6. DOOR CONTACT INSTALLATION

7. GUIDELINES FOR CONNECTION WITH POWER SUPPLY

8. GUIDELINES FOR CONNECTION WITH PIPELINE

•  Before connecting the power supply check the correctness of controllers  connection. These connections 

should be executed in accordance with their technical documentation. 

•  Before connecting the power supply check whether the mains voltage is in accordance with the voltage on 

the device data shield.

•  Starting the device without connecting the ground conductor is forbidden.

•  The connection should be executed in a way which does not induce stresses. It is recommended to use 

flexible pipes to deliver heating agent to the exchanger.

•  It is recommended to install vent valves at the highest point of the system.
•  The system should be executed so that, in the case of a failure, it is possible to disassemble the device. For 

this purpose it is best to use shut-off valves just by the device.

•  The system with the heating medium must be protected against an increase of the heating medium pressure 

above the permissible value (1.6 MPa).

•  While screwing exchanger to pipeline - connecting stubs has to be hold by wrench.

Sample of door contact installation.

S-DS-MEC 

In case of installation in way 

which is show on drawing below, connec-
tors 21 and 22 need to be used.
Hinged doors 

S-DS-MAG 

In the case of sliding doors (with a parallel 

installation of the sensor and magnet ) is required distance 
9-12 mm between the sensor housing and the magnet. 
For Hinged door max 8 mm between housing and 
magnet.

Содержание SOLANO CEILING-E-100

Страница 1: ...AIR CURTAIN TECHNICAL DOCUMENTATION...

Страница 2: ...installation electrical connection connection to the heating medium start up repairs and maintenance of air curtains observe the commonly recognized safety standards and regulations 1 TECHNICAL DATA...

Страница 3: ...hanger max range 5 m CEILING E 200 curtain with electrical heat exchanger max range 5 m CEILING W temperature increase at inlet air 10o C and heating agent temperature 90 70o C CEILING E temperature i...

Страница 4: ...N E 150 1546 mm 600 mm 561 mm 1207 mm 297 mm 84 mm CEILING W N E 200 2034 mm 600 mm 561 mm 1621 mm 297 mm 157 mm step W 100 E 100 N 100 W 150 E 150 N 150 W 200 E 200 N 200 3 2600 m3 h 3500 m3 h 4000...

Страница 5: ...7 1 7 2 290 310 316 0 6 0 6 0 7 19 0 18 5 18 0 2 5 2 5 2 6 72 74 75 0 1 0 1 0 1 13 5 13 0 12 5 15 5 7 6 1 6 2 248 266 271 0 5 0 5 0 6 22 5 22 0 21 5 2 1 2 2 2 2 62 63 64 0 1 0 1 0 1 18 0 17 5 17 5 20...

Страница 6: ...24 5 PT Qw pw Tp2 PT Qw pw Tp2 Tp1 V kW I h kPa C kW I h kPa C C m3 h Tw1 Tw2 90 70o C Tw1 Tw2 80 60o C 0 4000 4300 5200 27 6 28 7 31 8 1217 1266 1402 11 4 12 2 14 7 20 5 19 5 18 0 23 6 24 6 27 7 1038...

Страница 7: ...1 3 5 2 4 6 B A CEILING 100 572 mm 1024 mm CEILING 150 572 mm 1510 mm CEILING 200 572 mm 2000 mm C D E F CEILING 100 133 770 mm 121 mm 561 mm CEILING 150 182 1207 mm 122 mm 561 mm CEILING 200 256 1621...

Страница 8: ...8 4 INSTALLATION 7 9 11 13 8 10 12 14...

Страница 9: ...nnectors 1xNC i 1xNO Max current resistive 10A inductive 3A Max Power load 300Vac or 250Vdc S V 2 1 2 two way 1 2 valve with actuator IP Insulation class IP20 Power supply 200 240V 50 60Hz Max water t...

Страница 10: ...10 5 2 CONNECTING GUIDE 1 3 5 7 2 4 6 8 CEILING B W N CEILING B E...

Страница 11: ...umber of set fan speed T signalize of valve set DC signalize of door contact set OPEN CLOSE signalize valve actuator WORK signalize of software working SW3 operating mode switch default settings K1 pr...

Страница 12: ...MY 3x1mm2 Air curtain step switch with thermostat S C OMY 5x0 5mm2 Heat heating mode Fan room thermostat deactivated Cool cooling mode Door contact S DS MEC S DS MAG door closed contacts opened door o...

Страница 13: ...vercurrent B25 Air curtain step switch with thermostat S C OMY 5x0 5mm2 HEAT heating mode FAN room thermostat deactivated COOL cooling mode Door contact S DS MAG S DS MEC door closed contacts opened d...

Страница 14: ...raided wire pair max 50 m Door contact S DS MAG S DS MEC door closed contacts opened door opened contacts closed Valve with actuator S V 3 OMY 3x0 5mm2 or S V 2 OMY 3x0 5mm2 A Exchanger water supply A...

Страница 15: ...SOLANO CEILING E 200 min 5x6 mm2 Overcurrent B25 S touch LIYCY 4x0 5mm2 A and B braided wire pair max 50 m Door contact S DS MAG S DS MEC door closed contacts opened door opened contacts closed ATTENT...

Страница 16: ...directly Switch 2 on SW3 set In position For MASTER curtain For SLAVE curtain In case to connect several devices to one S TOUCH and independent local work of curtains with door switches use DRV IN DRV...

Страница 17: ...17 5 3 7 CONTROL SYSTEM APPLIANCES CHAINING NOTE In last appliance in line dipswitch SW2 has to be switched to the right T120 The maximum length of the connecting cable 50 m LIYCY 3x 0 5 mm2...

Страница 18: ...an 0 FAN_SPEED0 Fan is off 1 FAN_SPEED1 1st step of fan is on 2 FAN_SPEED2 2nd step of fan is on 3 FAN_SPEED3 3rd step of fan is on 2 0x06 CurtainHeatRef 0 1 Set value for thermostat 0 HEAT_OFF Curtai...

Страница 19: ...It is recommended to install vent valves at the highest point of the system The system should be executed so that in the case of a failure it is possible to disassemble the device For this purpose it...

Страница 20: ...me of performing inspection or cleaning the device the electrical power supply should be discon nected In case water is drained from the device for a longer period of time the exchanger tubes should b...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...Made in Poland Made in EU Manufacturer OUEST ISOL VENTIL Z I de la Rangle 27460 ALIZAY...

Отзывы: