c3controls 900 Series Скачать руководство пользователя страница 8

WE DIDN’T INVENT CONTROL, WE’RE PERFECTING  IT.

8

SERIES 900 SMART 

PROGRAMMABLE RELAYS

FUNCTIONS

SETTING THE CLOCK

1.  Select the “UTILITIES” option from the main menu and press OK.

2.  Select the “SET CLOCK” option from the sub menu and press OK.

3.  The cursor will blink on the first digit of the date, press ALT to edit the digit. 

4.  The digit will now start blinking. 

5.  Using Up (Z4) and Down (Z2) keys select the appropriate digit.

6.  Now press Z3 to edit the other digit and using Up and Down keys select the digit.

7.  Now press OK to confirm the changes that have been made.

8.  Repeat the same procedure to set the month, year, hour and minutes.

9.  Once all the parameters have been set, press OK to save the changes and exit. 

PASSWORD

The password secures access to the following main menu options: 

”PROGRAM”, ”PARAMETERS”, and ”UTILITIES”.

In RUN mode password protects the run time parameters and ladder viewing. 

The password comprises four numeric digits from 0 to 9. Therefore the 

password can have any value between 0 and 9999. 

SETTING THE PASSWORD

1.  Select the “UTILITIES” option from the main menu and press OK.

2.  Select the “PASSWORD” option from the sub menu and press OK.

3.  The unlock symbol means that the password is not yet set.

4.  The cursor will blink on the first digit of the date, press the ALT key to edit 

the digit. 

5.  The digit will now start blinking.

6.  Using Up (Z4) and Down (Z2) keys select the appropriate digit.

7.  Now press Z3 to edit the other digit and using the Up and Down keys 

select the digit.

8.  Press OK to confirm the password.

9.  Press OK again to enable the password and return to the main menu.

REMOVING THE PASSWORD

1.  Select the “UTILITIES” option from the main menu and press OK.

2.  Select the “PASSWORD” option from the sub menu and press OK.

3.  The lock symbol means that the password is set.

4.  The cursor will blink on the first digit, press ALT to edit the digit.

5.  The digit will now start blinking.

6.  Using Up (Z4) and Down (Z2) keys select the appropriate digit.

7.  Now press Z3 to edit the other digit and using Up and Down keys                 

select the digit.

8.  Repeat the same procedure to set all 4 digits.

9.  Now press OK to confirm the changes that have been made.

10. Pressing OK again, the password is disabled and the main menu is 

displayed.

EXPANSION MODULE SELECTION

1.  Select the “UTILITIES” option from the main menu and press OK.

2.  Select the “EXT MOD” option from the sub menu and press OK.

3.  The cursor will be blinking on ‘A’, press ALT to edit and the ‘A’ will start 

blinking. 

4.  Press Up (Z4) or Down (Z2) keys to select or deselect the expansion module.

5.  A dark square around ‘A’ indicates that the module has been selected.

6.  Now press OK to confirm the changes that have been made.

7.  Repeat the same procedure if the other modules are to be selected.

8.  Press OK to save the changes and the ‘UTILITIES’ sub menu is displayed.

PROGRAM PROTECTION

1.  If the password is already enabled and user attempts to gain access using 

wrong password, then an error message is displayed. 

2.  If four such consecutive attempts are made then user is presented with 

options to either delete the entire device data or else revert. 

3.  If the DELETE ALL option is selected, then all device data including Password 

and program are erased. The user can then reprogram using SPR Soft 

software and secure it with a new password. 

After four wrong attempts of entering the Password the Screen as shown below 

appears. Pressing OK here will delete all device data or press ESC to return to 

previous screen (pressing ESC will not delete).

AUTO:   In AUTO mode, whenever a key is pressed the backlight will be 

               switched ON and will switch OFF after 10 seconds.

ON:        In ON mode, the backlit will be permanently switched ON.

OFF:      In OFF mode, the backlit will be permanently switched OFF.

BACKLIT CONFIGURATION

1.  Select the “UTILITIES” option from the main menu and press OK.

2.  Select the “BACKLIT CONFIG” option from the sub menu and press OK.

3.  The ‘AUTO’ option will be displayed with the cursor blinking on it.

4.  Press ALT to edit and the AUTO option will start blinking. 

5.  Press Up (Z4) or Down (Z2) keys to select other options:  ON, OFF.

6.  Now press OK to confirm the changes that have been made.

7.  Press OK to save the changes and the ‘UTILITIES’ sub menu is displayed.

If only one expansion (extension) module is being used and it has been 

assigned as ‘A’ on the expansion module using the selection switch then 

make sure that ‘A’ is selected in the ‘EXT MOD’ option in the ‘UTILITIES’ 

menu. If more than one expansion module is being used then make sure 

that the modules have been assigned and selected appropriately because 

this in turn will affect the inputs and the outputs.

