SERVICE & INSTALLATION MANUAL for Cafection's Encore Venti
8.3
Outlet Valves
Inspection: quarterly
Preventive maintenance: every 10,000 cycles
To avoid any issue related to mineral deposits, Cafection recommends rebuilding all outlet valves at
the same time using the valve repair kits (PETAN45, one kit needed for each valve).
Valve Leakage
Identify the leaking valve, change it or rebuild it.
If the leak originates from under the body of the valve or from the tank exit, try changing the conical
mounting seal in the first instance.
If the coffee valve is not watertight, water will accumulate in the brew chamber.
If it drips all night, the first coffee of the morning will be lukewarm.
The leakage may also cause the brew chamber to flood.
WARNING! Water is VERY HOT!
Removing and Installing the Valves
1. Turn off the machine and remove the back panel.
2. Unplug the tank lid’s connectors (fig. 1.1) and the valves
(fig. 1.2).
3. Completely drain water from the tank (see section 9.1).
4. Remove the tubes.
5. Unscrew the guard to be able to remove the tank.
6. Tilt the tank forward to have access to the valves.
7. Remove the valves. Replace or rebuild them.
8. Reinstall by repeating the steps in reverse order.
If a water filtration system is installed on the brewer, it is recommended to inspect it
on a monthly basis.
Fig. 1.1
Tank lid
Connectors
Double valve
Fig. 1.2
Valves
Triple valve
Tank guard
Valves
Conical
mounting seals