5.1 WALL-MOUNT INSTALLATION 

10

D

 

ue to the many different materials used on different walls,  it is highly recommended that you consult your  

local builder before you install this appliance on the wall. 

5 1.1

 

WALL-MOUNT INSTALLATION METHOD FOR CHFPV-20 AND SCW SERIES

 

.

SIDE

 

VIEW

18-1/2 (472mm)

"

6-3/4 (171mm)

"

Power Line

A

Have two people hold the appliance against the wall to determine the final

 

   

location

B.

 

Mark out location then mount the bracket onto the wall using the five supplied    

      screws

.

This bracket MUST have the hooks

 and be leveled.

C.

 

With the wall mounting bracket installed, have two people lift the appliance

 

   

up and insert the two hooks on the bracket into the two slots on the back of the  

      appliance.

 

D.

 

Check the appliance for stability, ensuring that the bracket will not break   

      free

 

from the wall

.

.

 

.

,

 

 

 

 

 

 

 

 

 

 

 facing upward

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 CHFPV-20, SCW-001, SCW-002, and SCW-003. 

Below is the illustration of SCW-001, for the wall mount bracket and the quantity of wall 

anchors that be used for other models, please see page3.

 Wall-mount installation method for

NOTE:

screwed into the wall studs where possible. If the wall studs cannot 

be used, ensure that the supplied plastic anchors are used to affix 

the bracket to the wall and the bracket is adequately secured.

 It is strongly recommended that the mounting bracket be 

Wall anchor×5

Wall Mount Bracket

Hooks

REAR

 

VIEW

4 (102mm)

"

Содержание CHFP-002

Страница 1: ...20 CHFP 50B the similar size as CHFP 30B CHFP 40B CHFP 60B CHFP 74B CHFP 74BS and CHFP 102B SCI 002 the similar size as SCI 001 and SCI 003 HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED N...

Страница 2: ...OTING 11 0 WARRANTY WELCOME CONGRATULATIONS MAINTENANCE 3 0 INTRODUCTION 5 1 1 WALL MOUNT INSTALLATION METHOD FOR CHFPV 20 AND SCW SERIES 5 1 2 WALL MOUNT INSTALLATION METHOD FOR CHFP B AND CHFP 74BS...

Страница 3: ...0B CHFP 74B CHFP 74BS CHFP 102B SCW 001 SCW 002 SCW 003 1 pc 13 sets 12 sets 18 sets CHFPV 20 CHFP 30B CHFP 40B CHFP 50B SCW 001 CHFP 60B CHFPN 60 CHFP 74B CHFPN 74 CHFP 74BS SCI 001 SCW 002 SCW 003 C...

Страница 4: ...sed or qualifed service person Do not strike or slam shut the appliance glass door Keep the packaging material out of reach of children and dispose of the material in a safe manner As with all plastic...

Страница 5: ...during installation please contact your local dealer Model Number CHFP 50B Description Wall mount recessed or free standing Appliance Voltage 120V AC Watts Max 1500W Amps 13 AMP Appliance Width 50 127...

Страница 6: ...8 861 219mm 56 1 2 20 1 2 5 1 8 1436 521 130mm 70 1 2 20 1 2 5 1 8 1792 521 130mm 98 1 2 20 1 2 5 1 8 2500 522 130mm 26 11 660 280mm 13 1 2 23 1 4 345 592mm 36 14 1 8 915 360mm 46 14 1 8 1168 360mm 60...

Страница 7: ...ppliance does not emit heat consult the operation section of this manual for further information D Use with a ETL or UL certified surge protector WARNING READ THESE INSTRUCTIONS COMPLETELY BEFORE BEGI...

Страница 8: ...nect appliance turn controls to off then remove plug from outlet Carefully remove the appliance from the box Prior to installing the appliance test to make sure the appliance operates properly by plug...

Страница 9: ...INSULATION AGAINST THE APPLIANCE THIS ELECTRIC APPLIANCE IS TESTED AND LISTED FOR USE ONLY WITH THE APPROVED OPTIONAL ACCESSORIES USE OF OPTIONAL ACCESSORIES NOT SPECIFICALLY TESTED FOR THIS ELECTRIC...

Страница 10: ...have two people lift the appliance up and insert the two hooks on the bracket into the two slots on the back of the appliance D Check the appliance for stability ensuring that the bracket will not br...

Страница 11: ...racket will not break free from the wall for screws NOTE CHFP 30B CHFP 40B CHFP 50B CHFP 60B CHFP 74B CHFP 74BS and CHFP 102B Below is the illustration of CHFP 50B for the wall mount bracket and the q...

Страница 12: ...P 50B for the quantity of wall anchors that be used for other models please see page3 Installation method for 5 2 2 INSTALLATION METHOD FOR CHFP B AND CHFP 74BS 5 2 1 INSTALLATION METHOD FOR SCW SERIE...

Страница 13: ...on the both sides of glass door into the holes in the box Then push down the glass door to its place FRONT VIEW 50 1270mm Screw 8 Stand 2 25 1 4 641mm A 5 3 FREE STANDING INSTALLATION NOTE nly for CH...

Страница 14: ...AND SCW SERIES Data Line Power Line A B To disconnect the data line and power line press the plastic connector then pull them out Plastic Connector Plastic Connector C Remove the glass door from appli...

Страница 15: ...m tray on the front of the appliance as illustrated Apply an even layer from side to side 15 6 2 1 6 INTERCHANGEABLE MEDIA BED KITS INCLUDED Morocco Dream Winter Flakes Tahiti Getaway Falling Stars Gl...

Страница 16: ...holes 6 3 GLASS DOOR INSTALLATION 6 3 1 GLASS DOOR INSTALLATION METHOD FOR CHFPV 20 AND SCW SERIES A To connect power line align the plastic connector and red dot then connect data line B Two people...

Страница 17: ...the right of the control panel as illustrated Press this button to turn on the appliance Press again and the button will bounce back The appliance is turned off FRONT VIEW POWER BUTTON 7 1 3 THE BUTTO...

Страница 18: ...tion the backlight of this button will be off Under the locked mode HEAT button is not available EN D To change flame color press the COLOR A button There are 3 colors to choose from red yellow and bl...

Страница 19: ...to choose from The indicator will show digital 1 to 9 and A to C when changing colors When you press the button for 3 seconds until you hear a beep the indicator will show digital 0 the flame color an...

Страница 20: ...60B CHFP 74B CHFP 74BS and CHFP 102B NOTE Control panel is the same as remote control G change flame speed press the SPEED button There are 5 speeds to choose from To The indicator will show V1 to V5...

Страница 21: ...B AND CHFP 74BS 7 4 3 CONTROL PANEL THAT IS USED FOR SCI AND CHFPN SERIES NOTE It is used for SCI 001 SCI 002 SCI 003 CHFPN 60 CHFPN 74 and CHFPN 102 21 7 4 1 CONTROL PANEL THAT IS USED FOR CHFPV 20 A...

Страница 22: ...k Add to connect WIFI and press Start to configure your device in 60 seconds D When configure succeed it opens e remote device list then click the icon to enter the software If you match several firep...

Страница 23: ...ching do not use abrasive cleaners 8 2 CLEANING GLASS DOOR Use only a damp cloth to clean glass door of the fireplace Do not use abrasive cleaners 8 3 SERVICING Except for installation and cleaning de...

Страница 24: ...4 5 6 7 8 9 10 11 12 9 0 REPLACEMENT PARTS 1 800 306 3829 STAND Take the replacement parts of CHFP 50B for example NOTE Care must be taken when removing and disposing of any broken glass or damaged c...

Страница 25: ...crews on the mirror glass CHP 007 Replace the LED circuit board CHP 001 There is something wrong with the circuit board Replace the circuit board CHP 002 Replace the transformer CHP 008 No warm air co...

Страница 26: ...es related to the reinstallation of a warranted part and such expenses are not covered by this warranty Notwithstanding any provisions contained in the Limited Warranty CAESAR FIREPLACE s responsibili...

Отзывы: