17
KOBE - FENICE - SPARK - INDACO - PRINCE
pre-heating starts. After some seconds the feed screw loads pellets and the resistance pre-heating continues. When the tem-
perature is high enough (after about 5-8 minutes), ignition is considered to be completed.
• Once the ignition step is complete, the stove moves into operating mode and shows the selected heat output, the ambient
temperature and the
big flame
(see
Fig. 11
).
• If the ambient temperature value exceeds the limit set on the button panel in the temperature set, the heat output is brought
to its lowest value and the
small flame
is shown (see
Fig. 12
). When the ambient temperature decreases below the set tem-
perature, the stove goes back to the set output.
Fig. 11 - Big flame
Fig. 12 - Small flame
8.7
FAILED IGNITION
If pellets should not ignite, the lack of ignition will be signalled by the A01 "No Ignition" warning.
If the ambient temperature is below 5°C, the resistance may not heat up enough to guarantee the pallet ignition. In this case,
remove the unburned pellets from the burning pot and restart ignition.
Too much pellets in the burning pot, or humid pellet, or sooty burning pot make ignition difficult and create dense white smoke
which is harmful to health and can cause explosions on the combustion chamber. It is therefore necessary not to stand in front of
the stove during ignition stage if dense white smoke is present.
If after some months the flame appears weak and/or orange colored or the glass tends to blackens and the
burning pot to become encrusted, clean the stove, clean the fume conduit and the chimney flue.
ATTENTION!
Make sure pellets and ash have not accumulated in the brazier due to failed ignition. If the brazier is not clea-
ned before reattempting, there is the risk of further failed ignitions and even explosions in some cases.
8.8
SWITCH OFF (ON PANEL: OFF WITH FLASHING FLAME)
If the shutdown key is pressed or if there is an alarm signal, the boiler goes into the thermal shutdown phase which entails the
automatic execution of the following stages:
• Pellet loading is stopped.
• The room fan continues to operate until the requested temperature is reached.
• The flue fan is set to its highest value, which it keeps until the requested temperature is reached, plus a safety time of 10
additional minutes. After that, if the fume temperature has decreased below the switch off threshold, it stops, otherwise the
cooling process goes on.
• If the stove has switched off normally, but owing to thermal inertia, the fume temperature goes over the threshold again, the
switch off process is reactivated until the temperature decreases again.
8.9
POWER FAILURE
• After a black-out lower than 10 seconds, the stove turns back to the power which was settled.
• After a black-out of more than 10 seconds, the stove enters the during shutdown. Completed this phase, it starts automatically
up with the different phases.
8.10 ADJUSTMENTS MENU
To access the adjustments menu act as follows:
• Press the + - keys
• Scroll with the <> arrows and select “Set Room T ” or “Air Fan Speed 1” or “Air Fan Speed 2” or “Comfort Mode” or "Fire"
• Press “menu” to access the selected option.
• Modify with the + - keys.
• Press “menu” to confirm and “esc” to exit.