OK

OK

OK

Z4

ALT

PROGRAM

RUN

PARAMETERS

UTILITIES

PASSWORD

PASSWORD

SET CLOCK

PASSWORD

EXT MOD

BACKLIT CON

PASSWORD

PASSWORD

ENABLED

PASSWORD

PROGRAM

RUN

PARAMETERS

UTILITIES

7

7 2 5 7

7 2 5 7

OK

OK

Z3

Z4

Z4

ALT

PROGRAM

RUN

PARAMETERS

UTILITIES

DD/MM/YY

11/01/11

HH:MM

09:30

SET CLOCK

PASSWORD

EXT MOD

BACKLIT CON

DD/MM/YY

11/01/11

HH:MM

09:30

DD/MM/YY

01/01/11

HH:MM

09:30

DD/MM/YY

15/01/11

HH:MM

09:30

DD/MM/YY

01/01/11

HH:MM

09:30

SAVING DATA

.  .  .  WAIT

OK

OK

OK

Z4

ALT

PROGRAM

RUN

PARAMETERS

UTILITIES

PASSWORD

PASSWORD

SET CLOCK

PASSWORD

EXT MOD

BACKLIT CON

PASSWORD

PASSWORD

ENABLED

PASSWORD

PROGRAM

RUN

PARAMETERS

UTILITIES

7

7 2 5 7

7 2 5 7

OK

ALT

Z4

OK

PROGRAM

RUN

PARAMETERS

UTILITIES

SAVING DATA

.  .  .  WAIT

SET CLOCK

PASSWORD

EXT MOD

BACKLIT CON

EXTENSION

MODULES

A         B         C

EXTENSION

MODULES

A         B         C

SET CLOCK

PASSWORD

EXT MOD

BACKLIT CON

EXTENSION

MODULES

A   

      B         C

OK

OK

OK

Z4

OK

ALT

PROGRAM

RUN

PARAMETERS

UTILITIES

BACKLIT

CONFIG

ON

SET CLOCK

PASSWORD

EXT MOD

BACKLIT CON

BACKLIT

CONFIG

ON

BACKLIT

CONFIG

AUTO

SAVING DATA

.  .  .  WAIT

BACKLIT

CONFIG

AUTO

SET CLOCK

PASSWORD

EXT MOD

BACKLIT CON

OK

PASSWORD

INVALID

PASSWORD

. . . try later

OK

OK

PASSWORD

INITIALIZING

DEVICE DATA

. . . WAIT

DELETE ALL?

Содержание 900 Series

Страница 1: ...Y GUARANTEED SAME DAY SHIPPING ADVANTAGE PRICING 1 SMART PROGRAMMABLE RELAYS SERIES 900 INSTRUCTION MANUAL LIFETIME WARRANTY GUARANTEED SAME DAY SHIPPING ADVANTAGE PRICING WE DIDN T INVENT CONTROL WE...

Страница 2: ...h can be used as digital inputs Ability to add up to three 3 expansion modules expanding I O s to 32 digital inputs 16 relay outputs Communication module allows programmable relay to be connected to a...

Страница 3: ...lso selects deselects links ESC This key is used to exit the menu or a selection During the parameter entry it proceeds to the next parameter without saving the changes ARROW On the program editor scr...

Страница 4: ...sent in the incoming power supply it may be necessary to insert an isolation transformer between the supply and the line terminals of the Series 900 relay 2 While using the DC Series 900 relay run the...

Страница 5: ...C2 AN AN 2 1 C1 6 5 INPUT 6 X DC AN1 AN2 0 10 V DC 12 24 V DC 6 5 4 2 1 3 4 2 1 I P O P 3 C A B 8 7 OP1 OP3 OP2 OP4 64 9mm 2 35 64 45mm 1 49 64 72mm 2 53 64 90 5mm 3 9 16 100mm 3 15 16 4 3mm 11 64 SEL...

Страница 6: ...not change the states of the inputs outputs and special functions and continues with the execution of the program When the cursor is on the PARAMETERS option and OK is pressed then screen 4 will be di...

Страница 7: ...r SOFT TEXT MESSAGES The Series 900 relay provides 16 soft text message blocks which can be used to display text messages the preset value and current value of any special function block or the curren...

Страница 8: ...splayed PROGRAM PROTECTION 1 If the password is already enabled and user attempts to gain access using wrong password then an error message is displayed 2 If four such consecutive attempts are made th...

Страница 9: ...RANSFER function allows data to be transferred from Memory Card to the Series 900 relay or vice versa Transferring data to the memory card is useful when the user wants to load the same program in man...

Страница 10: ...confirm the changes that have been made 14 Press Z3 to select STOPBIT and press ALT to edit 15 Using Up Z4 and Down Z2 keys select the number of stop bits 16 Press OK to confirm the changes that have...

Страница 11: ...clock date and time on the Series 900 relay CREATING A NEW PROGRAM Select File New from the menu bar to create a new program A blank screen will appear Now you can start entering the program Ensure th...

Страница 12: ...ectable as 1200 2400 4800 9600 baud PARITY Selectable as NONE EVEN and ODD STOP BIT Selectable as 1 and 2 Stop Bits CLOCK SETTING 1 Select the Transfer Device Clock menu command The Device Clock windo...

Страница 13: ...w and select Time Switch 1 1 2 Move the cursor to the Contact 1 column of the first row and left click on the block to place the Time Switch 3 Right click on the Time Switch and select properties to o...

Страница 14: ...indow and select I2 4 Move the cursor to the Contact 1 column of the second row and left click on the block to place the input Also place it in the Contact 1 column of the third row COUNTER SELECTION...

Страница 15: ...ximum Input Frequency Hz 10 5 10 5 Analog Inputs Number of Analog Inputs 2 NA 2 NA Input Range V 0 10V DC 10 bit resolution NA 0 10V DC 10 bit resolution NA Input Impedance W 8 NA 8 NA Maximum Input V...

Страница 16: ...ck feed delivery OTHER APPLICATIONS Solar electric systems Marine applications Harsh environments Display panels and traffic control signs APPLICATIONS ORDERING INFORMATION 900 SBA8I4OZC 900 SBA8I4OM...

Отзывы: