Calibrate Device
Switch on the device.
Start menu.
Select
Setup
>
Labelling
>
Calibrate device
.
Insert a 10-mm test pipe (Part No. 5988543).
Select
Continue
.
The wrapping unit will be turned ten times with closing and opening the jaws and measuring the diameter of the
test pipe.
The display shows the success of the calibration, the determined offset and the tolerances of the offset value.
Select
Continue
.
The determined offset will automatically be stored and considered for future measurements.
6.2
Special JScript Commands
i
Note!
Some parameters of the menu
Setup > Labelling
can be changed or overridden by JScript commands in a print
job.
These changes are valid for the current print job only.
!
Attention!
The meaning of the commands O Ax=y in the following table are valid for WICON only.
For other applicators the meaning of these commands are different.
Command O Ax=y
x
Meaning
Value range y
Default
Example
1
Wrap start
START signal
Automatic
Automatic
O A1=START signal
Table 4
O Ax commands
!
Attention!
The y-values must be set as shown in the table regarding blanks and case sensitivity.