Troubleshooting Checklist
6H122-16 User’s Guide
4-5
4.2
TROUBLESHOOTING CHECKLIST
If the 6H122-16 is not working properly, refer to
Table 4-3
for a checklist
of possible problems, causes, and recommended actions to resolve the
problem.
Table 4-3
Troubleshooting Checklist
Problem
Possible Cause
Recommended Action
All LEDs are OFF.
Loss of Power to the 6C105
chassis.
Check the proper
connection of the power
cable and its access to a
live outlet.
The 6H122-16 not properly
installed.
Check the installation. Refer
to
Chapter 3
.
No Local
Management
Password screen.
Autobaud enabled, but baud
rate has not been detected.
Press ENTER (RETURN)
(may take up to four times).
Terminal setup is not
correct.
Refer to
Chapter 5
for
proper setup procedures.
Improper console cable
pinouts.
Refer to
Appendix A
for
proper console port pinouts.
Cannot contact the
6H122-16 from
in-band
management.
Improper Community
Names Table.
Refer to
Section 5.8
for Community Names
Table setup.
The 6H122-16 does not
have an IP address.
Refer to
Section 5.15.1
for
IP address assignment
procedure.
Port is disabled.
Enable port.
No link to device.
Check link to device.
Содержание 6H122-16
Страница 2: ......
Страница 8: ...Notice vi 6H122 16 User s Guide...
Страница 40: ...Chapter 4 Troubleshooting 4 8 6H122 16 User s Guide...
Страница 148: ...Chapter 5 Local Management 5 108 6H122 16 User s Guide...
Страница 154: ...Appendix B Mode Switch Bank Settings B 4 6H122 16 User s Guide...
Страница 158: ...Index Index 4 6H122 16 User s Guide...