SmartCell ZX-250 User Guide 4-5
Switch Administration
ATM Routing
4.2.2
UNI Routes
Use the
add ATMRoute
command to create UNI routes. For example, connect an end station adapter (with MAC address
00:11:22:33:44:55) to port A2 of the SmartCell ZX-250. If the adapter does not support ILMI or its ILMI is
incompatible with the SmartCell ZX-250, you must create a static UNI route between the adapter and port A2 of the
SmartCell ZX-250.
s•
Enter the
show netprefix
command to obtain the netprefix of port A2
SmartCell ZX # show netprefix
PortNumber(ALL) : a2
Port# NetPrefix
============================================================================
A2 39:00:00:00:00:00:00:00:00:00:14:59:00
SmartCell ZX #
¢•
Reconfigure the adapter with an ATM address made from the netprefix of port A2 and the adapter’s
MAC address: 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55:00.
••
Use the
add ATMRoute
command to create a static UNI route that specifies port A2 and the adapter’s
new ATM address.
SmartCell ZX # add atmroute
PortNumber(A1) : a2
AtmAddress() : 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55:00
PrefixLength(152) :
Index(0) :
Type(Internal) :
Scope(0) :
MetricsTag(0) :
SmartCell ZX #
T•
Enter the
show ATMRoute
command to check that the UNI route was added.
SmartCell ZX # show atmroute
AddressNumber(ALL) :
No. Port Route Address Type Protocol
================================================================================
1 B4 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:80 I MGMT
2 B4 39:00:00:00:00:00:00:00:00:00:14:41:80:00:20:d4:14:41:81 I MGMT
3 -- 39:00:00:00:00:00:00:00:00:00:14:59:00 I PNNI
4 A2 39:00:00:00:00:00:00:00:00:00:14:59:00:00:11:22:33:44:55 I MGMT
5 -- 39:00:00:00:00:00:00:00:00:00:28:e9:80 I PNNI
6 -- 39:00:00:00:00:00:00:00:00:00:28:f5:00 I PNNI
7 B4 47:00:79:00:00:00:00:00:00:00:00:00:00:00:a0:3e:00:00:01 I MGMT
8 B2 52:00:00:00:00:00:00:00:00:00:14:51:80 I MGMT
SmartCell ZX #SmartCell ZX #
The UNI route appears in the table as route number four (No. 4).
2
p›F
For UNI routes to work with certain devices, ILMI may also need to be disabled
on the SmartCell ZX-250. Use the
set PortConfig
command to disable ILMI on
the SmartCell ZX-250 on a per-port basis.
Содержание SmartCell ZX-250
Страница 12: ...xii SmartCell ZX 250 User Guide Table of Contents...
Страница 16: ...xvi SmartCell ZX 250 User Guide List of Tables...
Страница 18: ...1 2 SmartCell ZX 250 User Guide Introduction...
Страница 46: ...3 8 SmartCell ZX 250 User Guide Creating an Emulated LAN IP Over ATM and LANE...
Страница 92: ...4 46 SmartCell ZX 250 User Guide Performing Hardware Maintenance Switch Administration...
Страница 98: ...5 6 SmartCell ZX 250 User Guide Troubleshooting Congestion Troubleshooting...
Страница 110: ...A 12 SmartCell ZX 250 User Guide Acronyms...
Страница 124: ...C 8 SmartCell ZX 250 User Guide Managing the SmartCell ZX 250 Agent Support...