3
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ ¥ ] ^ _
`
a b c d e f g h i
j k l m n o p q r s t u v w x y z {
|
}
!
" # $ % & '
(
)
U
+ ,
-
.
/ 0 1 2 3 4 5 6 7 8 9 :
; < = > ? @
•
ä
µ
<
× ¢ £
Ý
ö
!
ü
M
$
=
÷
NX-148 LIBRARY
ALARM
DELAY
EXTERIOR
HOUSE
MICROWAVE
ROOM
SMOKE
UP
AREA
DEN
FIRE
INFRARED
MOTION
RUMPUS
SOUND
UTILITY
AUDIO
DETECTOR
FRONT
INSTANT
NORTH
SAFE
SOUTH
VAULT
BACK
DINING
GAME
INTERIOR
NURSERY
SENSOR
STAIRS
WAREHOUSE
BATHROOM
DOOR
GARAGE
JUNK
OFFICE
SHOCK
STORAGE
WEST
BEAM
DOWN
GLASSBREAK
KITCHEN
PANIC
SHOP
STUDY
WINDOW
BEDROOM
DURESS
GUEST
LIBRARY
PANTRY
SIDE
TAMPER
WING
BUTTON
EAST
HALL
LIGHT
PHONE
SKYLIGHT
TELEVISION
WIRELESS
CEILING
EMERGENCY
HEAT
LIVING
PIR
SLIDING
TROUBLE
YARD
CLOSET
EXIT
HOLDUP
MASTER
PORCH
SMALL
TV
ZONE
LOADING FACTORY DEFAULTS
To load the factory defaults, enter the Program Mode using the procedure on page 2, then type [9]-[1]-[0]-[#]. The
keypad will beep 3 times indicating that the loading is in progress. The loading takes about 6 seconds. To load the
factory defaults for the LCD keypad, enter the Program Mode from a
different keypad (does not have to be LCD
keypad), and follow the procedures mentioned previously.
ENROLLING MODULES AND KEYPADS
For supervision purposes, the NetworX control panel has the ability to automatically find and store in its memory the
presence of all keypads, zone expanders, wireless receivers, and any other module connected to the data terminal.
This allows these modules to be supervised by the control panel. NOTE: All modules should be connected and set
to unique addresses prior to enrolling modules. To enroll the modules, enter the Program Mode of the NetworX
control panel. When the Program Mode is exited, the control will enroll the devices. The enrolling process takes
about 12 seconds, during which time the "Service Screen" will be displayed. Once a module is enrolled, if it is not
detected by the control, the "Service Screen” will be displayed.
PROGRAMMING THE NX-148 LCD KEYPADS
This section describes how to program the address and partition of each keypad, as well as the options that are
available. The address of the keypad is important because this is how the panel supervises the keypads. The factory
default for the Master code is [1]-[2]-[3]-[4] when using a 4-digit code, or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code. The
factory default for the "Go To Program" code is [9]-[7]-[1]-[3] when using a 4-digit code, or [9]-[7]-[1]-[3]-[0]-[0] for a
6-digit code.
[
U
]-[9]-[1] ADJUSTING THE VIEW / BRIGHTNESS OF THE LCD
1) Enter [
U
]-[9]-[1]
The LCD Screen will prompt for the "Go To Program" code.
2) Enter [master code]
The LCD will now prompt you to raise or lower the viewing angle. Using the scroll
keys to the right of the LCD, you can raise or lower the viewing angle of the text.
3) To advance to the
Brightness option, press [
U
]
The LCD will prompt you to brighten or dim the LCD lighting. Use the scroll keys
again to adjust to desired brightness. When completed, exit by pressing [
U
].