background image

6

[

U

]-[0]  ADJUST KEYPAD TONE

1) Press [

U

]-[0]

The LCD screen will prompt you to use the scroll keys located on
the right of the display to raise or lower the tone.

2) Use the up scroll key to raise the tone.
Use the down scroll key to lower the tone.

The keypad will emit a continuous tone to allow you to hear the
current selection. 

3) When the desired tone is reached, press the [#] key to set this tone and exit the mode.

[

U

]-[

x

]  VIEW ZONE STATUS

1)  Enter [

U

]-[

x

]

The LCD Screen will display the zone status.

2) Use the up and down scroll keys
to browse through the descriptions.

The LCD Screen will display the list of ALL zones in sequential
order by zone number

3) Press [#] to exit this function.

[

U

]-[3]  VIEW ALARM MEMORY

1)  Enter [

U

]-[3

The LCD Screen will display the zone description for the zones.

2) Use the up and down scroll keys
to browse through the alarm memory.

The LCD Screen will display the list in sequential order by zone
number.

3) Press [#] to exit this function.

[

U

]-[5]  CHANGING USER CODES

Note: For partitioned systems, someone changing the code of another person must have access to all or more
partitions than the user being changed.

1)  Enter [

U

]-[5

The LCD Screen will prompt for a code.

2)  Enter [master code]

The LCD Screen will prompt for a user Number.

3) Enter the 2 digit user number (always 2
digits, i.e. "03" for user 3)

The LCD screen will prompt for a new code.

4) Enter the new user code designated for that individual.  The sounder will beep  3 times if it rejects the code.

5) If another user code needs to be programmed, return to step 3.

6) To exit Code Programming, press [#] while the  LCD screen is prompting for a new user number.

[

U

]-[6]  ASSIGNING AUTHORITY LEVEL

Note: You must have authority to the partition you wish to add or remove from another person’s authority. 

1)  Enter [

U

]-[6]

The LCD Screen will prompt for a code.

2)  Enter [master code]

The LCD Screen will prompt for a user Number.

3) Enter the 2 digit user number (always 2
digits, i.e. "03" for user 3) 

The LCD screen will prompt for a new code. The LCD will now
prompt you for the first in the following list of attributes.

PROMPTS

If Prompt #1 ("Outputs used?") is
answered NO, the LCD will display the
four messages below.

If Prompt #1 ("Outputs used?") is
answered YES, the LCD will  display the
four messages below.

(#1)  Outputs used?

Open / Close Rprt?

Bypass enable?

Arm / Disarm?

Master code?

Output 4 enable?

Sched arm only?

Output 3 enable?

Arm only?

Output 2 enable?

Reserved

Output 1 enable?

Содержание NX-148

Страница 1: ... View 3 Programming Custom Messages 4 Set Keypad Options 4 Set Keypad Number Partition 5 Keypad Functions 5 7 Reading the Event Log 5 Set Elapsed Increments 5 Set System Time Date 5 Adjust Keypad Tone 6 View Zone Status 6 View Alarm Memory 6 Change User Codes 6 Assigning Authority Level 6 Partitioned System Operation 7 9 Service Display 9 10 Maximum Wire Run 11 Specifications Warranty Back NX 148 ...

Страница 2: ...he left and the segment number on the right The data will be displayed on the bottom line with the numbers 1 8 in the first 8 characters If the number appears this binary switch is on If a minus sign appears where the number should be this switch is off Toggle numbers on or off using the corresponding number digit 1 to toggle 1 8 to toggle 8 When the numbers are in the desired state enter the U ke...

Страница 3: ...module connected to the data terminal This allows these modules to be supervised by the control panel NOTE All modules should be connected and set to unique addresses prior to enrolling modules To enroll the modules enter the Program Mode of the NetworX control panel When the Program Mode is exited the control will enroll the devices The enrolling process takes about 12 seconds during which time t...

Страница 4: ... different custom message you must enable Custom Message Lock under the U 9 3 function U 9 3 SET KEYPAD OPTIONS 1 Enter U 9 3 The LCD Screen will prompt for a code 2 Enter program code The LCD will now prompt you through the options listed on the following chart The current state of the option will be shown in the lower right corner of the display Press U to exit the current state unchanged Otherw...

Страница 5: ...l now show the most recent event 3 To view the events from most recent to the oldest press the down scroll key 4 To view the events from the oldest to the newest press the up scroll key The display contains the following information Event User or Zone ID Date Month Day Indicates partition and U indicates an event not reported ß Time shown in 24 hour format This screen shows an opening of Partition...

Страница 6: ... user being changed 1 Enter U 5 The LCD Screen will prompt for a code 2 Enter master code The LCD Screen will prompt for a user Number 3 Enter the 2 digit user number always 2 digits i e 03 for user 3 The LCD screen will prompt for a new code 4 Enter the new user code designated for that individual The sounder will beep 3 times if it rejects the code 5 If another user code needs to be programmed r...

Страница 7: ...be entered into alarm memory and the internal log To exit at any time during this mode enter a user code Otherwise the Walk Test Mode will automatically exit after 15 minutes PARTITIONED SYSTEMS OPERATION The NX 148 can be programmed to operate all the system partitions simultaneously To set the multi partition mode use the U 9 3 function and answer YES to the question Master keypad NOTE U 1 follo...

Страница 8: ...lank Area Not Used or Authorized Dash Dash Area Not Ready Flashing Dash Area Ready to Force Arm Dash Flashing Area Armed Instant Area Dash Area Disarmed Ready to Arm Dash Area Area is Armed To disarm all of the areas press the x up scroll key To arm all of the areas press the down scroll y key To toggle a single area between the armed and disarmed conditions press U Area number For example if Area...

Страница 9: ... partition is selected SERVICE DISPLAY The following message will be displayed periodically if the security system requires service If you see this display press U 2 One or more of the following fault messages will be displayed Use the scroll keys to browse through them To exit the service messages press A short circuit of a control s power supply has occurred Open circuit has occurred on the bell...

Страница 10: ... of trouble on the bell or siren circuit A zone is tampered Press U to identify the tampered zone A wireless device has a low battery Press U to identify the zone A wireless or multiplexed zone device is not reporting to the control Press U to identify the zone A zone is experiencing some form of trouble probably wiring Press U to identify the zone The following chart provides the device numbers t...

Страница 11: ... the end of the wire When connecting more than one keypad to the end of the wire a heavier gauge wire will be required WHEN CONNECTED TO NX 8 WHEN CONNECTED TO NX 320 Length in feet Wire Gauge Wire Gauge 250 24 22 500 20 18 1000 18 16 1500 16 14 2500 14 12 SYSTEM NOTES ...

Страница 12: ...E PREPAID THE UNIT WILL BE REPAIRED AND RETURNED AT NO CHARGE FOR THE REMAINING 36 MONTHS OF WARRANTY THE CHARGE TO REPAIR OR REPLACE THIS UNIT WILL NOT EXCEED 10 00 PLUS SHIPPING AND HANDLING CADDX ASSUMES NO LIABILITY FOR CONSEQUENTIAL OR INDIRECT DAMAGE AND ACCEPTS NO RESPONSIBILITY FOR REPAIRING DAMAGE TO THE PRODUCT CAUSED BY MISUSE CARELESS HANDLING OR WHERE REPAIRS HAVE BEEN MADE BY OTHERS ...

Отзывы: