background image

11

LUCE -  ELLE - ARCO

A sealed installation does not consume the room’s oxygen because it draws all the air from the outer environment (if suitably 

ducted) and makes it possible to install the product in all houses that require a high degree of insulation such as “passive” or “high 

energy efficiency” houses. Thanks to this technology there is no risk of smoke emissions in the room and no air inlets - hence not 

even the relevant ventilation grilles - are required in the installation premises.

Consequently, there will be more draughts of cold air in the room, thus making it more comfortable and increasing the overall 

efficiency of the system. The sealed stove in a sealed installation is compatible with the presence of forced ventilation or premises 

that might have negative pressure with respect to the outside.

6.2 

MINIMUM DISTANCES

Observe the distances from flammable objects (sofas, furniture, wood panelling, etc..) as specified in the following diagram. 

If objects considered to be particularly sensitive to heat are present, such as furniture, curtains or sofas, as a precaution, increase 

the stove clearances substantially to avoid possible deterioration due to the effect of heat.

Fig. 12 - Safety distances from combustible material.

.LEGENDA

Fig. 12

dR (rear distance)

200 mm

dS (side distance)

200 mm

dB (lower distance)

15 mm

dC (upper distance)

750 mm

dP (front radiation)

1000 mm

dF (floor radiation)

1000 mm

dL (side radiation)

1000 mm

1

FLOOR

2

FRONT FLAMMABLE MATERIAL

3

AREA SUBJECT TO RADIATION

4

FLOOR GUARD

5

RADIATED SURFACE TO BE PROTECTED

6

REAR/SIDE/UPPER FLAMMABLE SURFACE

If the floor is made of combustible material, use a protection made of non-combustible material (steel, glass...) that also protects 

the front from any falling combusted material during cleaning operations.

Always fit a floor guard if the floor is made of flammable material.

Install the stove also detached from any non-combustible walls/surfaces, observing a minimum clearance of 

200mm 

(back) and 

200mm 

(side) to allow effective aeration of the appliance and a good distribution of heat in the room.

In any case, ensure adequate distance to facilitate access during cleaning and extraordinary maintenance. If this is not possible, it 

must still be possible to distance the product from adjacent walls/elements.

Содержание ARCO 7 T1

Страница 1: ...INSTALLER MANUAL Pellet Stove EN new 2023CADELsrl Allrightsreserved Tuttiidirittiriservati ARCO 7T1 ARCO 7T1 BI FLUX ARCO 9T2 ARCO 9T2 BI FLUX ELLE PLUS 9T2 LUCE PLUS 9T2...

Страница 2: ...6 2 MINIMUM DISTANCES 11 6 3 OVERALL DIMENSIONS 12 6 4 REMOVAL ASSEMBLY OFTHE FRAME LUCE 13 6 5 REMOVAL ASSEMBLY OFTHE FRAME ELLE 13 6 6 REMOVAL ASSEMBLY OFTHE FRAME ARCO 14 6 7 STOVE DOOR REMOVAL IN...

Страница 3: ...cialized Stove repairer WARNING symbols indicates an important note 2 PACKAGING AND HANDLING 2 1 PACKAGING ThepackagingismadeupofrecyclablecardboardboxesaccordingtoRESYstandards recyclableexpandedpoly...

Страница 4: ...th the utmost care 3 CHIMNEY FLUE 3 1 PREPARING THE SMOKE EXPULSION SYSTEM The combustion product expulsion system is a particularly important element for the proper operation of the appliance and mus...

Страница 5: ...mt 10 mt Maximum length with 3 unions 4 5 mt 8 mt Maximum number of unions 3 3 Level section minimum inclination 3 4 mt 4 mt Installation at a height above 1200 m a s l NO Obligatory 3 4 FLUE CHIMNEY...

Страница 6: ...e internal section of the chimney prevent the penetration of rain or snow ensure the outlet of smoke even in the event of wind windproof chimneypot the height of outflow must be beyond the reflux area...

Страница 7: ...tion devices e g vmc electric fan for stale air extraction kitchen hood other stoves etc in the same room or in communicating rooms of the same housing unit could cause negative pressure in the room I...

Страница 8: ...mm 1 m 80 mm 3 m 1 m 100 mm 7 m 4 m Fig 7 Directairinflow Fig 8 Airinletforsealed chamberinstallation LEGEND Fig 7 Fig 8 1 Roomtoventilate 2 Externalairinlet 4 Shieldgrid 5 Curveinlettoturndownwards 4...

Страница 9: ...ses install suitable insulation between the flue and the ceiling Always check and comply with the plate data of the flue specifically the minimum safety distances from combustible materials The previo...

Страница 10: ...384 1 which is resistant to soot fire and which complies with the distances prescribed by the combustible materials indicated on the plate data there is a suitable combustion air flow to the appliance...

Страница 11: ...furniture curtains or sofas as a precaution increase the stove clearances substantially to avoid possible deterioration due to the effect of heat Fig 12 Safetydistancesfromcombustiblematerial LEGENDA...

Страница 12: ...hout emptying the system e g by using a double shut off gate or suitable flexible connection 1 The national reference standard for the installation of domestic appliances is UNI 10683 IT DTU NF 24 1 F...

Страница 13: ...s follows Remove the 4 screws at the bottom of the frame see Fig 17 Push the frame upwards and release the teeth Remove the frame see Fig 18 To assemble the frame proceed in reverse order Fig 17 Remov...

Страница 14: ...the frame proceed in reverse order Fig 21 Removethesecurityscrew Fig 22 Releasetheteeth Fig 23 Removetheframe 6 7 STOVE DOOR REMOVAL INSTALLATION DOOR REMOVAL For some operations e g side panel assemb...

Страница 15: ...screwdriver lift the lever so that the door is locked 6 8 HOT AIR DUCTING SYSTEM LUCE PLUS 9 The stove is provided with 1 hot air outlet and by default is oriented as follows front see Fig 26 Fig 26...

Страница 16: ...epipe Fig 31 Removethebox Fig 32 Removethebox Fig 33 Newpipe 6 9 ASSEMBLY OF UPPER EXHAUST WITH CONCENTRIC KIT The stove is designed to have the upper exhaust with concentric using a dedicated kit The...

Страница 17: ...ect it to the combustion air sleeve see Fig 38 Fig 37 Inserttheflexiblehose Fig 38 Connecttheflexiblehose The stove is ready to be connected to the flue with the concentric pipe 6 10 REAR OR UPPER FUM...

Страница 18: ...in hot air temperature Use pipes with smooth internal surface and a diameter of 80 mm Fit the pipe with insulating material if it passes through a cold wall The outlet must be protected by a grid with...

Страница 19: ...t be replaced by an authorized technician When the stove is not going to be used for a long period of time it advisable to remove the plug from the socket on the wall An electrical connection to a UPS...

Страница 20: ...tpipes fumeconduit chimneyflue chimneypot mustalwaysbecleaned scrubbedandcheckedbyanauthorized technicianincompliancewithlocalregulations withtheinstructionsofthemanufacturerandthoseofyourinsurancecom...

Страница 21: ...inspection cap see Fig 51 Clean with a pipe cleaner and suction any ash accumulated inside see Fig 52 and Fig 53 After cleaning repeat the operation in reverse making sure the gasket is intact and ef...

Страница 22: ...LEANING Every end of season or every 2000 hours of operation it is necessary to clean the fume passages Remove the door see the dedicated chapter Push the head of the firebox up tilt the piece and pul...

Страница 23: ...the fume extraction fan seeFig 61 After cleaning repeat the operation in reverse making sure the gasket is intact and efficient if necessary have it replaced by an authorised technician Fig 60 Remove...

Страница 24: ...flat cable Replace the flat cable Faulty electronic board Replace the mother board Pellets do not reach the combustion chamber Empty hopper Full the hopper Open fire door or open pellet door Close fir...

Страница 25: ...ly and the glass blackens Not sufficient com bustion air Check as following probable obstructions of the combustible air inlet from the back or from the bottom of the stove burning pot obstructed hole...

Страница 26: ...nt temperatu re reached The stove is at its minimum value Increase the desired ambient temperature Stove running and display showing Smoke Overtepe rature Reached fume outlet limit temperature The sto...

Страница 27: ...lows Remove the frame see the dedicated chapters After these operations you can have access at the following components geared motor ignition plug ambient fan fume fan ambient probe fume probe thermos...

Страница 28: ...Nm3 Medium POWDER CONTENTS at 13 O2 Min Max 14 14 mg Nm3 CHIMNEY DEPRESSION Max 9 11 Pa ON SHARED CHIMNEY FLUE NO FUME OUTLET DIAMETER 80 mm COMBUSTIBLE Pellet 6 7 mm PELLETS HEATINGVALUE 5 kWh kg PEL...

Страница 29: ...um POWDER CONTENTS at 13 O2 Min Max 15 15 mg Nm3 15 15 mg Nm3 15 15 mg Nm3 CHIMNEY DEPRESSION Max 10 11 Pa 10 11 Pa 10 11 Pa ON SHARED CHIMNEY FLUE NO NO NO FUME OUTLET DIAMETER 80 mm 80 mm 80 mm COMB...

Страница 30: ...NOTE...

Страница 31: ...NOTE...

Страница 32: ...www cadelsrl com www free point it www pegasoheating com CADEL srl 31025 S Lucia di Piave TV Via Martiri della Libert 74 Italy Tel 39 0438 1520200 Rev 00 2023...

Отзывы: