilot.
Continue to hold the control knob in for about one
minute after the pilot is lit.
After one minute, release the knob. It will pop back
out and the pilot should remain lit. If the pilot goes
out, repeat steps 2 through .
If the knob does not pop out when released, stop and
immediately call your service technical or gas supplier.
If the pilot will not stay lit after several tries, turn the
gas control to the OFF position and call your service
technician or gas suppliler.
Push in the gas control knob and turn counterclockwise
to the ON position.
1.
2.
3.
4.
5.
6.
7.
8.
To light the burners, turn the gas control that
regulates gas flow to the burners. Turn it from LOW
to HIGH to increase the gas flow.
Close the fireplace screens.
When the appliance is being operated for the first time,
allow for a supervised burn of 0 minutes. Then shut the
appliance off and let it cool completely before relighting.
This allows proper curing time for the logs. (After several
hours of operation the logs will discolor slightly. This is
normal.)
Manual Thermostat
Operation of the thermostat is based on the position of the
control lever. While turning the lever to the ON position,
note the position the main burner ignites. Leaving the
lever at this position would cause the burner to operate
until the room temperature warms up slightly, then start a
gradual flame reduction until the temperature stabilizes.
Millivolt Control
The millivolt control lever allows for flame height and
heat output adjustment. Turn the lever counter-clockwise
from the LOW position to increase flame to the HIGH
position and clockwise to decrease flame.
Turning Off the Gas for Your Gas Fireplace
Open the fireplace screens.
Push in the gas control knob slightly and turn it
clockwise to the OFF position.
9.
10.
1.
2.
Fireplace Lighting Instructions
Содержание FPR 4000