
42
AQUOS - IBIS - IDRON
EN
13.17
FEED SCREW (SEE SECTION D SETTINGS MENU PAGE 30)
Allows to fill the pellets loading system. It can only be activated with the boiler switched off, it displays an 180”
countdown after which the feed screw stops automatically, as when exiting the menu.
13.18
COMPONENTS TEST (SEE SECTION M SETTINGS MENU PAGE 30)
It can only be carried out with the boiler switched off, it allows to select the components to be tested:
•
Spark plug: it is turned on for a fixed time of 1 minute during which the panel displays the countdown seconds.
•
Feed screw: it is powered for a fixed time of 1 minute during which the panel displays the countdown seconds.
•
Extractor: it is activated at 2500 rpm for a fixed time of 1 minute during which the panel displays the countdown seconds.
•
Exchanger: it allows to carry out the test in V5 for a fixed time of 1 minute during which the panel displays the
countdown seconds.
•
Pump: it is activated for a fixed time of 10 seconds during which the panel displays the countdown.
•
3 way: the 3 way valve is activated for a fixed time of 1 minute during which the panel displays the countdown seconds.
14
SAFETY DEVICES AND ALARMS
14.1
SAFETY DEVICES
The product is supplied with the following safety devices
14.2
PRESSURE SWITCH
Monitors pressure in the smoke duct. It is designed to shut down the pellets feed screw in the event of an
obstructed flue or significant back-pressure. (wind)
14.3
SMOKE TEMPERATURE PROBE
Detects the temperature of the smoke, thereby enabling start-up or stopping the product when the temperature
drops below the preset value.
14.4
CONTACT THERMOSTAT IN THE FUEL HOPPER
If the temperature exceeds the preset safety level, it immediately shuts down boiler operation.
14.5
CONTACT THERMOSTAT IN THE BOILER
If the temperature exceeds the preset safety level, it immediately shuts down boiler operation.
14.6
WATER TEMPERATURE PROBE
If the water temperature approaches the shutdown temperature (85°C) the probe makes the boiler perform the
“OFF Stand-by” automatic shutdown.
14.7
ELECTRICAL SAFETY
The product is protected against sudden current surges by a main fuse in the power supply panel on the rear
part of the product. Other fuses that protect the electronic boards are found on the latter.
14.8
SMOKE FAN
If the fan stops, the electronic board promptly shuts off the pellets supply and an alarm message is displayed.
14.9
GEAR MOTOR
If the gear motor stops, the boiler will continue to run until the flame goes out due to lack of fuel and until a
minimum level of cooling is reached.
14.10
TEMPORARY POWER CUT
If the power cut lasts less than 10” the boiler returns to its previous operating status; if it lasts more it carries out a
cooling/restart cycle.
14.11
FAILED START-UP
If during ignition no flame develops, the boiler will go into alarm condition.
Содержание IDRON 22 AIRTIGHT
Страница 13: ...13 AQUOS IBIS IDRON EN Fig 7 Ibis 11 dimensions ...
Страница 14: ...14 AQUOS IBIS IDRON EN Fig 8 Ibis 15 Ibis 22 Ibis 22 H2O dimensions ...
Страница 15: ...15 AQUOS IBIS IDRON EN Fig 9 Idron 11 dimensions ...
Страница 16: ...16 AQUOS IBIS IDRON EN Fig 10 Idron 15 Idron 22 Idron 22 H2O dimensions ...
Страница 36: ...36 AQUOS IBIS IDRON EN Fig 32 Configuration 3 Fig 33 Configuration 4 ...
Страница 53: ...NOTE ...
Страница 54: ...NOTE ...
Страница 55: ...NOTE ...