6. DOOR CONTACT INSTALLATION
7. GUIDELINES FOR CONNECTION WITH POWER SUPPLY
8. GUIDELINES FOR CONNECTION WITH PIPELINE
• Before connecting the power supply check the correctness of controllers connection. These connections
should be executed in accordance with their technical documentation.
• Before connecting the power supply check whether the mains voltage is in accordance with the voltage on
the device data shield.
• Starting the device without connecting the ground conductor is forbidden.
• The connection should be executed in a way which does not induce stresses. It is recommended to use
flexible pipes to deliver heating agent to the exchanger.
• It is recommended to install vent valves at the highest point of the system.
• The system should be executed so that, in the case of a failure, it is possible to disassemble the device. For
this purpose it is best to use shut-off valves just by the device.
• The system with the heating medium must be protected against an increase of the heating medium pressure
above the permissible value (1.6 MPa).
• While screwing exchanger to pipeline - connecting stubs has to be hold by wrench.
Sample of door contact installation.
S-DS-MEC
In case of installation in way
which is show on drawing below, connec-
tors 21 and 22 need to be used.
Hinged doors
S-DS-MAG
In the case of sliding doors (with a parallel
installation of the sensor and magnet ) is required distance
9-12 mm between the sensor housing and the magnet.
For Hinged door max 8 mm between housing and
magnet.
Содержание SOLANO CEILING-E-100
Страница 1: ...AIR CURTAIN TECHNICAL DOCUMENTATION...
Страница 8: ...8 4 INSTALLATION 7 9 11 13 8 10 12 14...
Страница 10: ...10 5 2 CONNECTING GUIDE 1 3 5 7 2 4 6 8 CEILING B W N CEILING B E...
Страница 21: ...21...
Страница 22: ...22...
Страница 23: ...23...
Страница 24: ...Made in Poland Made in EU Manufacturer OUEST ISOL VENTIL Z I de la Rangle 27460 ALIZAY...