Содержание AP-C710S

Страница 1: ...Table of Contents 1 Safety Precautions 3 Operating Precautions 3 Installing the Unit 4 Parts and Functions 6 Installing the Deodorizing Dust Collecting Anti Bacterial Filter 7 How to Operate 8 Mainten...

Страница 2: ...rvice center Do not use the unit in the following locations In areas with flammable gas or places with metal dust It may lead to the gas catching on fire igniting or fuming due to dust being sucked in...

Страница 3: ...in the outlet may cause electric shock or injury Do not sit or stand on the unit Falling down from the unit or toppling may cause injury or malfunction Do not put the unit in unstable locations If th...

Страница 4: ...or malfunction of the unit Do not use the unit near a TV or radio It may cause distortion of video images or noise Place the unit at least 1m away from a TV or radio Also using the same wall outlet as...

Страница 5: ...culates Cover stopper ones on the left and right side Odor and dust monitor indicates the room air quality in blue yellow and red page 5 Control panel page 7 Handle Ones on the left and right side Use...

Страница 6: ...ng maintenance such as removing the filter to replace it unplug the power plug and avoid looking directly into the light The photocatalytic lamp will turn off if the deodorizing dust collecting anti b...

Страница 7: ...e unit Align the on the filters with the on the unit as shown in the figure below then insert the filters all the way to the bottom of the unit Installing the Deodorizing Dust Collecting Anti Bacteria...

Страница 8: ...light up then turn off Press the power button After it beeps all of the buttons on the control panel along with the automatic indicator odor and dust monitor and the air inlet lamps will light up If...

Страница 9: ...from the unit with a soft cloth Remove dust from the air inlet and air outlet with a vacuum cleaner or use a soft cloth to wipe it off When it is extremely dirty use a cloth with watered down neutral...

Страница 10: ...sensor Air outlet Air inlet Use a dry cotton swab to wipe the moisture on the sensor air inlet and air outlet Close the dust sensor cover 1 2 3 4 5 1 2 3 Install new filters See Installing the Deodor...

Страница 11: ...llecting anti bacterial filter is installed properly and firmly close the top cover 6 The odor and dust monitor remains red even though the air is not dirty The dust and odor sensors may react to chan...

Страница 12: ...oes not change in accordance with the indications of the odor and dust monitor The operation does not stop even though the air is clean The unit will continue to operate with a low air volume even if...

Страница 13: ...h 423 Depth 297 Height 714 including protrusions Weight kg 18 including filters Power cord length m 1 8 Accessories Instruction manual warranty card deodorizing dust collecting anti bacterial filter 2...

Страница 14: ......

Страница 15: ......

Страница 16: ...JA 00013 0201 http en cado co jp...

Отзывы: