7/52 User Instructions
CAIROX
15/12/2021
4
TECHNICAL DATA SOLANO EASY PRO W
EASY PRO W-100
EASY PRO W-150
EASY PRO W-200
STEP
III
II
I
III
II
I
III
II
I
Power supply [V/Hz]
1N
230/50
Power consumption [W]
115
90
75
165
110
90
230
150
115
Current consumption [A]
0,5
0,4
0,3
0,7
0,5
0,4
1,0
0,6
0,5
Air volume [m
3
/h]*
1100
900
750
1950
1450
1200
2850
1800
1400
Air volume with filter (Coarse
30%) [m
3
/h]*
750
650
600
1300
1100
1000
1900
1600
1350
Range [m]*
3,2
2,8
2,1
3,2
2,8
2,1
3,2
2,8
2,1
Acoustic
pressure
level
[dB(A)]** - 3 m
55,5
50,5
46
57
48,5
45
59
46
38
Acoustic
pressure
level
[dB(A)]** - 5 m
54,5
49,5
45
56
47,5
44
58
45
37
Acoustic
power
level
[dB(A)]***
70,5
65,5
61
72
63,5
59
74
61
53
Weight [kg]
16,2
21,5
26,9
Weight of unit filled with
water [kg]
16,8
22,4
28,1
IP
20
Max. operating temperature
[°C]
30
Connection stub [‘’]
½ internal thread connection
Max. Water pressure [MPa]
1,6
Max. Water
temperature [°C]
110
Heating power [kW]****
1,2
–
12,1
2,6
–
21,0
3,7
–
29,3
Temperature
increase
(ΔT)[°C]****
3,0
–
32,5
4,0
–
32,0
4,0
–
30,5
* according to ISO 27327-1;
** Acoustic pressure level has been measured in a 1500m
3
space with a medium sound absorption coefficient, directional
factor: Q=2;
*** Acoustic power level according to ISO 27327-2;
**** Range of heating powers and temperatures specified for the parameters: III fan speed, heating medium temperature
40/30 ° C inlet temperature 20 ° C
-
III fan speed, heating medium temperature 110/90 ° C at the device inlet 0 ° C.