Appendix A: Specifications
A-2
6H122-16 User’s Guide
A.4
INPUT/OUTPUT PORTS
6H122-16 Specifications
A.5
COM PORT PINOUT ASSIGNMENTS
The COM port is a serial communications port that supports Local
Management or connection to a UPS.
The COM port has the following pin assignments:
A.6
REGULATORY COMPLIANCE
Safety
The 6H122-16 meets the safety requirements of UL 1950, CSA C22.2
No. 950 and EN 60950, IEC 950, and 73/23/EEC.
Electromagnetic Compatibility (EMC)
The 6H122-16 meets the requirements of FCC Part 15, EN 50082-1,
EN 55022, VCCI V-3, CSA C108.8, AS/NZS 3548 and 89/336/EEC.
Ports 1 through 16
Fast Ethernet 10/100 Mbps
(100BASE-TX compliant) with RJ45
type connectors.
Table A-1
COM Port Pin Assignments
Pin
Signal Name
Input/Output
1
Transmit Data (XMT)
Output
2
Data Carrier Detect (DCD)
Output
3
Data Set Ready (DSR)
Input
4
Receive Data (RCV)
Input
5
Signal Ground (GND)
NA
6
Data Terminal Ready (DTR)
Output
7
Request to Send (RTS)
Input
8
Clear to Send (CTS)
NA
Содержание 6H122-16
Страница 2: ......
Страница 8: ...Notice vi 6H122 16 User s Guide...
Страница 40: ...Chapter 4 Troubleshooting 4 8 6H122 16 User s Guide...
Страница 148: ...Chapter 5 Local Management 5 108 6H122 16 User s Guide...
Страница 154: ...Appendix B Mode Switch Bank Settings B 4 6H122 16 User s Guide...
Страница 158: ...Index Index 4 6H122 16 User s Guide...