Page
4
of
5
Doc
G09 Rev 1
Date
27102020
Admitted Deflection
The maximum admitted deflection measured in the middle must be L/200 (L =
shelf length).
Front
f =
≤
𝟏𝟏
L
𝟐𝟐𝟐𝟐𝟐𝟐
Important:
Always work within the safe working loads (SWL) for the shelving.
SWL loads can be found in the technical manuals for your particular system.
Constant inspections of
the structure can avoid
personal injury and/or
property damage and
can limit the interruption
of the productive
activity.
It is advisable to inspect
the structures and look
for possible anomalies,
which may affect the
proper settling of the
structure and cause
accidents to people
and properties.
If hazardous issues are
discovered, it is
advisable to unload the
shelving immediately
and pay the utmost
attention to avoid
personal injury and/
or property damage. If
necessary, contact
CAEM customer service
to examine the situation
and solve the problem.
Item
Recommended Frequency of checks
Uprights
6 Months
Shelves
6 Months
Bases
6 Months
Brackets
6 Months
Back Panel
6 Months
Shelving Verticality
6 Months
Shelving Levelling
6 Months
Position of Shelves
6 Months
Weight on Shelves
Each time a product is changed
Rust Presence
12 months