GENERAL INDEX

Introduction

Installation of the machine

Description

pag. 1

Shipment and transit

pag. 1

General use of the machine

pag. 2

Adjustment for slush consistency

pag. 3

Lift upper lid

pag. 4

Pre-mix product and refill the machine

pag. 4

Control panel

pag. 5

Timer programming

pag. 5

Instructions to start the machine

pag. 5

Disconnect lid

pag. 6

Remove upper agitator

pag. 6

How to empty bowl

pag. 7

Removal the bowl

pag. 7

Removal the spiral

pag. 8

Removal suction cap gasket

pag. 8

Removal bowl gasket

pag. 8

How to remove the tap components

pag. 9

Reassembly of the bowl gasket

pag. 10

Reassembly of the suction cap gasket

pag. 10

Reassembly of the spiral

pag. 10

Reassembly of the tap

pag. 11

Reassembly of the bowl

pag. 12

Maintenance of the filter

pag. 13

Maintenance of the condenser

pag. 13

Maintenance of the gaskets

pag. 13

Reset the machine if external filter is obstructed

pag. 14

Compressor check

pag. 15

Set pressostat

pag. 15

Lock for lid

pag. 16

Handle lock

pag. 16

General Explose

pag. 17

Gear motor explose

pag. 18

Spare parts list

pag. 19

Electrical table

pag. 20

Troubleshooting

pag. 21

General index

pag. 22

Cleaning operation

Reassembly of the components

General Maintenance

Safety operation

Optional

Replacement parts and reference drawings

Troubleshooting

Index

19

Содержание FABY 3

Страница 1: ...Manual n 151010 Ott 2010 SERVICE MANUAL FABY 3 MODEL C A B Via Campana 233 Pozzuoli NA 80078 I T A L Y S p A http www cabspa com Mail info cabspa com P o Box 39 081 5261111 ...

Страница 2: ...rstood If problems develop or questions arise in connection with installation operation or servicing of the slush machine contat your distributor The slush machine has been assembled operated and inspected at the factory Upon arrival at the final destination the complete slush machine must be checked for any damage which may have occurred during transit With the method of packaging used the slush ...

Страница 3: ...ines are equipped with air cooled condenser and require correct ventilation The left side is the air intake and must be unobstructed Air discharge out is on the right side Do not obstruct the discharge Pic 4 Pic 6 Pic 7 Pic 5 Pay attention to the voltage Be sure there is a ground pole Do not plug more than one machine in to one socket Extensions cords not recommended GENERAL USE OF THE MACHINE ...

Страница 4: ...in order to increase the thickness Rotate counterclockwise in order to decrease the thickness of the slush see pict 9 The machine has been adjusted for fruit granitas normal Products containing milk or other products which may take longer to freeze adjust as shown in picture S L U S H ADJUSTMENT W H E E L N O R M A L M E D I U M M A X I M U M Pic 8 Pic 9 Pic 10 ...

Страница 5: ...keep at least 1 above cylinder at all times Refill with refrigerated product when level is halfway between min and max levels Pic 16 This way there will always be frozen product available for customers Attention do not pour hot product in the tank INSTALLATION OF THE MACHINE Pic 13 Pic 12 Pic 15 Pic 14 lift the upper lid gently and put it on one side of the machines drip tray panel by using the ap...

Страница 6: ...n the right local time Please noteAM PM signs pic 19 After timer setting it is possible to start the machine with some simple operations Without the correct time setting the timer will not work properly Turn on the INDIVIDUAL BOWL FREEZE switches C as shown in picture 19 Turn on the MAIN POWER switch A as shown in picture 19 The Turn on the LIGHT switch B as shown in picture 19 N B INSTRUCTIONS TO...

Страница 7: ...g operation empty the bowl again Place fingers behind the bowl legs and pull the bowl onwards slowly until it has been completely removed For an easy removal of the bowl Please follow instructions shown in Pictures 26 27 ATTENTION Place all the components in a safe place in order to be sure they are not lost NOTE Do not use too hot water to clean the plastic components Clean the components with di...

Страница 8: ... part of the evaporator tube see Pict 31 Once the spiral blade is removed completely remove the suction cap gasket from the front spiral as shown in Pict 30 ATTENTION Place all the components in a safe place in order to be sure they are not lost NOTE Do not use too hot water to clean the plastic components Clean the components with dish washing soap and tepid water Never use abrasive cleaners 7 ...

Страница 9: ... 33 3 Unthread the main tap pin by pulling it downwards see Pict 34 4 Repeat the same operation for the tap spring see Pict 35 ATTENTION Place all the components in a safe place in order to be sure they are not lost NOTE Do not use too hot water to clean the plastic components Clean the components with dish washing soap and tepid water Never use abrasive cleaners Pic 34 8 ...

Страница 10: ... Pict 40a 40b After this it is important to lubricate the head of the spiral see Pict 34 1 2 1 Lubricate 2 REASSEMBLY OF THE COMPONENTS Put the bowl gasket in its position on the back part of the evaporator tube Once the bowl gasket is in its right position press it with your thumbs first in the lower part and then progressively towards its upper part marking a circle with your fingers until it is...

Страница 11: ...ards until you are able to see the square hole where you will insert the handle see Pict 44 Insert the pin for handle fixing as indicated in Pict 45 LUBRICATE I N S I D E Before reassembling of the tap components lubricate the tap siege as indicated in Pict 41 and lubricate the seals as indicated in Pict 43 Pic 41 HOLE Insert the tap spring and tap pin as indicated in Pic 41 and 42 Pic 44 10 ...

Страница 12: ... the bowl gasket site It is important that the bowl hole corresponds perfectly to the gasket shape To obtain this easily lift slighly the back part of the bowl when insering it Press the bowl deeply see Pict 46 and 47 Once the bowl is inserted deeply press with the fingers on the legs and push downwards until you hear the clap See Pict 47 and 47a If this operation can seem difficult you may also p...

Страница 13: ... not forget to clean the condenser periodically every month is the optimal time Remove the screw as shown in Pict 50 and clean condenser with an appropriate brush see Pic 51 ATTENTION Adirty condenser causes damages to the compressor Every month it is necessary to check the gaskets indicated in Picture 52a 52b and 52c If the suction spiral s cap 2 05 is damaged not assembled correctly or wore out ...

Страница 14: ...k from the lower part of the tap see Pict 61 With the handle lock you have two options for ex During the night Insert the handle lock as indicated in Pict 62 and close the little lock In this way it is not possible to open or remove any part of the tap therefore the dispensing of the slush is not allowed for During the day Insert the handle lock as shown in Pict 63 And close the little lock In thi...

Страница 15: ...GENERAL EXPLOSE 14 ...

Страница 16: ... EXPLOSE EXPLOSE POSITION NUMB 4 01 see general explose to pag 17 POSIT 19 GASKET GEAR POS 10 GEAR POS 8 GEAR POS 7 GEAR POS 6 POSIT 1 COIL POSIT 25 FAN 4 01 25 4 01 1 4 01 19 4 01 10 4 01 8 4 01 7 4 01 6 T N 15 ...

Страница 17: ...OWL CROSS BAR F302 N COMPLETE BOWL F 139 LUBRICATION TUBE 5 02 F010 CROSS BAR Posit No Code Description 5 03 F174 TAP HANDLE LOCK 5 11 F227 PUSH STICKER 5 04 F012 N HANDLE BLACK PUSH STICKER 5 05 F013 PIN FOR HANDLE FIXING 5 06 F014 TAP SPRING 5 07 F015 TAP PIN 5 08 F016 TAP O RING 5 09 F017 LOWER GASKET FOR TAP 5 10 F315 3 BOWLBUSHING 6 11 F214 1 COMPRESSOR FABY 3 115V 60HZ 6 16 F083 9 START COND...

Страница 18: ...icro switch 2 14 Light 1 A Main power switch B Individual bowl freeze refrigeration switch C Main freeze refrigeration switch Mod 2 and Mod 3 D Light switch G Individual bowl freeze refrigeration switch Mod 2 e Mod 3 Electro valve 3 13 Micro switch 2 15 Light2 16 Light 3 5 4 3 2 1 6 C 8 9 10 12 13 11 C N C NC NC 7 D C M M 3 2 M 1 V A A E V 1 E V E V 2 3 T 1 B G G 16 15 14 17 ...

Страница 19: ...O THE REFRIGERATION CIRCUIT CONTACT YOUR DISTRIBUTOR INTERNAL MECHANICAL TROUBLE IN COMPRESSOR REPLACE COMPRESSOR Contact distributor NOT ENOUGH SUGAR ORTOO MUCH WATER EMPTY BOWL REMIX PRODUCT see pag 4 COMPRESSOR NOT STARTING CHECK COMPRESSOR GAS LEAK INTO THE REFRIGERATION CIRCUIT CONTACT YOUR DISTRIBUTOR FAN MOTOR IS BURNT REPLACE FAN MOTOR Pos 6 26 INCORRECT VENTILATION SEE PAG 2 Pic 4 and 5 L...

Страница 20: ...nents pag 9 Reassembly of the bowl gasket pag 10 Reassembly of the suction cap gasket pag 10 Reassembly of the spiral pag 10 Reassembly of the tap pag 11 Reassembly of the bowl pag 12 Maintenance of the filter pag 13 Maintenance of the condenser pag 13 Maintenance of the gaskets pag 13 Reset the machine if external filter is obstructed pag 14 Compressor check pag 15 Set pressostat pag 15 Lock for ...

Страница 21: ...NOTE 20 ...

Страница 22: ......

Отзывы: