General Configuration Screen
6H122-16 User’s Guide
5-45
Figure 5-19
Configuration Warning Screen
5.
Use the arrow keys to highlight the YES command. Press ENTER.
The changes are saved and the module reboots.
5.15.2
Setting the Subnet Mask
If the management workstation that is to receive SNMP traps from the
6H122-16 is located on a separate subnet, the subnet mask for the
6H122-16 must be changed from its default.
To change the subnet mask from its default, perform the following steps:
1.
Use the arrow keys to highlight the Subnet Mask field.
2.
Enter the subnet mask into this field using Decimal Dotted Notation
(DDN) format.
For example: 255.255.255.0
3.
Press ENTER. If the subnet mask is valid, the cursor returns to the
beginning of the Subnet Mask field. If the entry is not valid, the Event
Message Line displays “INVALID SUBNET MASK OR FORMAT
ENTERED”. Local Management does not alter the current value, but
it does refresh the Subnet Mask field with the previous value.
4.
Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in
Figure 5-20
displays.
WARNING!
174252
YOU HAVE ELECTED TO SAVE ONE OR MORE CONFIGURATION
ITEMS THAT REQUIRE RESETTING THIS MODULE.
ARE YOU SURE YOU WANT TO CONTINUE?
YES
NO
Содержание 6H122-16
Страница 2: ......
Страница 8: ...Notice vi 6H122 16 User s Guide...
Страница 40: ...Chapter 4 Troubleshooting 4 8 6H122 16 User s Guide...
Страница 148: ...Chapter 5 Local Management 5 108 6H122 16 User s Guide...
Страница 154: ...Appendix B Mode Switch Bank Settings B 4 6H122 16 User s Guide...
Страница 158: ...Index Index 4 6H122 16 User s Guide...