9

9M426-02 Module Specific Information

 

System Resources Screen Fields

 

The following information brießy explains each System Resources Screen Þeld.

 

CPU Type

 

 (Read-only)

 

Indicates the microprocessor, and the speed (in MHz) at which it is operating.

 

Flash Memory Installed/Available 

 

(Read-only)

 

Indicates the amount of FLASH memory installed in the module and how much 
is currently available.

 

DRAM Installed/Available

 

 (Read-only)

 

Indicates the amount of DRAM installed in the module and how much of it is 
currently available.

 

NVRAM Installed/Available 

 

(Read-only)

 

Indicates the amount of NVRAM installed in the module and how much of it is 
currently available.

 

Current Switch Utilization 

 

(Read-only)

 

Shows how much (percentage) of the switch capacity of the module is currently 
being used.

 

Peak Switch Utilization 

 

(Read-only)

 

Shows the peak percentage of maximum switching capacity since the last reset.

 

Reset Peak Switch Utilization 

 

(Toggle)

 

Allows you to reset the Peak Switch Utilization Þeld. The switch may be set to 
either YES or NO. YES resets the Peak Switch Utilization Þeld to zero.

Содержание MMAC-Plus 9M426-02

Страница 1: ...9032253 01 SmartSwitch 9000 9M426 02 Local Management Appendix...

Страница 2: ......

Страница 3: ...FDDI WAN etc depending on the HSIM installed in the module Modifying Fields and User Privileges To modify elds on this module you must have read write or super user privileges If you have read only pr...

Страница 4: ...eral Con guration Screen Table 1 9M426 02 Module Interfaces Interface Number Interface Name Interface Description 1 SMB1 1 Mbps System Management Bus 2 SMB10 10 Mbps System Management Bus 3 HOST 4 INB...

Страница 5: ...re 1 9M426 02 LM Screen Hierarchy System Resources HSIM Configuration Screens Flash Download Broadcast Suppression General Configuration SNMP Community Names SNMP Traps Switch Configuration Module Spe...

Страница 6: ...BLED 2 disabled ENABLED 3 disabled ENABLED 4 00 00 1D BA DB B0 forwarding ENABLED 5 disabled ENABLED 6 disabled ENABLED 7 disabled ENABLED 8 disabled ENABLED SAVE 9 16 EXIT RETURN The port numbering f...

Страница 7: ...t Read Only Lists each switch port on the module MAC Address Read Only Displays the hardware address assigned to each listed port State Read Only Displays the current state of each listed interface Th...

Страница 8: ...ed from the Blocking state when the Spanning Tree Algorithm and Protocol determines that the interface should participate in forwarding traf c The Listening state is exited in any of three ways When a...

Страница 9: ...te The Forwarding state is exited in either of two ways When a BPDU is received on this port or another port the Blocking state is then entered Through management action either the Blocking or the Dis...

Страница 10: ...igure 3 System Resources Screen MMAC Plus Local Management System Resources Module Name 9M426 02 Firmware Revision 01 00 03 Slot Number 2 BOOTPROM Revision 01 01 00 CPU Type i960 HT 75MHz Flash Memory...

Страница 11: ...mount of DRAM installed in the module and how much of it is currently available NVRAM Installed Available Read only Indicates the amount of NVRAM installed in the module and how much of it is currentl...

Страница 12: ...fic Information 10 HSIM Configuration Screens For complete information about HSIMs refer to the HSIM User s Guides available in Portable Document Format from the World Wide Web at the following site h...

Страница 13: ...le will reboot after the download Figure 4 Flash Download Screen MMAC Plus Local Management Flash Download Module Name 9M426 02 Firmware Revision 01 00 03 Slot Number 2 BOOTPROM Revision 01 01 00 Down...

Страница 14: ...s performed this eld toggles between YES and NO If YES is selected the module reboots after the download is completed The module stores the new rmware image in FLASH memory When the module is reset th...

Страница 15: ...highlight EXECUTE at the bottom of the screen and press the Enter key The message TFTP DOWNLOAD WILL COMMIT TO FLASH REBOOT IN PROGRESS displays in the event message line at the top of the screen and...

Страница 16: ...of the screen and the new image is downloaded into FLASH memory Using BOOTP to Download Image File To download an image le using BOOTP 1 Use the arrow keys to highlight the Download Method eld 2 Press...

Страница 17: ...the forwarding of broadcast packets You can set limits Figure 5 Broadcast Suppression Screen MMAC Plus Local Management Broadcast Suppression Module Name 9M426 02 Firmware Revision 01 00 03 Slot Numb...

Страница 18: ...eak Rate Read only The maximum number of broadcast packets received on this port Time Since Peak Read only The time in hours minutes and seconds since the peak occurred Threshold Read only The upper l...

Страница 19: ...en the devices Figure 6 SmartTrunk Configuration Screen 03 17 1998 14 58 34 MMAC Plus Local Management SmartTrunk Configuration Screen Module Name 9M426 02 Firmware Revision 01 00 03 Slot Number 2 BOO...

Страница 20: ...WORK connections to participate in SmartTrunking To change a port s connection type press the Space Bar once The desired value appears in the eld SmartTrunk State Read only Displays the current operat...

Страница 21: ...bout frames received transmitted ltered and forwarded Figure 7 Switch Statistics Screen MMAC Plus Local Management Switch Statistics Module Name 9M426 02 Firmware Revision 01 00 03 Slot Number 2 BOOTP...

Страница 22: ...by this port Frames Txmtd Read Only Displays the number of frames transmitted by this port Frames Fltrd Read Only Displays the number of frames ltered by this port Frames Frwded Read Only Displays the...

Страница 23: ...e 9M426 02 Firmware Revision 01 00 03 Slot Number 2 BOOTPROM Revision 01 01 00 Interface 4 Name INB InOctets 0 Address 00 00 1D BA DB AE InUnicast 0 Last Change 00 days 00 00 00 InNonUnicast 0 Admin S...

Страница 24: ...ave been received that were sent to a single address InNonUnicast Read Only Displays the total number of frames that have been received that were delivered to a broadcast or multicast address InDiscar...

Страница 25: ...y Displays the length of the frames queue The eld represents the total number of frames that can be contained in queue Address Read Only Displays the MAC address of the interface that is currently bei...

Страница 26: ...EAR COUNTERS Command Use this command to reset all statistic counters to zero Viewing Statistics for Another Interface Use the following procedure to view statistics for another interface 1 Highlight...

Отзывы: