background image

4

Rev022520

Installation

Clearance opening measured 

from inside edge of baseplate 

to baseplate

CONCRETE FLOOR ANCHOR INFO:

MIN. 3000 PSI CONCRETE

4" MIN. CONCRETE THICKNESS

3" MIN. EDGE DISTANCE (ALL SIDES)

Step 1

Illustration

VI.  Smart Gate Installation

NOTICE

 

Refer to parts list on Page 3 for part item numbers and descriptions.

NOTICE

 

Base plates are slotted to allow adjustment for alignment.

STEP 1. 

Mark holes for the Gate Post and anchor with concrete floor anchors. Measure and mark the center of the 

wall opening, using the Gate Size Reference Table to assist in centering the gate on the wall opening. (Gate 

Size Reference Drawing on Page 15).

Door Opening 

this side of 

Gate Post

SG SIZE REFERENCE TABLE

CLEAR OPENING WIDTHS

CLEARANCE HEIGHT

SG-60-PCY*

48”, 54” 60”, 66”, 72”, OR 78”

94 

1

/

4

” - 124

 

1

/

4

Red 

Decal

1

9.5

*SG-60-PCY:

a. Adjustable from a minimum of 48” to a maximum 78” clear opening.

b. Gate will fit 48”, 54”, 60”, 66”, 72” and 78” doors.

IMPORTANT! 

Follow Anchor Manufacturer's technical data manual/installation instructions for installation   

 

requirements and proper installation procedures. 

 

Field concrete foundation design and complete consolidation of concrete surrounding embedded  

 

item(s) anchorage points 

NOT

 by PS Safety Access

.

© CAI Safety Systems | (951) 465-7386 | https://caisafety.com | [email protected]

Содержание SG-60-PCY

Страница 1: ...ect to change without notice PS Safety Access reserves the right to make changes without notice in the specifications and materials contained herein and shall not be responsible for any damages includ...

Страница 2: ...ions in this manual II Operation Guidelines A The Smart Gate is designed to meet OSHA Railing Standard 1910 29 b B Operation in a manner other than intended could result in damage or less than accepta...

Страница 3: ...part list below Smart Gate Part List As shipped ITEM DESCRIPTION QTY 1 LDSG GATE POST 1 2 LDSG GATE CATCH 1 3 LDSG ADJ CLEVIS PCY 1 4 LDSG 2 LIFT ARM 5FT 2 5 LDSG 1 75 LIFT ARM 5FT 2 6 LDSG GATE END 1...

Страница 4: ...able to assist in centering the gate on the wall opening Gate Size Reference Drawing on Page 15 Door Opening this side of Gate Post SG SIZE REFERENCE TABLE CLEAR OPENING WIDTHS CLEARANCE HEIGHT SG 60...

Страница 5: ...lock nut Step 3 Illustration A Step 3 Illustration B STEP 2 Attach Adjustable Clevis red decal with 2 3 8 x 4 hex bolts 2 3 8 nylock nuts and 4 3 8 flat washers a Tighten bolts bracket height will be...

Страница 6: ...at finish do not slide beyond desired length STEP 4 Slide 1 3 4 Lower Lift Arm green decal into 2 Lift Arm red decal to the desired gate width a Insert 3 8 x 2 1 4 hex bolts aligning with pre drilled...

Страница 7: ...Adjustable Clevis red decal on Gate Post b Insert 3 8 x 3 hex bolt and tighten 3 8 nylock nut 4 9 1 9 11 9 3 Red Decal Red Decals STEP 7 Slide 1 3 4 Upper Lift Arm blue decal into 2 Lift Arm red deca...

Страница 8: ...nment STEP 9 Mark out holes for the Gate Catch and anchor with concrete floor anchors STEP 8 Use rubber mallet to gently hammer flange bearings into both sides of 1 3 4 Upper Lift Arm a Slide the Gate...

Страница 9: ...3 4 Lift Arm a Insert 3 8 x 2 1 4 hex bolt and tighten 3 8 nylock nut Step 11 Illustration B STEP 10 Add bumpers to Lower Lift Arms at both locations and snug with 1 4 bolts and 1 4 nylock capped nuts...

Страница 10: ...rom concrete floor anchors to free up the assembly and lay on the ground in the extended position for improved access during dampener installation NOTICE To protect the Powder Coat finish lay on cardb...

Страница 11: ...upward anchor Gate Post back onto the floor surface and tip gate down into Gate Catch As the gate approaches fully closed you should hear a loud noise of the dampener self setting STEP 15 Visually ve...

Страница 12: ...TION STEPS 13 15 TO INSTALL NEW DAMPENER AS SHOWN IN THIS OPERATIONS AND MAINTENANCE MANUAL STEP 2 Rotate gate to the open position gate arms vertical before proceeding with Step 3 CAUTION CAUTION Hig...

Страница 13: ...der an Edge SafeTM Lockout Kit part 514582 Gate lifts vertically a full 90 without Pinch Points Uniquely placed Dampener is mounted high up to prevent potential Pallet and Forklift damage Counter bala...

Страница 14: ...Yellow For EdgeSafeTM Lockout Kit order part 514582 Kit includes 1 Storage Bracket 1 Lock Pin 2 Bolts 2 Nylock Nuts and Installation Instructions TO ORDER PARTS CONTACT PS SAFETY ACCESS AT 877 446 151...

Страница 15: ...ce Height CLEAR OPENING 8 8 8 8 X SG Size Reference Drawing SG Size Reference Table CLEAR OPENING WIDTHS CLEARANCE HEIGHT SG 60 PCY 48 54 60 66 72 OR 78 94 1 4 124 1 4 CAI Safety Systems 951 465 7386...

Страница 16: ...eners at four corners of the gate can be tightened to reduce closing speed 4 If gate closes too slowly fasteners at four corners of the gate can be loosened to increase closing speed C Finishes 1 Insp...

Страница 17: ...spect at minimum annually Date Installed Product Model Number Serial Number Opening Identifier Number Location DATE INSPECTED INSPECTED BY Print Sign INSPECTION ITEMS NOTED CORRECTIVE ACTION CORRECTED...