background image

 COPYRIGHT & TRADEMARKS 

Copyright© 2004 C4Line, All Right Reserved. CrossPower is a trademark of C4Line. Intellon, PowerPacket, and No 

New Wires are registered trademarks of Intellon Corporation. HomePlug is a registered trademark of the 

HomePlug Powerline Alliance. Microsoft, Windows, and the Windows logo are registered trademarks of Microsoft 

Corporation. All other trademarks and brand names are the property of their respective proprietors. 

 

 LIMITED WARRANTY 

C4Line guarantees that every CrossPower C4L5200-ETH Bridge and CrossPower C4L5200-USB Adapter 

will be free from physical defects in material and workmanship for one year from the date of purchase, 

when used within the limits set forth in the Specification section of this User Guide. If the product 

proves defective during this warranty period, call C4Line Technical Support in order to obtain a Return 

Process  Information.  BE  SURE  TO  HAVE  YOUR  PROOF OF PURCHASE AND A BARCODE FROM THE 

PRODUCTS PACKAGING ON HAND WHEN CALLING. RETURN REQUESTS CANNOT BE PROCESSED 

WITHOUT PROOF OF PURCHASE. When returning a product, please include a copy of your original 

proof of purchase. All customers located outside of the United State of America shall be held 

responsible for shipping and handling charges. 
 
IN NO EVENT SHALL C4LINE’S LIABILITY EXCEED THE PRICE PAID FOR THE PRODUCT FROM DIRECT, 

INDIRECT SPECIAL, INCIDENTIAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE 

PRODUCT, ITS ACCOMPANYING SOFTWARE, OR ITS DOCUMENTATION. C4LINE DOES NOT OFFER 

REFUNDS FOR ANY PRODUCT. C4Line makes no warranty or representation, expressed, implied, or 

statutory, with respect to its product or the contents or use of this documentation and all 

accompanying software, and specifically disclaims its quality, performance, merchantability, or fitness 

for any particular purpose. C4Line reserves the right to revise or update its products, software, or 

documentation without obligation to notify any individual or entity. Please direct all inquires to; 

 

C4Line(KOREA) 903, Chungang B/D, 402-3, Shindorim-dong, Guro-gu, KOREA.     

 

 FCC STATEMENT 

The CrossPower C4L5200-ETH Bridge have been tested and complies with the specifications for a Class 

B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference in a residential installation. This equipment generates, uses, 

and can radiate radio frequency energy and, if not installed and used according to the instructions, 

may cause harmful interference to radio communications. However, there is no guarantee that 

interference will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which is found by turning the equipment off and on, the 

user is encouraged to try to correct the interference by one or more of the following measures; 

• Reorient or relocate the receiving antenna 

• Increase the separation between the equipment or devices 

• Connect the equipment to an outlet other than the receiver’s 

• Consult a dealer or an experienced radio/TV technician for assistance 

This  device  complies  with  part  15  of  the  FCC  Rules. Operation is subject to the following two 

conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 

interference received, including interference that may cause undesired operation. 

 

1

Caution : Any changes or modifications in construction of this device which are not expressly 

approved by the party responsible for compliance could void the user's authority to operate the 

equipment. 

Содержание CrossPower C4L5200-ETH

Страница 1: ...C4Line CrossPower C4L5200 ETH Ethernet to Powerline Bridge Manual...

Страница 2: ...all accompanying software and specifically disclaims its quality performance merchantability or fitness for any particular purpose C4Line reserves the right to revise or update its products software...

Страница 3: ...s 1 4 Applications 1 5 Usage 2 Installation Guide Step 1 Plan the Installation of Your Powerline Network Step 2 Installing C4L5200 ETH Setup Utility Software Step 3 Using C4L5200 Configuration Utility...

Страница 4: ...on the computer By offering 56 bit DES encryption it is also much more secure than other home networking technologies such as wireless Ethernet This manual is intended to provide basic information to...

Страница 5: ...available ETH interface At least one other powerline enabled device HomePlug 1 0 Compliant Windows 98SE ME 2000 or XP Additional router may be required to connect multiple users 1 4 Applications Share...

Страница 6: ...LINE ACTIVITY ON PowerLine activity transmit or receive BLINKING looking for more PowerLine devices OFF Device is in reset or device is not attached to AC power DS3 POWERLINE LINK ON Another PowerLine...

Страница 7: ...the following CrossPower C4L5200 ETH adapter Node mode for each PC with an Ethernet port or CrossPower C4L5200 USB adapter Node mode for each PC with USB port To set up files to be sharing two things...

Страница 8: ...lder open My Computer and navigate to the folder to share right click on the folder and select Sharing and Security Click the checkbox saying Share this folder on the network and click OK To access ot...

Страница 9: ...nection Using the CrossPower C4L5200 ETH Bridge Node mode and C4L5200 USB Node to play game remotely to share Broadband Internet access through the whole house and to extend the WiFi network as follow...

Страница 10: ...t before installing this software Insert the Setup utility CD ROM into the computer s CD ROM drive The setup utility should run automatically If it doesn t click the Start button and choose Run In the...

Страница 11: ...Click the Next button to continue 10 Enter a Username and Organization then click the Next button to continue...

Страница 12: ...Click Install 11...

Страница 13: ...H cable into the C4L5200 ETH and an available ETH port on your PC Click OK Important Because the C4L5200 ETH sends data over the powerline it is recommended that you plug its power cord directly into...

Страница 14: ...sh button to exit the Setup Utility Software You may be asked to restart your computer Click the Yes button to restart now or click the No button to restart later 13 The installation of the C4L5200 ET...

Страница 15: ...mmended that the same PC chosen for initial execution of this utility remain the PC of choice for subsequent network encryption updates Network setup information is stored on the PC and is used to fac...

Страница 16: ...rts the Device dialog screen Figure Initial screen when wizard is started State shows the MAC address of the device that your computer is connected to Referesh scan for the Powerline Adapter that is c...

Страница 17: ...that your PC is connected to the same device Now you are ready to manage the powerline network connected to this device ensure its privacy and measure its data rate performance Press Refresh button to...

Страница 18: ...twork button to refresh the listed information Figure Network dialog screen Important In case a C4L5200 device in your home is not listed in the screen above make sure that its network password has no...

Страница 19: ...devices are shipped using HomePlug as a network password The Security dialog screen allows you to change this network password and set your own private password and apply it to the C4L5200 device con...

Страница 20: ...ox and hit Add This will add the passwords to Remote Passwords text list box and set them to the currently defined Network Password Note The device must be present on the powerline in order for the pa...

Страница 21: ...creen After completing the installation successfully through Setup Configuration Utility Software you may need to perform additional steps to ensure that your Powerline network is fully functional The...

Страница 22: ...line node using the same computer that the node is connected to If this fails there is a problem with the network interface Repeat the same process with the other Powerline nodes on the network If all...

Страница 23: ...thernet Port Link Data Rate Access Methods Operating Frequency Up to 14Mbps CSMA CA 25MHz Frequency Band Modulation 4 3 to 20 9 MHz OFDM Orthogonal Frequency Division Multiplexing with automatic Chann...

Страница 24: ...to your computer For use with a router connect a straight through UTP Category 5 cable to the uplink port of the router or connect a crossover UTP Category 5 cable to a LAN port on the router 2 I can...

Страница 25: ...mum limits of the HomePlug 1 0 1 Specification each C4L5200 can communicate with 15 simultaneous bridge or node devices at full speed Each entry in the simultaneous device list is aged every 10 second...

Страница 26: ...nicating over the powerline with the full rate adaptive speed enabled by a valid tone map 3 ROBO mode device connections are those that communicate at 1Mbps using the ROBO mode tonemap C4Line Korea 90...

Отзывы: