2 WebControl
TM
I/O
The current hardware version of WebControl
TM
is equipped with a number of inputs
and outputs; these are shown in below in figure 1.0.
Figure 1.0 WebControl
TM
PCB inputs and outputs diagram
2.1 Power Supply Inputs
The DC power supply input is the electrical supply to the board. The recommended
input voltage is 9V DC. Any voltage greater than 12V applied to this input may
require adding heatsink to regulator, otherwise it may overheat.
2.2 TTL Output Port
The TTL logic level output port has 8 TTL outputs that can each be set or cleared
using web GUI command codes, or by setting up a PLC using the available inputs,
variables, and timers, so that the particular output is set when a particular condition is
met. The maximum current that can be sourced or sinked by one of these outputs at
a time is 20mA or 100mA for the whole board. TTL 0 level defined as 0-2V and TTL
1 level is define 3-5V with TTL 0 almost 0V and TTL 1 almost 5V depending on the