background image

 

 

 

 

 

30 

LOCATION 

PAGE 

DESCRIPTION 

DATA 

DEFAULT 

174 

20 

Program Zones 3 Thru 6 For Normally Closed Operation 

 

"0" Supervised 

175 

21 

Program Zones 1 & 2 For Normally Closed Operation 

 

"0" Supervised 

176 

21 

Split Report - Tamper, Download Complete,  & Autotest 

 

"0" Phone #1 

177 

22 

Split Report - AC Failure, Low Bat, Open/Close, & Maintenance Open/Close 

 

"0" Phone #1 

178 

22 

Secondary Entry Delay Time 

 

"0" 

179 

22 

Secondary Exit Delay Time 

 

"0" 

180 

22 

Loop Response Time 

 

"0" 500 MS 

181 

22 

Hourly Autotest / Auto-Set Clock 

 

"0" 

182 

23 Format 

Over-Ride 

 

"0" 

183 

23 Format 

Over-Ride 

 

"0" 

184-185 

23 Reserved 

Locations 186 - 191 

 Reserved 

186 

23 

Zone 1 Special Characteristics 

Value Description 

 "14" 

187 

23 

Zone 2 Special Characteristics 

 

"14" 

188 

23 

Zone 3 Special Characteristics 

 

"14" 

189 

23 

Zone 4 Special Characteristics 

 

"14" 

190 

23 

Zone 5 Special Characteristics 




Fast Loop Response 
Bypass Capability 
Zone Restoral Reporting 
Chime Enable 

 "14" 

191 

23 

Zone 6 Special Characteristics 

 

"14" 

192-193 

23 Reserved 

 Reserved 

194 

23 

Telephone Line Fault Monitor 

 

"0" Disabled 

195 

23 

Telephone Line Fault, Delay Of Activation 

 

"3" 30 Seconds 

196 

23 

Answering Machine Defeat Enable 

 

"0" Disabled 

197 

24 

Force Arming Enable 

 

"0" Disabled 

198 

24 

Time For Automatic Arming,  Hour - Tens Digit 

 

"2" 

199 

24 

Time For Automatic Arming,  Hour - Ones Digit 

 

"0" 

200 

24 

Time For Automatic Arming,  Minute - Tens Digit 

 

"0" 

201 

24 

Time For Automatic Arming,  Minute - Ones Digit 

 

"0" 

202 

24 

Automatic Arming Enable 

 

"0" 

203 

24 

Dynamic Battery Test 

 

"0" 

204 

24 

Dual Report - Tamper, Download Complete, & Autotest 

 

"0" Phone #1 

205 

24 

Dual Report - Ac Failure, Low Bat, Open/Close, Maintenance Open/Close 

 

"0" Phone #1 

206 

25 

Dual Report Everything 

 

"0" 

207 

25 

Callback Phone Number Control 

 

"0" 

208 

25 Format 

Over-Ride 

 

"0" 

209 

25 Format 

Over-Ride 

 

"0" 

210 

26 

Exit Error Communicator Code 

 

"0" 

211 

26 

Recent Closing Communicator Code 

 

"0" 

212-215 

26 

User #8 Arm / Disarm Code 

 

 

 

 

"15" Disabled 

216-219 

26 

User #9 Arm / Disarm Code 

 

 

 

 

"15" Disabled 

220-223 

26 

User #10 Arm / Disarm Code 

 

 

 

 

"15" Disabled 

224-227 

26 

User #11 Arm / Disarm Code 

 

 

 

 

"15" Disabled 

228-231 

26 

User #12 Arm / Disarm Code 

 

 

 

 

"15" Disabled 

232-235 

26 

User #13 Arm / Disarm Code 

 

 

 

 

"15" Disabled 

236-239 

26 

User #14 Arm / Disarm Code 

 

 

 

 

"15" Disabled 

240 

26 

Number Of Dial Attempts To Phone #2 

 

"0" 

241 

26 

Listen-In Time 

 

“0" 

242 

26 Reserved 

 Reserved 

243 

26 Entry/Keypad 

Sounder 

 

“0" 

244 

26 

Zone #1 Special Characteristics 

Locations 244 - 249

 

 "8" 

245 

26 

Zone #2 Special Characteristics 

Value Description 

 "8" 

246 

26 

Zone #3 Special Characteristics 

 

"8" 

247 

26 

Zone #4 Special Characteristics 

 

"8" 

248 

26 

Zone #5 Special Characteristics 

 

"8' 

249 

26 

Zone #6 Special Characteristics 




Cross Zone 
Entry Guard 
Group Bypass 
Trouble Reporting 

 "8" 

Содержание Ranger 8600E

Страница 1: ...o Program the Ranger 8600E 7 Keypad Programming Examples 8 Programming Phone Numbers Formats 9 Communicator Format Selection Guide 10 Optional Programming Instructions 10 27 Download Programming Instr...

Страница 2: ...r 8600E functions After installation of the security system complete the information on page 1 of the users manual and explain the system operation to all security system owners operators Standard Par...

Страница 3: ...e programmed for dual and or split reporting DYNAMIC BATTERY TEST When enabled in location 203 the 8600E can be programmed to perform a dynamic battery test for a selected duration at 6 00 AM ENTRY GU...

Страница 4: ...iration program a 4 For a bell test at closing kissoff program an 8 The 8600E allows downloading of custom information to 9050 LCD keypads The 8600E has a Fire Alarm Verification feature which can be...

Страница 5: ...5 Terminal Drawing Special Notes...

Страница 6: ...d be 15 watt at 8 or 16 ohm or 30 40 watt at 4 8 or 16 ohms If siren driver disable is selected in location 132 output becomes voltage output 12VDC 1 Amp maximum load 16 17 Smoke detector power 12VDC...

Страница 7: ...9 you would determine that the data in location 000 is 9 2 If the data in location 000 is 6 the LED for zone 2 2 and zone 3 4 would be added 2 4 6 indicating the data in that location to be 6 3 If no...

Страница 8: ...8...

Страница 9: ...s a local only control LOCATION 053 DISABLING THE SECONDARY TELEPHONE NUMBER AS A BACKUP Location 053 is used to disable the secondary phone number as a backup This feature can be used with split repo...

Страница 10: ...G THE MASTER ARM DISARM CODE Locations 000 003 contain master arm disarm code user number 1 Location 000 contains the first digit of the code location 003 contains the fourth digit of the code THE COD...

Страница 11: ...ime of 12 minutes NOTE This location shall be programmed for a minimum of 4 minutes on UL Listed systems LOCATIONS 078 083 PROGRAMMING THE ZONE TYPES Locations 078 through 083 contain a number identif...

Страница 12: ...keys are pressed simultaneously on the keypad The desired Keypad panic code is programmed in locations 092 093 If both locations are 0 the Keypad panic double keypress is disabled Location 092 contai...

Страница 13: ...h time zone 1 creates an alarm Location 104 contains the standard digit and location 105 contains the extended digit When using 4 2 format the number programmed in location 104 is sent as the ones dig...

Страница 14: ...format is selected the restorals will be reported by zone If a restoral code is programmed and an extended format is not selected a restoral code will be sent when all of the previously reported cond...

Страница 15: ...15...

Страница 16: ...for the appropriate phone number s before ending the notification process If this location contains an 8 the communicator will make eight attempts to the first number and then eight attempts to a seco...

Страница 17: ...sarm code VALUE DESCRIPTION 1 Activation by pressing 1 and 7 keys simultaneously 2 Momentary activation at arming 4 Momentary at end of exit delay 8 Momentary at kiss off ringback LOCATION 143 SMOKE P...

Страница 18: ...ollowing chart and program the sum in this location For example to reverse outputs 2 and 3 program a 6 2 4 6 in location 149 VALUE DESCRIPTION 1 Invert auxiliary 1 output 2 Invert auxiliary 2 output 4...

Страница 19: ...the 24 hour time is 17 25 so this location should contain a 1 which is the current hour tens digit If the current time is 9 36 AM the 24 hour time is 09 36 so this location should contain a 0 LOCATION...

