2009 Barbecue Grills and Carts
LTR20091038, Rev. E
Installation /
Assemb
ly
www.calspas.com
5
Gas Requirements and Connection
Gas Requirements and Connection
IMPORTANT: The Cal Flame grill is manufactured to operate on liquid propane (LP). However, it can be
converted to operate on natural gas (NG) by an authorized service technician. Consult your Cal Flame dealer
for information on converting your gas grill.
Owners must not convert their grills themselves . Attempting to convert the grill from LP to NG
may result in serious injury and will void the warranty coverage .
If you do not have an updated filler valve on your existing propane tank, you will need to purchase one at
your local hardware store. Without it you will not be able to attach your tank to your Cal Flame™ grill or
refill the tank at your local propane refill station.
Leak Testing Procedure
Perform a leak test at least once a year whether the
gas supply cylinder has been disconnected or not.
In addition, whenever the gas cylinder is connected
to the regulator or whenever any part of the gas
system is disconnected or replaced, perform a leak
test.
As a safety precaution, remember to always leak test
your grill outdoors in a well-ventilated area. Never
smoke or permit sources of ignition in the area while
doing a leak test. Do not use a flame, such as a
lighted match to test for leaks. Use a solution of
soapy water.
Prepare a leak testing solution of soapy water by
1.
mixing in a spray bottle one part liquid soap to
one part water.
Make sure all the control knobs are in the OFF
2.
position.
Turn on the gas.
3.
On
a.
natural gas systems
, turn the main feed
valve to the grill.
On
b.
LP systems
, turn the cylinder valve knob
counter clockwise one turn to open.
Apply the leak-testing solution by spraying it
4.
on joints of the gas delivery system. Blowing
bubbles in the soap solution indicates that a leak
is present.
Stop a leak by tightening the loose joint or by
5.
replacing the faulty part with a replacement
part recommended by the manufacturer. Do
not attempt to repair the cylinder valve if it is
damaged. The cylinder must be replaced.
Turn all control knobs back to the full OFF
6.
position.
If you are unable to stop a leak:
Turn all control knobs back to the full OFF
1.
position.
Shut off the gas supply to the grill and release
2.
pressure in the hose and manifold by pushing
in and turning any of the control valves one
quarter turn counter-clockwise.
On LP systems, remove the cylinder from the
3.
grill.
Call an authorized gas appliance service
4.
technician or an LP gas dealer.
Do not use the appliance until the leak is corrected.