Top Gun Barbecue Grill
LTR50001121, Rev. A
Appendix
www.calflamebbq.com
31
All Cal Flame grills are manufactured as standard
liquid propane (LP) grills and can be converted to
burn natural gas (NG). There are two steps required
to convert a grill from LP to NG.
You must perform both steps.
Step 1: Switching the regulator behind the
grill
Step 2: Changing the burner orifices
The conversion kit provided with your grill may
include
some or all
of the parts shown at right,
depending on the size and model of your grill.
The kit contains orifices to convert main burners,
rear infrared burners, and the large infrared burner.
Your kit will have only the parts you need to convert
your grill.
Before you begin, make certain the LP gas source
has been disconnected from the grill.
To gain access to the NG regulator, tilt the grill
forward.
Step 1: Switching the regulator
behind the grill
The manifold in the image below has been removed from a grill to illustrate
this procedure.
Remove the LP gas line.
1.
Remove the cap fitting from the end of the NG gas regulator.
2.
Place the cap fitting over the LP gas inlet.
3.
Insert a male flared fitting (
4.
not provided
) in the NG gas regulator.
Converting from LP to NG
WARNING! You must have an authorized service technician perform this
procedure. If these instructions are not followed exactly, a fire or explosion may
result causing property damage, personal injury or loss of life . Lloyd’s Material Supply
(LMS) will not be held responsible for an improperly converted gas grill .
You will need:
13mm open end wrench
•
Male flared fitting
•
(not provided)
Pipe compound suitable
•
for natural gas
NOTE: A flared fitting is NOT included
with your grill .
If you are attaching a flex hose to the regulator,
you will need a fitting. The fitting requires a male
flare on the input end with a 1/2” MPT on the
output end. The flared male input end needs to be
the size of your flex tubing. You can also connect
the regulator directly to your NG gas service, which
will not require a flared fitting.