4) Enter a partition number.  Note: The default
allows access to 

all partitions. The first

keypress will remove access to the partition.
To reestablish access, press the partition
number again.  When completed, press [

U

].

The LCD Screen will prompt you for the next user code. 

5) If another user code needs to be programmed, return to Step 3.

6) To exit this feature, press [#]. 

NOTE: Any master arm/disarm code can add or change a user code if the master code has access to the
same partitions as the code being added/changed.  Consequently, when programming the user codes for a
partitioned system, leave at least one code access to all partitions or you will not be able to add new users
(can be "go to program code" if enabled in location 43 of the control panel).   Should you desire the end user
to be able to add new codes, you must remove the partition authority from all blank codes.

[

U

]-[9]-[8] 

Pressing [

U

]-[9]-[8] while the system is disarmed will cause the control to do a callback for a

download. NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [

U

]-[9]-[8] IF ENABLED IN

LOCATION 41 OF THE CONTROL PANEL.  (Refer to the NX-4, -6, -8 Installation Manual)

[

U

]-[9]-[9] Pressing 

[

U

]-[9]-[9] while the system is disarmed  will cause the control to seize the phone line for a

download. NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [

U

]-[9]-[9] IF ENABLED IN

LOCATION 41 OF THE CONTROL PANEL.  (Refer to the NX-4, -6, -8 Installation Manual)

[

U

]-[CHIME]

If enabled in the control panel, entering [

U

]-[CHIME] followed by a user code will allow a walk-through

zone test where all zones become silent and local (non-reporting).  Each time a zone is faulted, the
number of the faulted zone(s) will be displayed on the keypad and the chime will sound.  It will also
be entered into alarm memory and the internal log.  To exit at any time during this mode, enter a user
code.  Otherwise, the “Walk-Test Mode” will automatically exit after 15 minutes.

PARTITIONED SYSTEMS OPERATION

The NX-148 can be programmed to operate all the system partitions simultaneously.  To set the multi-partition mode,
use the [

U

]-[9]-[3] function, and answer "YES" to the question "Master keypad?".

NOTE: [

U

]-[1] followed by a code will 

temporarily access the Master Mode.  The keypad will revert back to its

assigned partition 60 seconds after a keypress or 10 seconds without a keypress. Press [#] to exit this mode.

LIGHTS IN PARTITIONING MASTER MODE

ARMED will illuminate if ALL partitions are armed.

READY will illuminate if ALL partitions are "Ready".  The 

ready light will flash if all areas are Ready or Force

armable.

FIRE will illuminate if ANY one area has a Fire condition.  The 

fire light will flash if ANY area has a Fire Trouble

condition.

POWER will illuminate if the primary power is connected to the NX-8 control panel.  It will flash if the system
has a low standby battery condition.

STAY will illuminate if ANY area has the 

stay light on.

CHIME will illuminate if ANY partition is in the "Chime" mode.

EXIT will illuminate if ANY area is timing an exit delay.  It will flash if ANY area is in the last 10 seconds of an
exit delay.

BYPASS will illuminate if ANY area has a zone bypassed.

CANCEL will flash during an abort delay time.  If a code is entered followed by the [CANCEL] key while this
light is flashing, all abortable reports will stop the communication process to the central station.  If a code is
entered followed by the [CANCEL] key during or after an alarm report, the 

cancel light will illuminate and

remain constant  until the central station has received the cancel report.

SOUNDER will sound if ANY area has the sounder on.  This includes Entry delay, Exit delay, Chime, and
Alarm.

Содержание NX-148

Страница 1: ... View 3 Programming Custom Messages 4 Set Keypad Options 4 Set Keypad Number Partition 5 Keypad Functions 5 7 Reading the Event Log 5 Set Elapsed Increments 5 Set System Time Date 5 Adjust Keypad Tone 6 View Zone Status 6 View Alarm Memory 6 Change User Codes 6 Assigning Authority Level 6 Partitioned System Operation 7 9 Service Display 9 10 Maximum Wire Run 11 Specifications Warranty Back NX 148 ...

Страница 2: ...he left and the segment number on the right The data will be displayed on the bottom line with the numbers 1 8 in the first 8 characters If the number appears this binary switch is on If a minus sign appears where the number should be this switch is off Toggle numbers on or off using the corresponding number digit 1 to toggle 1 8 to toggle 8 When the numbers are in the desired state enter the U ke...

Страница 3: ...module connected to the data terminal This allows these modules to be supervised by the control panel NOTE All modules should be connected and set to unique addresses prior to enrolling modules To enroll the modules enter the Program Mode of the NetworX control panel When the Program Mode is exited the control will enroll the devices The enrolling process takes about 12 seconds during which time t...

Страница 4: ... different custom message you must enable Custom Message Lock under the U 9 3 function U 9 3 SET KEYPAD OPTIONS 1 Enter U 9 3 The LCD Screen will prompt for a code 2 Enter program code The LCD will now prompt you through the options listed on the following chart The current state of the option will be shown in the lower right corner of the display Press U to exit the current state unchanged Otherw...

Страница 5: ...l now show the most recent event 3 To view the events from most recent to the oldest press the down scroll key 4 To view the events from the oldest to the newest press the up scroll key The display contains the following information Event User or Zone ID Date Month Day Indicates partition and U indicates an event not reported ß Time shown in 24 hour format This screen shows an opening of Partition...

Страница 6: ... user being changed 1 Enter U 5 The LCD Screen will prompt for a code 2 Enter master code The LCD Screen will prompt for a user Number 3 Enter the 2 digit user number always 2 digits i e 03 for user 3 The LCD screen will prompt for a new code 4 Enter the new user code designated for that individual The sounder will beep 3 times if it rejects the code 5 If another user code needs to be programmed r...

Страница 7: ...be entered into alarm memory and the internal log To exit at any time during this mode enter a user code Otherwise the Walk Test Mode will automatically exit after 15 minutes PARTITIONED SYSTEMS OPERATION The NX 148 can be programmed to operate all the system partitions simultaneously To set the multi partition mode use the U 9 3 function and answer YES to the question Master keypad NOTE U 1 follo...

Страница 8: ...lank Area Not Used or Authorized Dash Dash Area Not Ready Flashing Dash Area Ready to Force Arm Dash Flashing Area Armed Instant Area Dash Area Disarmed Ready to Arm Dash Area Area is Armed To disarm all of the areas press the x up scroll key To arm all of the areas press the down scroll y key To toggle a single area between the armed and disarmed conditions press U Area number For example if Area...

Страница 9: ... partition is selected SERVICE DISPLAY The following message will be displayed periodically if the security system requires service If you see this display press U 2 One or more of the following fault messages will be displayed Use the scroll keys to browse through them To exit the service messages press A short circuit of a control s power supply has occurred Open circuit has occurred on the bell...

Страница 10: ... of trouble on the bell or siren circuit A zone is tampered Press U to identify the tampered zone A wireless device has a low battery Press U to identify the zone A wireless or multiplexed zone device is not reporting to the control Press U to identify the zone A zone is experiencing some form of trouble probably wiring Press U to identify the zone The following chart provides the device numbers t...

Страница 11: ... the end of the wire When connecting more than one keypad to the end of the wire a heavier gauge wire will be required WHEN CONNECTED TO NX 8 WHEN CONNECTED TO NX 320 Length in feet Wire Gauge Wire Gauge 250 24 22 500 20 18 1000 18 16 1500 16 14 2500 14 12 SYSTEM NOTES ...

Страница 12: ...E PREPAID THE UNIT WILL BE REPAIRED AND RETURNED AT NO CHARGE FOR THE REMAINING 36 MONTHS OF WARRANTY THE CHARGE TO REPAIR OR REPLACE THIS UNIT WILL NOT EXCEED 10 00 PLUS SHIPPING AND HANDLING CADDX ASSUMES NO LIABILITY FOR CONSEQUENTIAL OR INDIRECT DAMAGE AND ACCEPTS NO RESPONSIBILITY FOR REPAIRING DAMAGE TO THE PRODUCT CAUSED BY MISUSE CARELESS HANDLING OR WHERE REPAIRS HAVE BEEN MADE BY OTHERS ...

Отзывы: