Polarity Inverters
–
User’s Ma
nual
19
2.5
Connections
Turn off the input power before making or changing any rear
panel connection. Ensure that all connections are securely
tightened before applying power.
The connections mentioned in
Section 1.2
WPOLINV200XA
Figure 8:
Rear panel of the WPOLINV200XA model.
The main parts on the rear panel of the
WPOLINV200XA
polarity inverter are listed
: Rear panel of the WPOLINV200XA model.
:
6
- POWER CABLES from the power unit have to be connected to the DC-IN and
the load to DC-OUT. DC-IN left connector corresponds to DC-OUT left
connector in case of direct polarity, otherwise it corresponds to DC-OUT
right connector. The same is true for DC-IN right connector, which
corresponds to DC-OUT right one if the polarity is direct;
7
-
CONTROL AND MONITORING
connector (C1);
8
-
EARTH
stud connection.
WARNING
6
7
8