Rack-mounting an FN10
The table below describes some general considerations you should be
aware of before mounting a FN10 in a rack assembly.
The FN10 can be rack-mounted in a standard 19-inch equipment cabinet.
To mount the FN10 in a rack assembly, apply the following steps:
1. Attach the rack-mount brackets to either side of the FN10 chassis.
Table 2-3
General Considerations for Mounting a FN10
Consideration
Discussion
Temperature
Since the temperature within a rack assembly may
be higher than the ambient room temperature,
make sure the rack-environment temperature is
within the Operating Temperature range specified
in Appendix A.
Air Flow
Make sure there is at least 2 inches (or more) on
both sides of the FN10 to allow for adequate air
flow.
Mechanical Loading
Do not place equipment on top of a rack-mounted
FN10.
Circuit Overloading
Make sure the power supply circuit to the rack
assembly is not overloaded.
Grounding (Earthing)
Rack-mounted equipment should be grounded. In
addition to the direct connections to the main power
supplies, make sure all the other supply
connections are also grounded.
Содержание Fast Network 10
Страница 2: ......
Страница 30: ...Chapter 1 Introduction Page 1 20 Fast Network 10 User Guide...
Страница 42: ...Chapter 2 Unpacking and Installing Your FN10 Page 2 12 Fast Network 10 User Guide...
Страница 80: ...Chapter 4 Monitoring and Managing Your FN10 Page 4 20 Fast Network 10 User Guide...
Страница 104: ...Chapter 5 FN10 Filters Page 5 24 Fast Network 10 User Guide...
Страница 118: ...Appendix A Technical Specifications Page A 6 Fast Network 10 User Guide...