Symptom

Problem

Solution

Breaker trips immediately
upon energizing heater.

Heater fan operates,
but does not discharge
warm air.

Heater will not shut off.

Heater discharges smoke
or emits a burnt odor.

Element heats for a
moment without the fan
turning, then immediately
stops heating.

Heater does not run.

Troubleshooting Chart

1. Incorrect supply voltage.
2. Overloaded circuit.

3. A short circuit exists in the supply or

heater wiring.

4. Defective circuit breaker.

1. Insufficient element temperature.
2. Incorrect supply voltage.
3. Element has failed.
4. (Model CT only) One of the heater

units must be reset.

1. Heat loss from room is greater than

heater capacity.

2. Defective thermostat.

3. Thermostat wired incorrectly to heater.

1. Dust, lint or other matter has

accumulated inside heater.

1. Defective motor or internal connection.
2. Fan or motor jammed.

1. Thermostat set too low.

2. Heater has tripped the manual

high-temperature reset control.

3. Heater has tripped the secondary

over-temperature switch.

4. Power not on at the circuit breaker.
5. Broken or poorly connected wire(s)

to heater.

6. Defective thermostat.

1. Verify that supply voltage matches the heater rating.
2. The total amperage of all heaters on a branch circuit must not be more than

80% of the amperage rating of the circuit breaker and supply wire ratings.
Use a lower wattage heater, or reduce the number of heaters on the circuit.

3. Shorted supply or heater wires may be accompanied by severe sparking.

Inspect all supply and heater wiring insulation for damage. Do not reset the
circuit breaker until all electrical shorts have been repaired.

4. Replace the circuit breaker.

1. Allow a few moments for element to reach operating temperature.
2. Verify that supply voltage matches the heater rating.
3. Replace element.
4. CT models have two heating units with independent over-temperature

controls. One of the high-temperature reset switches may trip and cut power
to one of the heating units, while the other remains running, resulting in only
half output. Reset the heater unit that is not operating (see “Operation &
Maintenance” section for instructions).

1. Close doors and windows. Provide additional insulation, or install a higher

wattage heater or multiple heaters if necessary. (If your circuit is rated for
more capacity.)

2. Adjust thermostat to its lowest setting. If heater continues to run (allow two

minutes for the thermostat to respond), and room temperature is greater than
50 degrees; replace the thermostat.

3. Refer to thermostat documentation and correct wiring.

1. Clean heater (see “Operation & Maintenance” section for instructions).

1. Heater or fan motor requires replacement.
2. Remove obstruction and press heater reset button (after allowing the unit to

cool). Test heater operation--if reset button has been pressed (be sure to
listen and feel for a click indicating it has been reset), but heater does not run,
heater requires repair or replacement.

1. Adjust thermostat to a higher temperature until heater operates (see Problem #6

if the problem persists).

2. Press the manual reset button (see “Operation & Maintenance” section for

instructions).

3. A severe over-temperature condition has occurred. Repair or replace heater.

4. Turn on the correct circuit breaker in the main panel.
5. Turn off power at circuit breaker. Check supply wire continuity and proper

connection to heater wires.

6. The entire heater, or any of its components may be checked for continuity

to determine the cause of any problems. Repair or replace the heater.

Maintenance

For more effective and safer operation and to prolong the life of the heater,
read the Owner’s Guide and follow the maintenance instructions included
with each heater. Failure to properly maintain the heater will void any
warranty and may cause the heater to function improperly. Warranties are
non transferable and apply to original consumer only. Warranty terms are
set out below.

LIMITED ONE-YEAR WARRANTY:

Cadet will repair or replace any Cadet

product, including thermostats, found to be defective within one year after
the date of purchase.

Extended Product Warranty

LIMITED TWO-YEAR WARRANTY:

Cadet will repair or replace any Com-

Pak

TM

Plus (C), Com-Pak

TM

Twin Plus (CT), series element or motor found to

be defective within two years after the date of purchase.

These warranties do not apply:

1. Damage occurs to the product through improper installation or incorrect

supply voltage;

2. Damage occurs to the product through improper maintenance, misuse,

abuse, accident, or alteration;

3. The product is serviced by anyone other than Cadet.
4. If the date of manufacture of the product cannot be determined;
5. If the product is damaged during shipping through no fault of Cadet.

6. CADET’S WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT AS SET

OUT HEREIN. CADET SHALL NOT BE LIABLE FOR DAMAGES SUCH AS
PROPERTY DAMAGE OR FOR CONSEQUENTIAL DAMAGES AND/OR
INCIDENTAL EXPENSES RESULTING FROM BREACH OF THESE WRITTEN
WARRANTIES OR ANY EXPRESS OR IMPLIED WARRANTY.

7. IN THE EVENT CADET ELECTS TO REPLACE ANY PART OF YOUR CADET

PRODUCT, THE REPLACEMENT PARTS ARE SUBJECT TO THE SAME
WARRANTIES

AS

THE

PRODUCT.

THE

INSTALLATION

OR

REPLACEMENT PARTS DOES NOT MODIFY OR EXTEND THE
UNDERLYING WARRANTIES. REPLACEMENT OR REPAIR OF ANY CADET
PRODUCT OR PART DOES NOT CREATE ANY NEW WARRANTIES.

8. The warranties give you specific legal rights, and you may also have

other rights which vary from state to state. Cadet neither assumes, nor
authorizes anyone to assume for it, any other obligation or liability in
connection with its products other than as set out herein.

If you believe your Cadet product is defective, please, contact Cadet
Manufacturing Co. at 360-693-2505, during the warranty period, for
instructions on how to have the repair or replacement processed. Warranty
claims made after the warranty period has expired will be denied.
Products returned without authorization will be refused.

Parts and Service

Visit support.cadetco.com for information on where to obtain parts and service.

©2007 Cadet Manufacturing Co.

Printed in U.S.A. Rev. 11/07 #720080

5

All manuals and user guides at all-guides.com

Содержание The Com-Pak Plus C051 reset

Страница 1: ...as hot and arcing or sparking parts inside Do not install heater in any area where combustible vapors gases liquids or excessive lint or dust are present 9 WARNING Burn Hazard This heater is hot when in use To avoid burns do not let bare skin touch hot surfaces Use extreme caution when any heater is used by or near children or invalids and whenever the heater is left operating unattended 10 WARNIN...

Страница 2: ... output Hooking a 120 volt heater to a 240 volt power supply will destroy the heater Connecting your heater to an incompatible power supply will void the warranty Part One PLACEMENT Install The Com Pak Plus Model C vertically recommended or horizontally Model C may be installed in the ceiling for models up to 1500W maximum See ceiling mount instructions The Com Pak Twin Plus Model CT must be insta...

Страница 3: ...ical shock burns or possible death STEP 1 Mount the Wall Can Route supply wire from circuit breaker to thermostat to wall can Models with a built in thermostat are not recommended for ceiling mount Remove a knockout in the wall can and attach the supply wire with a strain relief connector leaving 10 inches wire lead for later use See Figure 3 Connect supply ground wire to grounding pigtail in wall...

Страница 4: ...e with screws 9 Turn thermostat to desired setting 10 Turn power back on at the electrical panel board About the Heater Temperature Limiting Controls The heater is protected by two temperature limiting controls for Model CT four controls are used The first is a high temperature manual reset limit control designed to open the heater circuit when excessive operating temperatures are detected The pro...

Страница 5: ...res repair or replacement 1 Adjust thermostat to a higher temperature until heater operates see Problem 6 if the problem persists 2 Press the manual reset button see Operation Maintenance section for instructions 3 A severe over temperature condition has occurred Repair or replace heater 4 Turn on the correct circuit breaker in the main panel 5 Turn off power at circuit breaker Check supply wire c...

Страница 6: ...mación Verifique que todos los cables de suministro eléctrico sean del mismo voltaje que el calentador 3 Todo trabajo y materiales eléctricos deben cumplir con el Código Eléctrico Nacional NEC por su sigla en inglés con la Ley de Seguridad y Salud Ocupacional OSHA por su sigla en inglés y con todos los códigos estatales y locales 4 Conecte el alambre de tierra en espiral de cobre que viene en la c...

Страница 7: ... circuito al termostato al calentador Para los modelos con termostato incorporado colocar el cable de suministro desde el interruptor de circuito al calentador Quitar una de las piezas desmontables y colocar el cable de suministro con un conector de alivio de tensión dejando el conector de cable de 10 para poder utilizarlo más tarde Ver la Figura 3 Conectar el cable de suministro a tierra con el c...

Страница 8: ...All manuals and user guides at all guides com ...

Страница 9: ...All manuals and user guides at all guides com ...

Страница 10: ... 2007 Cadet Manufacturing Co Printed in U S A Rev 11 07 720080 All manuals and user guides at all guides com ...

Отзывы: