SHELL - BREEZE
24
PROBLEM
CAUSE
SOLUTION
INTERVENTION
The stove's smoke
duct produces
condensation
Low smoke tempe-
rature
Check that the flue is not clogged.
Increase stove power to minimum (pellet drop and fan revs).
Install condensation collection cup.
Stove running and
display showing
"SERVICE"
Routine maintenan-
ce alert (it does not
block the system)
When this flashing message appears upon start-up, it means that
the preset operating hours have elapsed before maintenance.
Contact the service centre.
9
TECHNICAL DATAS
9.1
REPAIR INFORMATION
Now we give some instructions for the Authorized Technician to take into consideration to have access to stove mechanical com-
ponents.
• For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change with the aid of a
screwdriver for opening the shutter (see
Fig. 49
).
Fig. 49 - Shutter with fuses to remove
Proceed as follows:
• Remove the frame (see the dedicated chapters).
• After these operations you can have access at the following components: geared motor, ignition plug, ambient fan, fume fan,
ambient probe, fume probe, thermostat, electronic board, pressostat.
• For cleaning or replacemente of the auger it is necessary to unscrew the three bolt of the geared motor and to extract it, un-
screw the two screws lying under the geared motor (vedi
Fig. 50
), of the auger, remove the hand rejector inside the hopper
and then unscrew the inner bolt of the auger. (vedi
Fig. 51
).To assembly proceed at the contrary.
Fig. 50 - Remove the screws
Fig. 51 - Remove the screw