INSTALLATION
Page 3-10
To attach a UTP or STP lobe segment to a TRXI network port:
1.
Insert the RJ45 connector from each twisted pair segment into the
desired RJ45 network lobe port number on the TRXI as shown in
Figure 3-10.
Figure 3-10. TRXI Network Ports
2.
The associated Port Status LED will light green when the station
boots up. If the LED is not lit, perform each of the following steps
until it is:
a.
Check that the device at the other end of the twisted pair
segment is on and the network interface driver is initialized.
b.
Verify that the RJ45 connector on the twisted pair segment has
the proper pinouts.
c.
Check the cable for continuity.
d.
Check that the twisted pair connection meets dB loss and cable
specifications outlined in Chapter 2.
e.
Check Local Management to ensure the port is enabled.
If a link still has not been established, contact Cabletron Systems
Technical Support.
RI
RO
6
5
4
3
2
1
18
17
16
15
14
13
TPIM-T4
LNK
TPIM-T4
LNK