11
Fig. 7
Turn away and Dismount the applicator
!
Attention!
Initiation, adjustments and changing of parts is only for qualified service personal only.
!
Attention!
Disconnect the printer from the power supply before mounting the applicator!
Ensure a stable standing of the printer!
Connect the compressed air only after mounting the applicator to the printer!
For cleaning the applicator and printer it is sometime necessary to turn away or/and dismount the appli-
cator. Don't change the adjustments of setting screws, throttle valves or other.
So it is possible the use the applicator direct after remounting.
Turn away / Dismount the applicator
1. To turn away the control assembly loosen thumbscrew (7) and swing the applicator.
2. Disconnect SUB-D 15 male connector (8) to the female connector (9) of the printer.
3. Loosen screw (6) and move off the locking plate (5) from hinges.
4. Lift the control assembly upward.
5. Loosen screws (2) and take up base plate with swing cylinder.(1).
Mount the applicator
6. Set the base plate with swing cylinder.(1) on the bottom side of the printer. The holes on the base plate must be
over the holes in the printer chassis. Tighten the screws (2) to mount the base plate (1) on the printer.
7. Control assembly hang with the female part (3) of hinges at the printer hinges male parts (4).
8. To secure the applicator to slip out of hinges loosen screw (6) and move metal part (5) under the hinges and
tighten screw (6).
9. Connect SUB-D 15 male connector (8) to the female connector (9) of the printer.
10. Swing the applicator to the printer and tighten the thumbscrew (7).
1
2
3
4
8
9
5
6
7
4
3