INSTALLING THE SEHI
SEHI USER’S GUIDE
3-7
Figure 3-6. Installing the SEHI in the Rack
If the installation requires that the SEHI is to be stacked, proceed to
Section 3.3.5. Otherwise, continue by connecting power as described in
Section 3.4.
3.3.5 Stacking the SEHI
The rear panel of the SEHI has an Interconnect Bus Out Port (male
connector). Daisy chain units together using Cabletron Systems
HubSTACK Interconnect cables. Table 3-1 describes each cable.
To stack the SEHI together with an SEH non-intelligent hub:
1. Attach the SEHI HubSTACK Interconnect cable to the “OUT” port on
the rear panel of the SEHI as shown in Figure 3-7.
2. Attach the other end of the SEHI HubSTACK Interconnect cable to
the “IN” port on the rear panel of the SEH.
Table 3-1. HubSTACK Interconnect Cables
Part
Number
Description
Application
9380110
12" HubSTACK
Interconnect Cable
SEH to SEH connections
9380111
18" HubSTACK
Interconnect Cable
SEHI to SEH connections
HubSTACK
10BASE-T HUB
WITH
LANVIEW®
SEHI-24
Screws (4)
19-Inch Rack