LOCATION 100-101: PROGRAMMING TO REPORT FAILURE TO COMMUNICATE 

The 8600E has the ability to communicate each time communication is re-established after a signal has been unable to 
report.  The data that failed to communicate will not be sent, but can be recovered from the log.  The desired "Failure To 
Communicate" code is programmed in locations 100-101. If both locations are "0", "Failure To Communicate" will not be 
reported.  Location 100 contains the standard digit, and location 101 contains the extended digit.  When using 4 + 2 
format, the number programmed in location 100 is sent as the "ones" digit. The "tens" digit is programmed in location 
101. 

 
LOCATION 102: PROGRAMMING TO REPORT CLOSINGS 

The Ranger 8600E has the ability to report a closing code each time the control is armed. The desired closing code is 
programmed in location 102. If this location contains a "0", closings will not be reported. When using 4+2 format, the 
number programmed in this location is sent as the "tens" digit. The "ones" digit is automatically the man number. When 
using the remote arming input, the man number is 1. When using a one button "Quick Arm" code the man number is 1. 
The closing report will not be initiated until the end of the exit delay.  When using Auto-Arm, the man number is 9. 

 
LOCATION 103: PROGRAMMING TO REPORT OPENINGS 

The Ranger 8600E has the ability to report an opening code each time the control is disarmed. The desired opening 
code is programmed in location 103. If this location contains a "0", openings will not be reported. When using 4+2 
format, the number programmed in this location is sent as the "tens" digit. The "ones" digit is automatically the man 
number. When using the remote arming input, the man number is 1. 
 

NOTE TO COMMUNICATOR CODES: If the extended digit is “0” the event will be reported based on the zone type. 

Pulse Formats: FIRE=1, PANIC=2, BURG = 3

 
LOCATION 104-105: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 1
 

Locations 104-105 contain the communicator code to be reported each time zone 1 creates an alarm. Location 104 
contains the standard digit, and location 105 contains the extended digit. When using 4+2 format, the number 
programmed in location 104 is sent as the "ones" digit. The "tens" digit is programmed in location 105. 

 

 

LOCATION 106-107: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 2  

Locations 106-107 contain the communicator code to be reported each time zone 2 creates an alarm. Location 106 
contains the standard digit, and location 107 contains the extended digit. When using 4+2 format, the number 
programmed in location 106 is sent as the "ones" digit. The "tens" digit is programmed in location 107. 

 
 LOCATION 108-109: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 3 

Locations 108-109 contain the communicator code to be reported each time zone 3 creates an alarm. Location 108 
contains the standard digit, and location 109 contains the extended digit. When using 4+2 format, the number 
programmed in location 108 is sent as the "ones" digit. The "tens" digit is programmed in location 109. 

 
LOCATION 110-111: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 4  

Locations 110-111 contain the communicator code to be reported each time zone 4 creates an alarm. Location 110 
contains the standard digit, and location 111 contains the extended digit. When using 4+2 format, the number 
programmed in location 110 is sent as the "ones" digit. The "tens" digit is programmed in location 111. 

 
LOCATION 112-113: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 5  

Locations 112-113 contain the communicator code to be reported each time zone 5 creates an alarm. Location 112 
contains the standard digit, and location 113 contains the extended digit. When using 4+2 format, the number 
programmed in location 112 is sent as the "ones" digit. The "tens" digit is programmed in location 113. 

 
LOCATION 114-115: PROGRAMMING THE COMMUNICATOR CODE FOR ZONE 6 

Locations 114-115 contain the communicator code to be reported each time zone 6 creates an alarm. Location 114 
contains the standard digit, and location 115 contains the extended digit. When using 4+2 format, the number 
programmed in location 114 is sent as the "ones" digit. The "tens" digit is programmed in location 115. 

 
LOCATION 116-119: RESERVED 
 

Содержание Ranger 8600E

Страница 1: ...o Program the Ranger 8600E 7 Keypad Programming Examples 8 Programming Phone Numbers Formats 9 Communicator Format Selection Guide 10 Optional Programming Instructions 10 27 Download Programming Instr...

Страница 2: ...r 8600E functions After installation of the security system complete the information on page 1 of the users manual and explain the system operation to all security system owners operators Standard Par...

Страница 3: ...e programmed for dual and or split reporting DYNAMIC BATTERY TEST When enabled in location 203 the 8600E can be programmed to perform a dynamic battery test for a selected duration at 6 00 AM ENTRY GU...

Страница 4: ...iration program a 4 For a bell test at closing kissoff program an 8 The 8600E allows downloading of custom information to 9050 LCD keypads The 8600E has a Fire Alarm Verification feature which can be...

Страница 5: ...5 Terminal Drawing Special Notes...

Страница 6: ...d be 15 watt at 8 or 16 ohm or 30 40 watt at 4 8 or 16 ohms If siren driver disable is selected in location 132 output becomes voltage output 12VDC 1 Amp maximum load 16 17 Smoke detector power 12VDC...

Страница 7: ...9 you would determine that the data in location 000 is 9 2 If the data in location 000 is 6 the LED for zone 2 2 and zone 3 4 would be added 2 4 6 indicating the data in that location to be 6 3 If no...

Страница 8: ...8...

Страница 9: ...s a local only control LOCATION 053 DISABLING THE SECONDARY TELEPHONE NUMBER AS A BACKUP Location 053 is used to disable the secondary phone number as a backup This feature can be used with split repo...

Страница 10: ...G THE MASTER ARM DISARM CODE Locations 000 003 contain master arm disarm code user number 1 Location 000 contains the first digit of the code location 003 contains the fourth digit of the code THE COD...

Страница 11: ...ime of 12 minutes NOTE This location shall be programmed for a minimum of 4 minutes on UL Listed systems LOCATIONS 078 083 PROGRAMMING THE ZONE TYPES Locations 078 through 083 contain a number identif...

Страница 12: ...keys are pressed simultaneously on the keypad The desired Keypad panic code is programmed in locations 092 093 If both locations are 0 the Keypad panic double keypress is disabled Location 092 contai...

Страница 13: ...h time zone 1 creates an alarm Location 104 contains the standard digit and location 105 contains the extended digit When using 4 2 format the number programmed in location 104 is sent as the ones dig...

Страница 14: ...format is selected the restorals will be reported by zone If a restoral code is programmed and an extended format is not selected a restoral code will be sent when all of the previously reported cond...

Страница 15: ...15...

Страница 16: ...for the appropriate phone number s before ending the notification process If this location contains an 8 the communicator will make eight attempts to the first number and then eight attempts to a seco...

Страница 17: ...sarm code VALUE DESCRIPTION 1 Activation by pressing 1 and 7 keys simultaneously 2 Momentary activation at arming 4 Momentary at end of exit delay 8 Momentary at kiss off ringback LOCATION 143 SMOKE P...

Страница 18: ...ollowing chart and program the sum in this location For example to reverse outputs 2 and 3 program a 6 2 4 6 in location 149 VALUE DESCRIPTION 1 Invert auxiliary 1 output 2 Invert auxiliary 2 output 4...

Страница 19: ...the 24 hour time is 17 25 so this location should contain a 1 which is the current hour tens digit If the current time is 9 36 AM the 24 hour time is 09 36 so this location should contain a 0 LOCATION...

Страница 20: ...s 086 087 NOTE FOR U L GRADE A INSTALLATIONS THIS FEATURE SHALL BE DISABLED LOCATION 168 171 PROGRAMMING THE SEED CODE FOR ROTATING MAINTENANCE CODES Locations 168 171 contain the complex or seed code...

Страница 21: ...G PROGRAMMING TAMPER DOWNLOAD COMPLETE AND AUTOTEST TO REPORT TO THE SECONDARY PHONE NUMBER The 8600E is capable of sending certain reports to the secondary telephone number This feature known as spli...

Страница 22: ...r of 10 second increments in the secondary entry delay This delay can be programmed from 10 to 150 seconds 1 10 sec thru 15 150 sec NOTE ACCORDING TO SEC 26 OF U L 1023 THE SECONDARY ENTRY TIME SHALL...

Страница 23: ...keypad sounder and a 3 will activate both any time a phone line fault is detected A 9 will activate the siren a 10 will activate the keypad sounder and an 11 will activate both if a line fault is det...

Страница 24: ...tery testing during each 24 hour period The red Power LED will flash if the battery fails the dynamic test Factory default is 0 disabled NOTE The clock must be set locations 153 161 for dynamic batter...

Страница 25: ...ocation 207 controls the use of the callback telephone number The callback number must be programmed in the download section for this location to have an effect The callback number will be used accord...

Страница 26: ...34 will be used LOCATION 241 LISTEN IN TIME Location 241 is used to program Listen In time in 30 second increments Valid entries are 1 3 1 30 3 90 LOCATION 242 RESERVED LOCATION 243 ENTRY KEYPAD SOUND...

Страница 27: ...ted in the instructions provided with the CADDX download software package LOCATIONS 264 279 CALL BACK TELEPHONE NUMBER The presence of a phone number in locations 264 279 will cause the control panel...

Страница 28: ...Time Out 2 Minute Increments 4 8 Minutes 078 11 Zone 1 Type 3 Entry Exit 079 11 Zone 2 Type Locations 078 083 5 Int Follower 080 11 Zone 3 Type DATA TYPE DATA TYPE 6 Instant 081 11 Zone 4 Type 1 Day Z...

Страница 29: ...utput 2 1 Fire Alarm 147 17 Auxiliary Output 3 2 Panic Duress 148 17 Auxiliary Output 4 3 Armed State 149 18 Inverting The Auxiliary Outputs 0 High Going Low 150 18 Delay Ac Power Loss Report 3 6 Minu...

Страница 30: ...ng Hour Tens Digit 2 199 24 Time For Automatic Arming Hour Ones Digit 0 200 24 Time For Automatic Arming Minute Tens Digit 0 201 24 Time For Automatic Arming Minute Ones Digit 0 202 24 Automatic Armin...

Страница 31: ...ith the National Electrical Code ANSI and NFPA standards When the built in digital communicator is utilized in conjunction with a U L installation it must report at a minimum a burglary zone a fire zo...

Страница 32: ...ent Code SIA Code Description 1 FA Fire Alarm 2 PA Panic alarm 3 BA Burglary Alarm 4 GA Gas Alarm 5 KA Heat Alarm 6 WA Water Alarm 7 QA Emergency Alarm 8 SA Sprinkler Alarm 9 UA Untyped Alarm 10 HA Ho...

Страница 33: ...ption 0 122 Silent Panic for Loc 93 only 1 110 Fire Alarm 2 120 Panic alarm 3 130 Burglary Alarm 4 131 Perimeter Alarm 5 132 Interior Alarm 6 133 24 hour Burglary 7 134 Entry Alarm 8 135 Day Night Ala...

Страница 34: ...rect the situation The customer also has the right to bring a complaint to the FCC if he feels the disconnection is not warranted CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The telephone com...

Страница 35: ...G IF ANY DEFECT APPEARS DURING THE WARRANTY PERIOD RETURN IT TO CADDX POSTAGE PREPAID THE UNIT WILL BE REPAIRED AND RETURNED FOR THE REMAINING 36 MONTHS OF WARRANTY THE UNIT WILL BE REPAIRED FOR A FEE...

Отзывы: