7
4) Enter a partition number. Note: The default
allows access to
all partitions. The first
keypress will remove access to the partition.
To reestablish access, press the partition
number again. When completed, press [
U
].
The LCD Screen will prompt you for the next user code.
5) If another user code needs to be programmed, return to Step 3.
6) To exit this feature, press [#].
NOTE: Any master arm/disarm code can add or change a user code if the master code has access to the
same partitions as the code being added/changed. Consequently, when programming the user codes for a
partitioned system, leave at least one code access to all partitions or you will not be able to add new users
(can be "go to program code" if enabled in location 43 of the control panel). Should you desire the end user
to be able to add new codes, you must remove the partition authority from all blank codes.
[
U
]-[9]-[8]
Pressing [
U
]-[9]-[8] while the system is disarmed will cause the control to do a callback for a
download. NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [
U
]-[9]-[8] IF ENABLED IN
LOCATION 41 OF THE CONTROL PANEL. (Refer to the NX-4, -6, -8 Installation Manual)
[
U
]-[9]-[9] Pressing
[
U
]-[9]-[9] while the system is disarmed will cause the control to seize the phone line for a
download. NOTE: A VALID USER CODE MAY BE REQUIRED AFTER [
U
]-[9]-[9] IF ENABLED IN
LOCATION 41 OF THE CONTROL PANEL. (Refer to the NX-4, -6, -8 Installation Manual)
[
U
]-[CHIME]
If enabled in the control panel, entering [
U
]-[CHIME] followed by a user code will allow a walk-through
zone test where all zones become silent and local (non-reporting). Each time a zone is faulted, the
number of the faulted zone(s) will be displayed on the keypad and the chime will sound. It will also
be entered into alarm memory and the internal log. To exit at any time during this mode, enter a user
code. Otherwise, the “Walk-Test Mode” will automatically exit after 15 minutes.
PARTITIONED SYSTEMS OPERATION
The NX-148 can be programmed to operate all the system partitions simultaneously. To set the multi-partition mode,
use the [
U
]-[9]-[3] function, and answer "YES" to the question "Master keypad?".
NOTE: [
U
]-[1] followed by a code will
temporarily access the Master Mode. The keypad will revert back to its
assigned partition 60 seconds after a keypress or 10 seconds without a keypress. Press [#] to exit this mode.
LIGHTS IN PARTITIONING MASTER MODE
ARMED will illuminate if ALL partitions are armed.
READY will illuminate if ALL partitions are "Ready". The
ready light will flash if all areas are Ready or Force
armable.
FIRE will illuminate if ANY one area has a Fire condition. The
fire light will flash if ANY area has a Fire Trouble
condition.
POWER will illuminate if the primary power is connected to the NX-8 control panel. It will flash if the system
has a low standby battery condition.
STAY will illuminate if ANY area has the
stay light on.
CHIME will illuminate if ANY partition is in the "Chime" mode.
EXIT will illuminate if ANY area is timing an exit delay. It will flash if ANY area is in the last 10 seconds of an
exit delay.
BYPASS will illuminate if ANY area has a zone bypassed.
CANCEL will flash during an abort delay time. If a code is entered followed by the [CANCEL] key while this
light is flashing, all abortable reports will stop the communication process to the central station. If a code is
entered followed by the [CANCEL] key during or after an alarm report, the
cancel light will illuminate and
remain constant until the central station has received the cancel report.
SOUNDER will sound if ANY area has the sounder on. This includes Entry delay, Exit delay, Chime, and
Alarm.