c3controls 900 Series Скачать руководство пользователя страница 2

WE DIDN’T INVENT CONTROL, WE’RE PERFECTING  IT.

2

SERIES 900 SMART 

PROGRAMMABLE RELAYS

INTRODUCTION

Providing excellent performance and functionality, the Series 900 relay performs simple logic, timing, counting, and real time clock operations. It is 

an ideal programmable controller designed for use in small commercial and industrial automation sectors, including packaging machines, printing 

machines, commercial building controls, parking controls, lighting applications, and more, where cost is a primary design issue. All programming and 

data adjustments can be done via the on-board keypad and display or with the help of the software.

Programming the Series 900 relay with the SPR-soft III software is quite simple, even without particular programming knowledge. It facilitates 

program generation, project simulation, and documentation which are accomplished simply by using the pick and place functionality, allowing 

maximum ease of operation. 

BASE MODULE

EXPANSION MODULE

COMMUNICATION MODULE

THE C3CONTROLS 

SERIES 900 SMART PROGRAMMABLE RELAY

 PROVIDES THE RIGHT SOLUTION FOR ALL YOUR CONTROL NEEDS!

FEATURES

•  Integrated, ready to use, wide range of programmable functions 

including 16 timers, 16 (retentive selectable) counters, 16 time switches, 

16 compare counters, 16 soft text messages, 64 auxiliary relays and 12 

analog comparators.

•  8 digital inputs & 4 relay outputs. Two analog inputs (0-10V) in 12-24V 

DC, model which can be used as digital inputs.

•  Ability to add up to three (3) expansion modules expanding I/O’s to 32 

digital inputs, 16 relay outputs. 

•  Communication module allows programmable relay to be connected to 

a Modbus network through RS 485 link.

•  Backlit LCD screen for display and modification of pre-selected 

parameters of function blocks, viewing I/O status and programming on 

the device.

•  Ladder programming using software on PC as well as on the device with 

the help of keypad & LCD display.

•  Memory back up allowing programs to be transferred or copied into 

another Series 900 relay with the help of a memory card.

•  Compact size 72mm (2-53/64”) wide x 90mm (3-35/64”) high x 65mm (2-

9/16”) deep, reducing panel area requirements for lower installed costs.

•  Soft keys for convenient creation and editing of programs on the device.
•  Available in both: AC (110-240V AC) & DC (12-24V DC) models.
•  Password & Parameter lock facility.

EXPANSION MODULE

•  Can be used with base module to increase I/O capacity of the Series 900 relay.
•  8 digital inputs & 4 digital outputs. 
•  Connections are made in Daisy chain fashion. 
•  The Series 900 relay can be expanded by connecting 3 expansion 

modules, to obtain a maximum configuration of 32 inputs and 16 outputs.

COMMUNICATION MODULE

•  Provides Modbus communication through an RS 485 link. 
•  Possible to connect multiple Series 900 relays with a SCADA system or 

an HMI over RS 485.

•  Available in both AC (110-240V AC) & DC (12-24V DC) models.
•  The connection between the communication module and Series 900 

relay base module is made through the communication module’s     

cable (included).  

ACCESSORIES

APPROVALS

USB CABLE

SERIAL CABLE

MEMORY CARD

Содержание 900 Series

Страница 1: ...Y GUARANTEED SAME DAY SHIPPING ADVANTAGE PRICING 1 SMART PROGRAMMABLE RELAYS SERIES 900 INSTRUCTION MANUAL LIFETIME WARRANTY GUARANTEED SAME DAY SHIPPING ADVANTAGE PRICING WE DIDN T INVENT CONTROL WE...

Страница 2: ...h can be used as digital inputs Ability to add up to three 3 expansion modules expanding I O s to 32 digital inputs 16 relay outputs Communication module allows programmable relay to be connected to a...

Страница 3: ...lso selects deselects links ESC This key is used to exit the menu or a selection During the parameter entry it proceeds to the next parameter without saving the changes ARROW On the program editor scr...

Страница 4: ...sent in the incoming power supply it may be necessary to insert an isolation transformer between the supply and the line terminals of the Series 900 relay 2 While using the DC Series 900 relay run the...

Страница 5: ...C2 AN AN 2 1 C1 6 5 INPUT 6 X DC AN1 AN2 0 10 V DC 12 24 V DC 6 5 4 2 1 3 4 2 1 I P O P 3 C A B 8 7 OP1 OP3 OP2 OP4 64 9mm 2 35 64 45mm 1 49 64 72mm 2 53 64 90 5mm 3 9 16 100mm 3 15 16 4 3mm 11 64 SEL...

Страница 6: ...not change the states of the inputs outputs and special functions and continues with the execution of the program When the cursor is on the PARAMETERS option and OK is pressed then screen 4 will be di...

Страница 7: ...r SOFT TEXT MESSAGES The Series 900 relay provides 16 soft text message blocks which can be used to display text messages the preset value and current value of any special function block or the curren...

Страница 8: ...splayed PROGRAM PROTECTION 1 If the password is already enabled and user attempts to gain access using wrong password then an error message is displayed 2 If four such consecutive attempts are made th...

Страница 9: ...RANSFER function allows data to be transferred from Memory Card to the Series 900 relay or vice versa Transferring data to the memory card is useful when the user wants to load the same program in man...

Страница 10: ...confirm the changes that have been made 14 Press Z3 to select STOPBIT and press ALT to edit 15 Using Up Z4 and Down Z2 keys select the number of stop bits 16 Press OK to confirm the changes that have...

Страница 11: ...clock date and time on the Series 900 relay CREATING A NEW PROGRAM Select File New from the menu bar to create a new program A blank screen will appear Now you can start entering the program Ensure th...

Страница 12: ...ectable as 1200 2400 4800 9600 baud PARITY Selectable as NONE EVEN and ODD STOP BIT Selectable as 1 and 2 Stop Bits CLOCK SETTING 1 Select the Transfer Device Clock menu command The Device Clock windo...

Страница 13: ...w and select Time Switch 1 1 2 Move the cursor to the Contact 1 column of the first row and left click on the block to place the Time Switch 3 Right click on the Time Switch and select properties to o...

Страница 14: ...indow and select I2 4 Move the cursor to the Contact 1 column of the second row and left click on the block to place the input Also place it in the Contact 1 column of the third row COUNTER SELECTION...

Страница 15: ...ximum Input Frequency Hz 10 5 10 5 Analog Inputs Number of Analog Inputs 2 NA 2 NA Input Range V 0 10V DC 10 bit resolution NA 0 10V DC 10 bit resolution NA Input Impedance W 8 NA 8 NA Maximum Input V...

Страница 16: ...ck feed delivery OTHER APPLICATIONS Solar electric systems Marine applications Harsh environments Display panels and traffic control signs APPLICATIONS ORDERING INFORMATION 900 SBA8I4OZC 900 SBA8I4OM...

Отзывы: