Page 14
509 Sharptown Road P.O. Box 345 Bridgeport, NJ 08014
Email: [email protected] Fax: 856-467-5511
Internet: http://caddycorp.com Phone: 856-467-4222
5.
Once pressure is set, the detergent injector may be operated by following these steps:
Detergent Injector
a.
Fill detergent container located behind access door.
b.
Drop tubing from injector into container.
c.
Cover containers by slipping metal disc over opening.
d.
Locate water bypass screw and find metering adjusting screw.
e.
To activate injector, turn the bypass screw clockwise until fluid begins to be drawn up from the
container.
f.
After fluid reaches the injector, the feed rate may be adjusted by turning the bypass screw.
Clockwise for more fluid and counter clockwise for less fluid.
6.
Servicing Detergent Injector
a.
The check valve parts (which are in the metering knob), can be cleaned by removing the four
screws.
b.
If the ventilator spray nozzles become clogged or restricted the injector may not operate. If it is
temporarily inconvenient to remove the restriction, the injector may be put back into operation by
turning the water bypass screw clockwise. Once the restriction is removed, reset bypass screw.