background image

 

 

 

 

 

 

 

 

 

 

 
 

 

 
CAEN  will repair or replace any product within the guarantee period if the Guarantor declares 
that the product is defective due to workmanship or materials and has not been caused by 
mishandling, negligence on behalf of the User, accident or  any abnormal conditions or 
operations. 
 
 

 
CAEN declines all responsibility for damages or 
injuries caused by an improper use of the Modules due 
to negligence on behalf of the User. It is strongly 
recommended to read thoroughly the CAEN User's 
Manual before any kind of operation. 
 

 
 

 

 

 
 

CAEN Technologies reserves the right to change partially or entirely the contents of this 
Manual at any time and without giving any notice. 
 

Disposal of the Product

 

The product must never be dumped in the Municipal Waste. Please check your local 
regulations for disposal of electronics products. 

  

 

 

MADE IN ITALY

 : We stress the fact that all the boards are made in Italy because in this globalized world, where getting the 

lowest possible price for products sometimes translates into poor pay and working conditions for the people who make them, at 
least you know that who made your board was reasonably paid and worked in a safe environment. (this obviously applies only 
to the boards marked "MADE IN ITALY", we can not attest to the manufacturing process of "third party" boards). 

Содержание NIM8304

Страница 1: ...Technical Information Manual NIM8304 14 April 2014 Revision n 3 12 slot 7U 5 2 Switching NIM Crate NPO 00121 09 N8304 MUTx 03...

Страница 2: ...s the right to change partially or entirely the contents of this Manual at any time and without giving any notice Disposal of the Product The product must never be dumped in the Municipal Waste Please...

Страница 3: ...PFC 18 3 3 MAINS VOLTAGE AND CONNECTION 19 3 4 POWER SUPPLY SPECIFICATIONS 19 3 4 1 Power Factor Correction Module 19 3 4 2 Power Modules 20 3 5 FAN TRAY CONTROL CONNECTOR SPECIFICATIONS 24 3 6 SENSE...

Страница 4: ...Tray USB RS232 connection 35 6 SOFTWARE OVERVIEW 36 6 1 FAN TRAY ETHERNET CONNECTION TO BE IMPLEMENTED 36 6 2 CONNECTION CONFIGURATION TO BE IMPLEMENTED 36 6 3 NIM8304_MANAGER STATUS SET WINDOW TO BE...

Страница 5: ...TOR 12V 23A 24V 11A 23 FIG 3 8 POWER MODULE RIPPLE AND NOISE AT LOAD 0 5 M WIRE 12V 23A 24V 11A 23 FIG 3 9 FAN TRAY CONTROL CONNECTOR 9 PIN DSUB FEMALE 24 FIG 3 10 SENSE SIGNAL CONNECTOR 37 PIN DSUB F...

Страница 6: ...1 MOD NIM8300 VERSIONS 7 TABLE 2 1 MOD NIM8304 TECHNICAL SPECIFICATIONS 9 TABLE 3 1 HIRSCHMANN CONNECTOR CABLING 19 TABLE 3 2 POWER FACTOR CORRECTION MODULE SPECIFICATIONS 19 TABLE 3 3 POWER MODULE 6...

Страница 7: ...WNIM8302150W 5 A 3 A 1 5 A 5U 12 slot std size 300 W WNIM8303300W 17 A 3 4 A 3 4 A 600 W WNIM8303600W 45 A 8 A 8 A WNIM8303600Y 20 A 15 A 4 A WNIM8303600Z 45 A 18 A 7U 12 slot std size 300 W WNIM83043...

Страница 8: ...d on a modularity concept and it has been divided into three detachable parts The Subrack Bin and NIM connector NIM 7U Bin 12 slot The Power Supply NIM switching Power supply 6V 90A 12V 23A 24V 11A Th...

Страница 9: ...tion 10 mV for 0 100 load change 6V 15 mV for 0 100 load change 12 V 15 mV for 0 100 load change 24 V Noise and ripple full load Output Max Typical 6V 10 mVpp 2 mVrms 6 0 mVpp 1 5 mVrms 12V 15 mVpp 2...

