CAEN
Electronic
Instrumentation
DT54xx
USB
High
Voltage
Power
Supply
27
status:
status
is
TRUE
(X)
if
an
error
occurred
or
FALSE
(checkmark)
to
indicate
a
warning
or
that
no
error
occurred.
Right
‐
click
the
error
in
control
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
code:
code
is
the
error
or
warning
code. Right
‐
click
the
error
in
control
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
source:
source
describes
the
origin
of
the
error
or
warning. Right
‐
click
the
error
in
control
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
VISA
resource
name
BoardHandle
is
a
reference
to
an
open
board.
get
more?
:
If
get
more?
is
TRUE,
get
more
constant
information
releated
a
this
parameter
and
return
these
in
a
cluster
.
The
default
is
FALSE.
If
is
TRUE
the
VI
require
more
time
to
execution.
error
out:
error
out
passes
error
or
warning
information
out
of
a
VI
to
be
used
by
other
VIs.
Right
‐
click
the
error
out
control
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
status:
status
is
TRUE
(X)
if
an
error
occurred
or
FALSE
(checkmark)
to
indicate
a
warning
or
that
no
error
occurred.
Right
‐
click
the
error
out
control
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
code:
code
is
the
error
or
warning
code. Right
‐
click
the
error
out
control
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
source:
source
describes
the
origin
of
the
error
or
warning. Right
‐
click
the
error
out
control
on
the
front
panel
and
select
Explain
Error
or
Explain
Warning
from
the
shortcut
menu
for
more
information
about
the
error.
VISA
resource
name
out
ISet
constants
array
of
cluster
with
constant
information
for
this
parameter.
VSet
constant
Min
Max
Digits
of
precision
ISet
value
(uA)
CAEN
DT54XX.lvlib:Close.vi
This
function
terminates
the
software
connection
to
the
instrument.
Connector
Pane
Controls
and
Indicators
VISA
resource
name
A
reference
to
the
instrument
in
use.
The
reference
to
the
resource
name
is
created
in
the
Initialize
VI.
Therefore,
before
calling
this
VI,
you
need
to
call
the
Initialize
VI.
To
run
this
VI
interactively,
select
the
previously
initialized
resource
name
from
the
pull
‐
down
menu.
To
run
this
VI
programmatically,
wire
the
VISA
resource
name
out
terminal
of
the
Initialize
VI
to
subsequent
VISA
resource
name
input
terminals.
You
chain
instrument
driver
VIs