Страница 20: ...s 086 087 NOTE FOR U L GRADE A INSTALLATIONS THIS FEATURE SHALL BE DISABLED LOCATION 168 171 PROGRAMMING THE SEED CODE FOR ROTATING MAINTENANCE CODES Locations 168 171 contain the complex or seed code...

Страница 21: ...G PROGRAMMING TAMPER DOWNLOAD COMPLETE AND AUTOTEST TO REPORT TO THE SECONDARY PHONE NUMBER The 8600E is capable of sending certain reports to the secondary telephone number This feature known as spli...

Страница 22: ...r of 10 second increments in the secondary entry delay This delay can be programmed from 10 to 150 seconds 1 10 sec thru 15 150 sec NOTE ACCORDING TO SEC 26 OF U L 1023 THE SECONDARY ENTRY TIME SHALL...

Страница 23: ...keypad sounder and a 3 will activate both any time a phone line fault is detected A 9 will activate the siren a 10 will activate the keypad sounder and an 11 will activate both if a line fault is det...

Страница 24: ...tery testing during each 24 hour period The red Power LED will flash if the battery fails the dynamic test Factory default is 0 disabled NOTE The clock must be set locations 153 161 for dynamic batter...

Страница 25: ...ocation 207 controls the use of the callback telephone number The callback number must be programmed in the download section for this location to have an effect The callback number will be used accord...

Страница 26: ...34 will be used LOCATION 241 LISTEN IN TIME Location 241 is used to program Listen In time in 30 second increments Valid entries are 1 3 1 30 3 90 LOCATION 242 RESERVED LOCATION 243 ENTRY KEYPAD SOUND...

Страница 27: ...ted in the instructions provided with the CADDX download software package LOCATIONS 264 279 CALL BACK TELEPHONE NUMBER The presence of a phone number in locations 264 279 will cause the control panel...

Страница 28: ...Time Out 2 Minute Increments 4 8 Minutes 078 11 Zone 1 Type 3 Entry Exit 079 11 Zone 2 Type Locations 078 083 5 Int Follower 080 11 Zone 3 Type DATA TYPE DATA TYPE 6 Instant 081 11 Zone 4 Type 1 Day Z...

Страница 29: ...utput 2 1 Fire Alarm 147 17 Auxiliary Output 3 2 Panic Duress 148 17 Auxiliary Output 4 3 Armed State 149 18 Inverting The Auxiliary Outputs 0 High Going Low 150 18 Delay Ac Power Loss Report 3 6 Minu...

Страница 30: ...ng Hour Tens Digit 2 199 24 Time For Automatic Arming Hour Ones Digit 0 200 24 Time For Automatic Arming Minute Tens Digit 0 201 24 Time For Automatic Arming Minute Ones Digit 0 202 24 Automatic Armin...

Страница 31: ...ith the National Electrical Code ANSI and NFPA standards When the built in digital communicator is utilized in conjunction with a U L installation it must report at a minimum a burglary zone a fire zo...

Страница 32: ...ent Code SIA Code Description 1 FA Fire Alarm 2 PA Panic alarm 3 BA Burglary Alarm 4 GA Gas Alarm 5 KA Heat Alarm 6 WA Water Alarm 7 QA Emergency Alarm 8 SA Sprinkler Alarm 9 UA Untyped Alarm 10 HA Ho...

Страница 33: ...ption 0 122 Silent Panic for Loc 93 only 1 110 Fire Alarm 2 120 Panic alarm 3 130 Burglary Alarm 4 131 Perimeter Alarm 5 132 Interior Alarm 6 133 24 hour Burglary 7 134 Entry Alarm 8 135 Day Night Ala...

Страница 34: ...rect the situation The customer also has the right to bring a complaint to the FCC if he feels the disconnection is not warranted CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone com...

Страница 35: ...G IF ANY DEFECT APPEARS DURING THE WARRANTY PERIOD RETURN IT TO CADDX POSTAGE PREPAID THE UNIT WILL BE REPAIRED AND RETURNED FOR THE REMAINING 36 MONTHS OF WARRANTY THE UNIT WILL BE REPAIRED FOR A FEE...

Отзывы: