background image

9033260-01

SmartSTACK

ELS100-S24TX2M

FAST ETHERNET SWITCH

USER GUIDE

Содержание SmartSTACK ELS100-S24TX2M

Страница 1: ...9033260 01 SmartSTACK ELS100 S24TX2M FAST ETHERNET SWITCH USER GUIDE...

Страница 2: ......

Страница 3: ...RMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HA VE KNOWN THE POSSIBILITY OF SUCH DAMAGES 2000 by Cabletron Systems Inc P O Box 5005 Rochester NH 03866 5005 All...

Страница 4: ...inwhich case the user will be required to correct the interference at his own expense WARNING Changes or modificationsmade to this device which are not expressly approved by the party responsible for...

Страница 5: ...one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except as permitted by t...

Страница 6: ...er software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is...

Страница 7: ...to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of the Program except...

Страница 8: ...er software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is...

Страница 9: ...You have the right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this License Agreement You may not copy reproduce or transmit any part of t...

Страница 10: ...ter software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects i...

Страница 11: ...0082 1 EN 60950 Equipment Type Environment Netw orking Equipment for use in a Commercial or Light Industrial Environment We the undersigned hereby declare under our sole responsibility that the equipm...

Страница 12: ......

Страница 13: ...rameter Storage 8 Configuration and Management Interfaces 8 RMON 9 Port Mirroring 9 Auto negotiation 10 BootP 10 LEDs 10 Full Duplex Mode 10 Flow Control 11 Virtual LANs VLANs 11 Class of Service 11 P...

Страница 14: ...100Base FX 1000Base SX LX Fiber Ports 28 APPENDIX A TECHNICAL SPECIFICATIONS 29 General 29 Standards Compliance 29 Regulatory Compliance 29 Data Rate 29 Environmental Specifications 29 Electrical Spe...

Страница 15: ...ion Control Protocol Internet Protocol TCP IP and Simple Network Management Protocol SNMP Conventions This section describes the conventions used in this guide Message Formats Two types of messages id...

Страница 16: ...ation Describes the content of your switch shipment lists site requirements and provides mounting instructions Instructions for making connections and powering up the switch are provided as well Appen...

Страница 17: ...ntegrity In this mode the entire packet must be received into a port buffer and checked for validity before being forwarded This prevents errors from being propagated throughout the network This switc...

Страница 18: ...n ventilation and cooling for internal switch components Features Ports 24 dual speed 10Base T 100Base TX ports using RJ 45 connectors MDI X 3 slots for optional modules 1 redundant power unit socket...

Страница 19: ...488 000 pps 1000 Mbps Network Management SNMP compliant agent MIB II RFC 1213 Bridge MIB RFC 1493 Ethernet like MIB RFC 1643 RMON Statistics History Alarm and Event groups RFC 1757 Interface Evolutio...

Страница 20: ...t a Management Module is installed and in operational mode Link LEDs Yellow indicates a 10 Mbps link green indicates a 100 Mbps link off indicates no link and flashing indicates that the port has been...

Страница 21: ...le Components 100Base FX MMF Ports Twomulti mode fiber ports usingSC connectors foruplink See100Base FX 1000Base SX LXFiber Ports onpage28fora detaileddescription 100Base FX SMF Ports Onesingle mode f...

Страница 22: ...he 32 cm cable and the 1 m cable can be ordered separately if required Management Console port Male DB 9 connector configured as a null modem connection for serial out of band management using the con...

Страница 23: ...reated through the switch with the Spanning Tree Protocol choosing a single path at any given time and disabling all others If the chosen path fails for any reason a disabled alternative is activated...

Страница 24: ...stack can be managed using any of the following methods Serial console out of band An RS 232 connection using a DB 9 connector is included on the Management Module for system management Serial console...

Страница 25: ...number of packets broadcasts collisions errors and distribution of packet sizes History a function that collects historical statistics based on user defined sampling intervals The statistical informat...

Страница 26: ...4TX2M switch uses BootP to automatically configure IP address information without requiring access to the console menus BootP operation is configurable using the console interface menus the on board W...

Страница 27: ...ELS100 S24TX2M switch supports Class of Service attributes per the IEEE 802 1p standard using a priority queuing mechanism This feature ensures that traffic during congestion periods will not interfer...

Страница 28: ...bled Port Configuration Flow Control Disabled Speed and Duplex Auto Admin Enabled Port Priority Default Ingress User Priority 0 Spanning Tree Algorithm Active Aging Time 300 Bridge Priority 32768 Forw...

Страница 29: ...Product Overview 13 Virtual LANs Acceptable VLAN Frame Type All Configurable PVID Tagging Yes GVRP Disabled Untagged VLAN Group Assignment 1 VLAN Ingress Filtering False VLAN Learning SVL Parameter De...

Страница 30: ...k segmentation and traffic prioritization The ELS100 S24TX2M switch is ideal for meeting the needs of today s high performance networks The switch s low cost and high port count makes it attractive an...

Страница 31: ...t connections to servers by connecting each to a dedicated switch port Figure 1 4 Users can be accommodated through connections to hubs both at 10Mbps and 100Mbps speeds through 10Mbps switches with 1...

Страница 32: ...ver access Figure 1 5 Workgroup hubs are provided with a single connection to the switch while servers are put on dedicated 100 Mbps ports Routers and other networking devices can connect off of the s...

Страница 33: ...t table shelf surface or an optional 19 in 48 3 cm equipment rack Use an EIA standard equipment rack that is grounded and physically secure Power source Provide a power source within six feet 1 8 m of...

Страница 34: ...front panel RJ 45 ports visibility of the port LEDs and access tothe rear panel modules and power cord Make surethat the mountingsurface can safely support the switch stack and that there is adequate...

Страница 35: ...switch using two 2 of the supplied screws Repeat this step for the other side of the switch 2 Slide the switch intothe rack and align the holes inthe rack mounting ears with the holes in the rack rail...

Страница 36: ...the stack or rack Form a simple chain starting at the DOWN port on the first switch and ending at the UP port on the last switch Figure 2 2 Connecting Switches to the Stack s Backplane Stacking Modul...

Страница 37: ...her of the two lower slots on the rear panel of the switch A Management Module can be installed in the upper slot on the rear of the switch 3 Before opening the package that contains the module touch...

Страница 38: ...s through its initialization process See Powering the Switch on page 25 The console port connector is configured as a male null modem connection using a male DB 9 see Table A 1 for pinouts A standard...

Страница 39: ...our PC i e COM 1 4 then set communications to 8 data bits 1 stop bit no parity 19200 bps and no flow control In Band Connections Priorto accessingtheManagement Module via a network connection you must...

Страница 40: ...ation for the Management Module available for the ELS100 S24TX2M Table 2 2 Management Module Part Number Functions Description ELS100 SMGMT RMON SNMP Web Manage ment SNMPagent moduleused tomanage thes...

Страница 41: ...are displayed on the screen If you want to display the results of the tests after the switch has been turned on turn the power to the switch off then back on The switch performs two basic types of tes...

Страница 42: ...ts and length constraints for the Gigabit Ethernet short wavelength fiber interface on the fiber optic media module Table 2 5 1000Base SX Fiber Specifications Interface Type Cable Requirement Maximum...

Страница 43: ...n to 10Base T or 100Base TX network segments or end stations These UTP connections meet the requirements of ISO 8877 specified by 10Base T Section 14 of the IEEE 802 3 specification Workstations or se...

Страница 44: ...The 100Base FX and 1000Base SX LX ports use SC fiber connectors The fiber connectors are configured as a receive RX transmit TX pair Table 2 7 Fiber Uplink Modules Part Number Functions Description EP...

Страница 45: ...ause 25 IEEE 802 3u 100Base FX IEEE 802 3z 1000Base SX 1000Base LX IEEE 802 3x Flow Control EIA RS 232C DTE to DCE EIA RS 310C 19 rackmount Regulatory Compliance Safety UL 1950 CSA C22 2 No 950 73 23...

Страница 46: ...ical Specifications Input voltage 100 240 VAC Input frequency 50 60 Hz Maximum power consumption 80 VA Physical Specifications Height 2 5 in 6 4 cm Length 11 2 in 28 5 cm Width 17 3 in 44 cm mountable...

Страница 47: ...1 RS 232 Console Port Pin Assignments 10Base T and 100Base TX Ports Table A 2 shows the 10Base T 100Base TX pinouts These ports are wired MDI X All undefined pins are not used Table A 2 10Base T 100B...

Страница 48: ...the switch Power cord sets for use in other countries must meet the requirements of the country where you use the switch For more information on power cord set requirements contact your Cabletron Sys...

Страница 49: ...pler and wall plug must bear the certification mark of the agency responsible for evaluation in the country where it will be used Country Accredited Agency See Notes Australia EANSW 1 Austria OVE 1 Be...

Страница 50: ...A 5 15P 15A 125V or NEMA 6 15P 15A 250V configuration Note 3 Appliance coupler flexible cord and wall plug must bear a T mark and registration number in accordance with the Japanese Dentori Law Flexib...

Страница 51: ...trol function on the port from which the packet entered the switch in this case port X Since port X is configured with Flow Control set to Enabled the switch responds by initiating a pause frame full...

Страница 52: ......

Страница 53: ...egory 5 CRC Cyclic Redundancy Check CSMA CD Carrier Sense Multiple Access Collision Detection DCE Data Communications Equipment modem DSR Data Send Ready DTE Data Terminal Equipment DTR Data Terminal...

Страница 54: ...ELS100 S24TX2M SNMP Simple Network Management Protocol TCP IP Transmission Control Protocol Internet Protocol TFTP Trivial File Transfer Protocol TXD Transmit Data UTP Unshielded Twisted Pair VLAN Vi...

Страница 55: ...backplane 20 console port 8 22 31 contents of package 17 cooling requirements 18 copper cables 26 ports 4 crossover cable 27 32 D data rates 29 DB 9 connector 8 default settings 12 description of swit...

Страница 56: ...ears 19 mounting the switch in a rack 19 on a table or shelf 18 multi mode fiber 26 28 N network applications 14 network management features 3 network traffic analysis 9 non volatile Flash memory 8 n...

Страница 57: ...Tree Protocol 7 stacking connecting switches 20 module features 2 6 stack cables 20 standards compliance IEEE 29 Status LEDs module 4 store and forward switching 7 switch description 1 switch ID 4 T T...

Страница 58: ......

Страница 59: ......

Страница 60: ...150384 102 R01...