©2023 CAE 905K600152 v1.4
85
Care and Maintenance
C
ARE
AND
M
AINTENANCE
Maintaining the simulator requires careful treatment of electronic and mechanical components. After
use, make sure all components are properly handled and correctly removed or placed into storage.
Note:
Many hardware components of the simulator and the Instructor Workstation are not user-
serviceable. Contact CAE Healthcare Customer Support for any questions and concerns regarding
hardware maintenance.
General Simulator Care
• Avoid the use of writing instruments and sharp objects near the patient simulator to
prevent tears or unattractive markings in or on the skin.
• A mild detergent and warm water will remove most marks and stains. Gently rub the
soiled area with a soft cloth. DO NOT use ABRASIVE soaps or pads.
• Lubricate airway adjuncts, urinary catheters, nasogastric tubes, and enema tubes with
silicone spray prior to insertion. DO NOT use water-based lubricant.
• Prior to using moulage of any kind, and to make cleansing the simulator’s skin easier,
lightly apply petroleum jelly to the simulator’s skin, followed by a light amount of talcum
powder (unscented baby powder).
• If the IV sites have been used, remove the fluid as described in the breakdown procedure.
Failure to drain and clean the systems may cause problems with the system.
• If the IM injection site(s) have been used, remove the fluid from the sponge inside the
injection site pad as described in the breakdown procedure.
Breakdown
To keep the simulator in good condition, follow the breakdown procedures below before storage.
CAUTION
Do not attempt to open or repair any simulator components without authorization from CAE
Customer Support. Doing so may void the warranty.
Break down the Juno Simulator
1
Clean the manikin
2
Drain and clean the rectum
3
Drain and flush the IV
4
Maintain the IM injection site
5
Power off the instructor tablet
6
Power off the manikin (Live and Complete configurations only)
Содержание Juno
Страница 1: ...User Guide Your worldwide training partner of choice...
Страница 32: ...Equipment Overview 26 2023 CAE 905K600152 v1 4 CAEJuno THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 36: ...30 2023 CAE 905K600152 v1 4 CAEJuno THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 46: ...Setup 40 2023 CAE 905K600152 v1 4 CAEJuno NIBP Connections...
Страница 56: ...Juno Features 50 2023 CAE 905K600152 v1 4 CAEJuno THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 90: ...Using Juno 84 2023 CAE 905K600152 v1 4 CAEJuno THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 100: ...Appendix A Recommended Clinical Supplies 94 2023 CAE 905K600152 v1 4 CAEJuno THIS PAGE INTENTIONALLY LEFT BLANK...