Страница 10: ...n date Revision User s Manual MUT Mod NIM8304 12 slot 7U 5 2 Switching NIM Crate 14 04 2014 3 NPO Filename Number of pages Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 10 2 2 Technical drawings Fig...

Страница 11: ...on date Revision User s Manual MUT Mod NIM8304 12 slot 7U 5 2 Switching NIM Crate 14 04 2014 3 NPO Filename Number of pages Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 11 Fig 2 2 Mod NIM8304 Rear...

Страница 12: ...itle Revision date Revision User s Manual MUT Mod NIM8304 12 slot 7U 5 2 Switching NIM Crate 14 04 2014 3 NPO Filename Number of pages Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 12 Fig 2 3 Mod NI...

Страница 13: ...on date Revision User s Manual MUT Mod NIM8304 12 slot 7U 5 2 Switching NIM Crate 14 04 2014 3 NPO Filename Number of pages Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 13 Fig 2 4 Mod NIM8304 side...

Страница 14: ...04 12 slot 7U 5 2 Switching NIM Crate 14 04 2014 3 NPO Filename Number of pages Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 14 Fig 2 5 Mod N8304 Smart NIM Fan Unit Front view Fig 2 6 Mod N8304 Sma...

Страница 15: ...04 2014 3 NPO Filename Number of pages Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 15 Fig 2 8 Mod N8304 Smart NIM Fan Unit Top view 2 3 Crate Backplane The backplane is equipped with 12 high qual...

Страница 16: ...slot 7U 5 2 Switching NIM Crate 14 04 2014 3 NPO Filename Number of pages Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 16 2 4 NIM8304 Bin Power connector Fig 2 10 Mod NIM8304 Bin power connectors...

Страница 17: ...NIM Power Supply is micro processor controlled switching power supply which provides extremely low noise output voltage Fig 3 1 Mod NIM8304 Power Supplies Front an Rear view the NIM8304 power supplies...

Страница 18: ...er Connector section Fig 3 3 Power Connector configuration 3 2 Power Factor Correction Module PFC The mains input includes a Power Factor Correction Module PFC with main filters soft start circuit and...

Страница 19: ...ge 3 3 Mains Voltage and Connection The Power supplies are equipped with a World mains input which works properly from 92Vac up to 264Vac and within a frequency range of 50 to 60Hz Before connecting t...

Страница 20: ...Voltage Accuracy 20 mV Minimum Load No Load Regulation 10 mV sense for 0 100 load change Transient Response Recovery 100 mV 25A current step change 6 ms for recovery to 1 of set voltage 25A to 0A cur...

Страница 21: ...Voltage 24V Current 11 A Rise Time 50 ms to 100 of voltage monotonic rise Ripple 15 mVpp 1 Typ 10 mVpp 1 see Fig 3 7 10 mVpp 2 Typ 5 mVpp 2 see Fig 3 8 Noise 2 mVrms 1 Typ 1 0 mVrms 1 see Fig 3 7 1 5...

Страница 22: ...ge 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 22 Fig 3 5 Power Module ripple and noise measured at the output connector 6V 90A Measured at load 0 5 m wire Load conditions full parallel X 330 F and 1 F...

Страница 23: ...Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 23 Fig 3 7 Power Module ripple and noise at output connector 12V 23A 24V 11A Measured at load 0 5 m wire Load conditions full parallel X 330 F and 1 F c...

Страница 24: ...g NIM Crate 14 04 2014 3 NPO Filename Number of pages Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 24 3 5 Fan Tray Control Connector Specifications Fig 3 9 Fan Tray Control Connector 9 pin DSUB fem...

Страница 25: ...he location of the connectors is shown in Fig 4 1 Their electromechanical specifications are listed here below USB DEVICE PORT Mechanical specifications USB B female connector Electrical specification...

Страница 26: ...ows CAN protocol 2 0B Transceiver PCA82C250 110 nodes at least guaranteed by the transceiver CAN connector 9 pin DSUB male TX RX of standard frames with 11 bit identifier Pinout of CAN bus connector i...

Страница 27: ...ata Pin 2 TXD Transmit Data Pin 3 RXD Receive Data Pin 4 EPWR Power from switch Pin 5 EPWR Power from switch Pin 6 RXD Receive Data Pin 7 EPWR Power from switch Pin 8 EPWR Power from switch Network Li...

Страница 28: ...vision User s Manual MUT Mod NIM8304 12 slot 7U 5 2 Switching NIM Crate 14 04 2014 3 NPO Filename Number of pages Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 28 Fig 4 6 FAIL signal timing Fail LED...

Страница 29: ...l phases of operation service and repair of this equipment Failure to comply with the safety precautions or warnings in this document violates safety standards of design manufacture and intended use o...

Страница 30: ...ons for initial inspection preparation for use and repackaging for shipment 5 2 1 Preparation for use In order to be operational the unit must be connected to an appropriate AC source The AC source vo...

Страница 31: ...d Trip off When the Crate Alarm is ON FAIL LED lamps timing described in Fig 4 6 FAIL Output signal is active see 4 1 5 Buzzer is active if enabled The Alarm reason is displayed on the FAN Unit OLED d...

Страница 32: ...us menu on the OLED display which is enabled via Crate turning on via local switch Crate turning on via remote interface The display is disabled only via local switch crate off 5 5 1 List of menu func...

Страница 33: ...Monitor Vout Value Current Value 6 24 V Monitor Vout Value Current Value 7 FAN status FAN speed FAN unit firmware release Serial Number FAN Unit Temperature of FAN Unit 8 ALARM Power Supply Status FA...

Страница 34: ...N8304 MUTx 03 NIM8304_REV3 DOC 44 34 Table 5 2 Mod NIM8304 FAN Tray Sub Menu Nr Display Description 10 6 V Set 11 6V Set 12 12 V Set 13 12 V Set 14 24 V Set 15 24 V Set 16 FAN Set 17 Power Supply Stat...

Страница 35: ...S232 and USB cannot be operated at the same time Maximum of 3 Ethernet connection are allowed 5 6 1 Configure Ethernet connection On a Local Area Network with DHCP Server In order to Obtain Configurat...

Страница 36: ...1 FAN Tray Ethernet connection to be implemented The provided program is NIM8304_Manager jar Fig 6 1 Mod NIM8304_Manager Open window 6 2 Connection configuration to be implemented Click on File connec...

Страница 37: ...e Number of pages Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 37 6 3 NIM8304_Manager Status Set window to be implemented Fig 6 4 Mod NIM8304_Manager Status Set window power off Click on Power to s...

Страница 38: ...can be achieved by Using the RS232 interface to connect one Mod NIM8304 FAN Tray system to a VT100 like terminal or to a standard PC running a terminal emulator program Using the USB interface to con...

Страница 39: ...014 3 NPO Filename Number of pages Page 00121 09 N8304 MUTx 03 NIM8304_REV3 DOC 44 39 Digit CAEN Cr the following menu opens Fig 6 7 Mod NIM8304 Terminal Menu window Update option is available only wi...

Страница 40: ...protocol by using a TFTP Trivial File Transfer Protocol Server Software 1 In order to add a file in the system flash memory via TFTP follow this procedure check if the system is connected via TCP IP...

Страница 41: ...window 2 In order to update the Fan Unit firmware press F the next menu will be as follows Fig 6 12 Mod NIM8304 Fan Unit Firmware Update window Type the IP Address of the computer where the image fil...

Страница 42: ...PAR NAME Cr Readout channel name ex 6V CMD MON CH X PAR VMIN Cr Readout minimum value of the voltage Monitor CMD MON CH X PAR VMAX Cr Readout maximum value of the voltage Monitor CMD MON CH X PAR VRES...

Страница 43: ...value Fan Speed 2 RPM CMD MON CH 6 PAR FAN3 Cr Readout value Fan Speed 3 RPM CMD MON CH 6 PAR FUFREL Cr Readout of the FAN UNIT Release Firmware CMD MON CH 6 PAR FUTEMP Cr Readout value of the FAN UN...

Страница 44: ...e on PS 70 C Bit 4 PS OVC 1 PS in Over Current Bit 5 PS OVV UNV 1 PS voltage out of range Bit 6 8 N C Bit 9 FAN ON OFF 1 FAN ON 0 FAN OFF Bit 10 Fan 1 Fail 1 Fan 1 Speed 10 or 10 nominal value Bit 11...