LUCE -  ELLE - ARCO

Fig. 5 - Anti-wind chimney pots

Fig. 6 - Reflux area

3.6 

MAINTENANCE

•  The fumes extraction pipes (fumes c chimney flue + chimney pot) must always be cleaned, scrubbed and checked 

by an expert stove-repairer, in compliance with current regulations, with the instructions of the stove-manufacturer and the 

directives of your insurance company.

•  In case of doubts, please follow the most restrictive regulations.

•  Have your chimney flue and chimney pot checked and cleaned by an expert chimney sweep at least once a week. The chimney 

sweep has to release a written declaration about the security of the system.

•  Not cleaning compromise safety.

COMBUSTION AIR

4.1 

AIR INLET

It is mandatory to provide an adequate external air inlet that supplies the combustion air required for the product to work properly. 

The flow of air between the outside and the installation room can take place with a free air inlet or by channelling the air directly 

to the outside

 (***)

.

The free air inlet must be:

•  be made at floor level and in any case not higher than the height of the appliance;

•  always be protected with an outer grille and in such a way that it cannot be obstructed by any object;

•  have a minimum total free area of 80 cm

2

 (net of the grille);

The presence of other suction devices (e.g.: vmc, electric fan for stale air extraction, kitchen hood, other stoves, etc.), in the same 

room,or in communicating rooms of the same housing unit, could cause negative pressure in the room. In this case, with the 

exception of sealed installations, one must verify that, with all the equipment on, no more than 4 Pa of negative pressure is created 

inside the installation room with respect to the outside. If necessary, increase the air inlet section.

It is possible to duct the air required for combustion to the outside by connecting the external air inlet directly with the combustion 

air inlet which is usually found on the back of the appliance.

The external ducted air vents must be:

•  made close to the floor and anyway not higher than the appliance

•  protected by a grille that guarantees a clear surface equal to the cross-section of the duct and made so that it cannot be ob-

structed by any object

•  The air vent can be made directly on a wall of the installation room communicating with the outside, or indirectly in adjacent 

rooms that permanently communicate with the installation room, according to that set forth by standards in force.

The duct must comply with the following dimensions (each 90° bend is equivalent to one linear metre):

(***)

 

In the event the combustion air is ducted on unsealed products, still verify that no more than 4 Pa of negative pressure is created 

inside the installation room with respect to the outside, otherwise provide for an additional air intake in the room.

Содержание ARCO 7 T1

Страница 1: ...INSTALLER MANUAL Pellet Stove EN new 2023CADELsrl Allrightsreserved Tuttiidirittiriservati ARCO 7T1 ARCO 7T1 BI FLUX ARCO 9T2 ARCO 9T2 BI FLUX ELLE PLUS 9T2 LUCE PLUS 9T2...

Страница 2: ...6 2 MINIMUM DISTANCES 11 6 3 OVERALL DIMENSIONS 12 6 4 REMOVAL ASSEMBLY OFTHE FRAME LUCE 13 6 5 REMOVAL ASSEMBLY OFTHE FRAME ELLE 13 6 6 REMOVAL ASSEMBLY OFTHE FRAME ARCO 14 6 7 STOVE DOOR REMOVAL IN...

Страница 3: ...cialized Stove repairer WARNING symbols indicates an important note 2 PACKAGING AND HANDLING 2 1 PACKAGING ThepackagingismadeupofrecyclablecardboardboxesaccordingtoRESYstandards recyclableexpandedpoly...

Страница 4: ...th the utmost care 3 CHIMNEY FLUE 3 1 PREPARING THE SMOKE EXPULSION SYSTEM The combustion product expulsion system is a particularly important element for the proper operation of the appliance and mus...

Страница 5: ...mt 10 mt Maximum length with 3 unions 4 5 mt 8 mt Maximum number of unions 3 3 Level section minimum inclination 3 4 mt 4 mt Installation at a height above 1200 m a s l NO Obligatory 3 4 FLUE CHIMNEY...

Страница 6: ...e internal section of the chimney prevent the penetration of rain or snow ensure the outlet of smoke even in the event of wind windproof chimneypot the height of outflow must be beyond the reflux area...

Страница 7: ...tion devices e g vmc electric fan for stale air extraction kitchen hood other stoves etc in the same room or in communicating rooms of the same housing unit could cause negative pressure in the room I...

Страница 8: ...mm 1 m 80 mm 3 m 1 m 100 mm 7 m 4 m Fig 7 Directairinflow Fig 8 Airinletforsealed chamberinstallation LEGEND Fig 7 Fig 8 1 Roomtoventilate 2 Externalairinlet 4 Shieldgrid 5 Curveinlettoturndownwards 4...

Страница 9: ...ses install suitable insulation between the flue and the ceiling Always check and comply with the plate data of the flue specifically the minimum safety distances from combustible materials The previo...

Страница 10: ...384 1 which is resistant to soot fire and which complies with the distances prescribed by the combustible materials indicated on the plate data there is a suitable combustion air flow to the appliance...

Страница 11: ...furniture curtains or sofas as a precaution increase the stove clearances substantially to avoid possible deterioration due to the effect of heat Fig 12 Safetydistancesfromcombustiblematerial LEGENDA...

Страница 12: ...hout emptying the system e g by using a double shut off gate or suitable flexible connection 1 The national reference standard for the installation of domestic appliances is UNI 10683 IT DTU NF 24 1 F...

Страница 13: ...s follows Remove the 4 screws at the bottom of the frame see Fig 17 Push the frame upwards and release the teeth Remove the frame see Fig 18 To assemble the frame proceed in reverse order Fig 17 Remov...

Страница 14: ...the frame proceed in reverse order Fig 21 Removethesecurityscrew Fig 22 Releasetheteeth Fig 23 Removetheframe 6 7 STOVE DOOR REMOVAL INSTALLATION DOOR REMOVAL For some operations e g side panel assemb...

Страница 15: ...screwdriver lift the lever so that the door is locked 6 8 HOT AIR DUCTING SYSTEM LUCE PLUS 9 The stove is provided with 1 hot air outlet and by default is oriented as follows front see Fig 26 Fig 26...

Страница 16: ...epipe Fig 31 Removethebox Fig 32 Removethebox Fig 33 Newpipe 6 9 ASSEMBLY OF UPPER EXHAUST WITH CONCENTRIC KIT The stove is designed to have the upper exhaust with concentric using a dedicated kit The...

Страница 17: ...ect it to the combustion air sleeve see Fig 38 Fig 37 Inserttheflexiblehose Fig 38 Connecttheflexiblehose The stove is ready to be connected to the flue with the concentric pipe 6 10 REAR OR UPPER FUM...

Страница 18: ...in hot air temperature Use pipes with smooth internal surface and a diameter of 80 mm Fit the pipe with insulating material if it passes through a cold wall The outlet must be protected by a grid with...

Страница 19: ...t be replaced by an authorized technician When the stove is not going to be used for a long period of time it advisable to remove the plug from the socket on the wall An electrical connection to a UPS...

Страница 20: ...tpipes fumeconduit chimneyflue chimneypot mustalwaysbecleaned scrubbedandcheckedbyanauthorized technicianincompliancewithlocalregulations withtheinstructionsofthemanufacturerandthoseofyourinsurancecom...

Страница 21: ...inspection cap see Fig 51 Clean with a pipe cleaner and suction any ash accumulated inside see Fig 52 and Fig 53 After cleaning repeat the operation in reverse making sure the gasket is intact and ef...

Страница 22: ...LEANING Every end of season or every 2000 hours of operation it is necessary to clean the fume passages Remove the door see the dedicated chapter Push the head of the firebox up tilt the piece and pul...

Страница 23: ...the fume extraction fan seeFig 61 After cleaning repeat the operation in reverse making sure the gasket is intact and efficient if necessary have it replaced by an authorised technician Fig 60 Remove...

Страница 24: ...flat cable Replace the flat cable Faulty electronic board Replace the mother board Pellets do not reach the combustion chamber Empty hopper Full the hopper Open fire door or open pellet door Close fir...

Страница 25: ...ly and the glass blackens Not sufficient com bustion air Check as following probable obstructions of the combustible air inlet from the back or from the bottom of the stove burning pot obstructed hole...

Страница 26: ...nt temperatu re reached The stove is at its minimum value Increase the desired ambient temperature Stove running and display showing Smoke Overtepe rature Reached fume outlet limit temperature The sto...

Страница 27: ...lows Remove the frame see the dedicated chapters After these operations you can have access at the following components geared motor ignition plug ambient fan fume fan ambient probe fume probe thermos...

Страница 28: ...Nm3 Medium POWDER CONTENTS at 13 O2 Min Max 14 14 mg Nm3 CHIMNEY DEPRESSION Max 9 11 Pa ON SHARED CHIMNEY FLUE NO FUME OUTLET DIAMETER 80 mm COMBUSTIBLE Pellet 6 7 mm PELLETS HEATINGVALUE 5 kWh kg PEL...

Страница 29: ...um POWDER CONTENTS at 13 O2 Min Max 15 15 mg Nm3 15 15 mg Nm3 15 15 mg Nm3 CHIMNEY DEPRESSION Max 10 11 Pa 10 11 Pa 10 11 Pa ON SHARED CHIMNEY FLUE NO NO NO FUME OUTLET DIAMETER 80 mm 80 mm 80 mm COMB...

Страница 30: ...NOTE...

Страница 31: ...NOTE...

Страница 32: ...www cadelsrl com www free point it www pegasoheating com CADEL srl 31025 S Lucia di Piave TV Via Martiri della Libert 74 Italy Tel 39 0438 1520200 Rev 00 2023...

Отзывы: