40
AQUOS - IBIS - IDRON
EN
13.6
PROGRAMMING EXAMPLES:
P1
P2
on
off
day
on
off
day
08:00
12:00
mon
11:00
14:00
mon
Boiler on from 08:00 to 14:00
on
off
day
on
off
day
08:00
11:00
mon
11:00
14:00
mon
Boiler on from 08:00 to 14:00
on
off
day
on
off
day
17:00
24:00
mon
00:00
06:00
tue
Boiler on from 17:00 on monday to 06:00 on tuesday
13.7
NOTES FOR TIMER OPERATION
• Start-up with the timer always takes place with the last temperature and ventilation settings (or with default
20°C and V3 settings in the event they have never been changed).
• Start-up time ranges from 00:00 a 23:50
• If the shutdown time is not already memorised, it proposes a start-up time in + 10 minutes.
• A timer programme switches the boiler off at 24:00 of one day and another programme switches it on at 00:00
of the next day: the boiler stays on.
• A programme proposes a start-up and shutdown in times included within another timer programme: if the
boiler is already on, start will not have any effect, while OFF will switch it off.
• In the boiler on and timer active condition, press the OFF key and the boiler will switch off, it will switch on
automatically at the next time set on the timer.
• In the boiler off and timer active condition, press the ON key and the boiler will switch on, it will switch off at
the time set on the active timer.
13.8
AUTO ECO MODE (SEE SECTION F-G SETTINGS MENU PAGE 30)
To activate the “Auto Eco” mode and adjust the time refer
SETTINGS MENU page 30
.
The possibility to adjust the “ECO shutdown t” comes from the need to ensure proper operation in the various
rooms the boiler can be installed in and prevent continuous shutdowns and start-ups in the event the temperature
is subject to sudden changes (air currents, poorly insulated rooms, etc.).
The ECO shutdown procedure is activated automatically when all the power demand devices involved in the
“system configuration” are satisfied: room probe/external thermostat, flow switch, puffer thermostat/ntc (10 kΩ
ß3435) or boiler thermostat/ntc (10 kΩ ß3435). If all devices present are satisfied the “ECO shutdown t” time
decrease starts (by default 10 minutes, it can be changed within the “Settings menu”). During this stage the
panel displays ON with a small flame and alternately Chrono (of active) - Eco active. The minutes indicating the
countdown for the Eco Stop are shown at the top of the display. The flame goes into P1 and stays there until the
programmed “Eco shutdown t” time has elapsed and if the conditions are still satisfied, it goes into the shutdown
stage. The ECO switch off countdown resets if one of the devices boosts power again.
When switch off starts the panel displays: Off - Eco Active - small flashing flame.
Once the boiler has reached the off condition, the panel displays OFF-ECO with the extinguished flame symbol.
To restart from ECO the following conditions must be satisfied simultaneously:
• Power demand
• After 5 minutes from the beginning of shutdown.
• TH2O < TSetH2O.
•
If the domestic hot water (DHW) demands power - if envisaged - the first 5’ are ignored and the boiler restarts
as needed.
NOTE: In configuration 4 - 5 the Auto Eco mode is enabled automatically. Even when one sets the “summer”
function in configuration 2 - 3 it is enabled automatically. In the cases where it is designed to be active, it is not
possible to deactivate the mode.
13.9
SLEEP FUNCTION (MAIN MENU)
The sleep function is activated only when the boiler is switched on and allows to quickly set a time at which the
product must switch off.
To set the Sleep function act as follows:
Содержание IDRON 22 AIRTIGHT
Страница 13: ...13 AQUOS IBIS IDRON EN Fig 7 Ibis 11 dimensions ...
Страница 14: ...14 AQUOS IBIS IDRON EN Fig 8 Ibis 15 Ibis 22 Ibis 22 H2O dimensions ...
Страница 15: ...15 AQUOS IBIS IDRON EN Fig 9 Idron 11 dimensions ...
Страница 16: ...16 AQUOS IBIS IDRON EN Fig 10 Idron 15 Idron 22 Idron 22 H2O dimensions ...
Страница 36: ...36 AQUOS IBIS IDRON EN Fig 32 Configuration 3 Fig 33 Configuration 4 ...
Страница 53: ...NOTE ...
Страница 54: ...NOTE ...
Страница 55: ...NOTE ...