- skID Technical Information Manual
15
RF Power Up (mW)
Through the
RF Power Up
you can set the power level emitted by the reader. The
RF Power Up
is an
editable field and the default value is 500 mW. Accepted values are included in the range 0÷500. The
RF
Power Up
is expressed in mW
Note that, when the reader is configured in the EASY2READ profile, to set the
RF Power Up
you can also
use the CAEN RFID Easy Controller Application or the
SetPower
function of the SDK (Software
Development Kit) library.
EPCC1G2 Parameters
Q:
Q
parameter is useful for the optimization of the inventory efficiency. As a rule of thumb, if you
have to read a huge population of tags you need to select a high value for the Q parameter,
otherwise you can select a lower value. For more information on Q parameter see EPC Class1
Gen2 protocol specification [RD1]. The default value is 6, accepted values are included in the range
0÷15.
Q
parameter is an editable field.
Session:
the
Session
used by the anticollision algorithm. The reader chooses one of four sessions
available (S0, S1, S2 and S3) and inventories tags within that session. For more information on
session see EPC Class1 Gen2 protocol specification [RD1]. Default value is EPC C1G2 Session =
S0. You can change the default value using the drop-down menu.
Target
A or B. For more information on
target
see EPC Class1 Gen2 protocol specification [RD1].
Default value is
target
= A. You can change the default value using the drop-down menu.
Selected:
ALL, NOT selected, selected. For more information on
Selected
see EPC Class1 Gen2
protocol specification [RD1]. Default value is
selected
= ALL. You can change the default value
using the drop-down menu
Содержание R1280I
Страница 1: ...1 TECHNICAL INFORMATION MANUAL Revision 0 0 22 February 2021 skID R1280I Mini Sled RAIN RFID Reader...
Страница 29: ...EASY2READ PROFILE skID Technical Information Manual 29 4 Click on Add reader...
Страница 30: ...EASY2READ PROFILE skID Technical Information Manual 30 5 Click on Bluetooth in the Connection Type window...
Страница 33: ...EASY2READ PROFILE skID Technical Information Manual 33 9 Click on Start Inventory...
Страница 34: ...EASY2READ PROFILE skID Technical Information Manual 34 10 A list of the read tags is shown...
Страница 47: ...EASY2READ PROFILE skID Technical Information Manual 47 3 Launch the CAEN RFID Easy Controller for iOS App...
Страница 48: ...EASY2READ PROFILE skID Technical Information Manual 48 4 Click on Menu Connect...
Страница 49: ...EASY2READ PROFILE skID Technical Information Manual 49 5 Click on icon...
Страница 55: ...HID PROFILE skID Technical Information Manual 55...