background image

3

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ ¥ ] ^ _

`

a b c d e f g h i

j k l m n o p q r s t u v w x y z {

|

}

 ž

!

" # $ % & '

(

)

U

+ ,

-

.

/ 0 1 2 3 4 5 6 7 8 9 :

; < = > ? @

 

ä

µ

<

× ¢ £

Ý

ö

ü

Œ

M

$

=

÷

NX-148  LIBRARY

ALARM

DELAY

EXTERIOR

HOUSE

MICROWAVE

ROOM

SMOKE

UP

AREA

DEN

FIRE

INFRARED

MOTION

RUMPUS

SOUND

UTILITY

AUDIO

DETECTOR

FRONT

INSTANT

NORTH

SAFE

SOUTH

VAULT

BACK

DINING

GAME

INTERIOR

NURSERY

SENSOR

STAIRS

WAREHOUSE

BATHROOM

DOOR

GARAGE

JUNK

OFFICE

SHOCK

STORAGE

WEST

BEAM

DOWN

GLASSBREAK

KITCHEN

PANIC

SHOP

STUDY

WINDOW

BEDROOM

DURESS

GUEST

LIBRARY

PANTRY

SIDE

TAMPER

WING

BUTTON

EAST

HALL

LIGHT

PHONE

SKYLIGHT

TELEVISION

WIRELESS

CEILING

EMERGENCY

HEAT

LIVING

PIR

SLIDING

TROUBLE

YARD

CLOSET

EXIT

HOLDUP

MASTER

PORCH

SMALL

TV

ZONE

LOADING FACTORY DEFAULTS

To load the factory defaults, enter the Program Mode using the procedure on page 2, then type [9]-[1]-[0]-[#]. The
keypad will beep 3 times indicating that the loading is in progress. The loading takes about 6 seconds.  To load the
factory defaults for the LCD keypad, enter the Program Mode from a 

different keypad (does not have to be LCD

keypad), and follow the procedures mentioned previously. 

ENROLLING MODULES AND KEYPADS

For supervision purposes, the NetworX control panel has the ability to automatically find and store in its memory the
presence of all keypads, zone expanders, wireless receivers, and any other module connected to the data terminal.
This allows these modules to be supervised by the control panel. NOTE: All modules should be connected and set
to unique addresses prior to enrolling modules. To enroll the modules, enter the Program Mode of the NetworX
control panel.  When the Program Mode is exited, the control will enroll the devices.  The enrolling process takes
about 12 seconds, during which time the "Service Screen" will be displayed.  Once a module is enrolled, if it is not
detected by the control, the "Service Screen” will be displayed.

PROGRAMMING THE NX-148 LCD  KEYPADS

This section describes how to program the address and partition of each keypad, as well as the options that are
available.  The address of the keypad is important because this is how the panel supervises the keypads. The factory
default for the Master code is [1]-[2]-[3]-[4] when using a 4-digit code, or  [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code.  The
factory default for the "Go To Program" code is [9]-[7]-[1]-[3] when using  a 4-digit code, or [9]-[7]-[1]-[3]-[0]-[0] for a
6-digit code.

[

U

]-[9]-[1]  ADJUSTING THE VIEW / BRIGHTNESS OF THE LCD

1)  Enter [

U

]-[9]-[1]

The LCD Screen will prompt for the "Go To Program" code.

2)  Enter [master code]

The LCD will now prompt you to raise or lower the viewing angle.  Using the scroll
keys to the right of the LCD, you can raise or lower the viewing angle of the text. 

3) To advance to the
Brightness option, press  [

U

]

The LCD will prompt you to brighten or dim the LCD lighting.  Use the scroll keys
again to adjust to desired brightness.  When completed, exit by pressing  [

U

].

Содержание NX-148

Страница 1: ... View 3 Programming Custom Messages 4 Set Keypad Options 4 Set Keypad Number Partition 5 Keypad Functions 5 7 Reading the Event Log 5 Set Elapsed Increments 5 Set System Time Date 5 Adjust Keypad Tone 6 View Zone Status 6 View Alarm Memory 6 Change User Codes 6 Assigning Authority Level 6 Partitioned System Operation 7 9 Service Display 9 10 Maximum Wire Run 11 Specifications Warranty Back NX 148 ...

Страница 2: ...he left and the segment number on the right The data will be displayed on the bottom line with the numbers 1 8 in the first 8 characters If the number appears this binary switch is on If a minus sign appears where the number should be this switch is off Toggle numbers on or off using the corresponding number digit 1 to toggle 1 8 to toggle 8 When the numbers are in the desired state enter the U ke...

Страница 3: ...module connected to the data terminal This allows these modules to be supervised by the control panel NOTE All modules should be connected and set to unique addresses prior to enrolling modules To enroll the modules enter the Program Mode of the NetworX control panel When the Program Mode is exited the control will enroll the devices The enrolling process takes about 12 seconds during which time t...

Страница 4: ... different custom message you must enable Custom Message Lock under the U 9 3 function U 9 3 SET KEYPAD OPTIONS 1 Enter U 9 3 The LCD Screen will prompt for a code 2 Enter program code The LCD will now prompt you through the options listed on the following chart The current state of the option will be shown in the lower right corner of the display Press U to exit the current state unchanged Otherw...

Страница 5: ...l now show the most recent event 3 To view the events from most recent to the oldest press the down scroll key 4 To view the events from the oldest to the newest press the up scroll key The display contains the following information Event User or Zone ID Date Month Day Indicates partition and U indicates an event not reported ß Time shown in 24 hour format This screen shows an opening of Partition...

Страница 6: ... user being changed 1 Enter U 5 The LCD Screen will prompt for a code 2 Enter master code The LCD Screen will prompt for a user Number 3 Enter the 2 digit user number always 2 digits i e 03 for user 3 The LCD screen will prompt for a new code 4 Enter the new user code designated for that individual The sounder will beep 3 times if it rejects the code 5 If another user code needs to be programmed r...

Страница 7: ...be entered into alarm memory and the internal log To exit at any time during this mode enter a user code Otherwise the Walk Test Mode will automatically exit after 15 minutes PARTITIONED SYSTEMS OPERATION The NX 148 can be programmed to operate all the system partitions simultaneously To set the multi partition mode use the U 9 3 function and answer YES to the question Master keypad NOTE U 1 follo...

Страница 8: ...lank Area Not Used or Authorized Dash Dash Area Not Ready Flashing Dash Area Ready to Force Arm Dash Flashing Area Armed Instant Area Dash Area Disarmed Ready to Arm Dash Area Area is Armed To disarm all of the areas press the x up scroll key To arm all of the areas press the down scroll y key To toggle a single area between the armed and disarmed conditions press U Area number For example if Area...

Страница 9: ... partition is selected SERVICE DISPLAY The following message will be displayed periodically if the security system requires service If you see this display press U 2 One or more of the following fault messages will be displayed Use the scroll keys to browse through them To exit the service messages press A short circuit of a control s power supply has occurred Open circuit has occurred on the bell...

Страница 10: ... of trouble on the bell or siren circuit A zone is tampered Press U to identify the tampered zone A wireless device has a low battery Press U to identify the zone A wireless or multiplexed zone device is not reporting to the control Press U to identify the zone A zone is experiencing some form of trouble probably wiring Press U to identify the zone The following chart provides the device numbers t...

Страница 11: ... the end of the wire When connecting more than one keypad to the end of the wire a heavier gauge wire will be required WHEN CONNECTED TO NX 8 WHEN CONNECTED TO NX 320 Length in feet Wire Gauge Wire Gauge 250 24 22 500 20 18 1000 18 16 1500 16 14 2500 14 12 SYSTEM NOTES ...

Страница 12: ...E PREPAID THE UNIT WILL BE REPAIRED AND RETURNED AT NO CHARGE FOR THE REMAINING 36 MONTHS OF WARRANTY THE CHARGE TO REPAIR OR REPLACE THIS UNIT WILL NOT EXCEED 10 00 PLUS SHIPPING AND HANDLING CADDX ASSUMES NO LIABILITY FOR CONSEQUENTIAL OR INDIRECT DAMAGE AND ACCEPTS NO RESPONSIBILITY FOR REPAIRING DAMAGE TO THE PRODUCT CAUSED BY MISUSE CARELESS HANDLING OR WHERE REPAIRS HAVE BEEN MADE BY OTHERS ...

Отзывы: