23
TROUBLESHOOTING
(a) Check the condition of batteries under load using the battery monitor symbol. (See
Battery Check Procedure).
(b) Check that the search head is properly attached to the control box via the search head
cable connector.
(c) Interchange batteries and ensure batteries are correctly seated in the holder and that
the battery connector is securely attached to the battery holder.
Oscillating Signal
(a) This could be due to poor battery connections. Ensure that they are tight and the
batteries are securely clipped into place.
(b) Loose search head cable connection - tighten.
(c) Interference from a vehicle using a radio transmitter, or possibly a stationary source of
electromagnetic radiation such as an electric fence or radio transmitter. If this occurs
then reduce the sensitivity. If the problem persists then the best remedy is to wait until
the transmission stops.
Intermittent Sound from Speaker
(a) This could be due to poor battery connections. Ensure that they are tight and the
batteries are securely clipped into place.
(b) Loose search head cable connection - tighten.
(c) Ensure search head cable is pushed into the cable slots in the lower stem.
(c) Radio interference (see above).
Poor or No Contrast on Display
(a)
This could be due to poor battery condition. Ensure that batteries are in good
condition.
(b)
The R1 internal storage could be corrupted. To reset the detector ensure the R1 is
turned OFF, press and hold the ENTER button, turn the R1 ON wait 5 seconds. You
will be asked if you wish to reset the detector. Use the MENU/SCROLL control to
highlight YES then press the ENTER button. The R1 will then be reset to factory
settings.
No Sound or Partial Sound from Headphones
(a)
On headphones fitted with stereo/mono switch, ensure stereo is selected.
(b)
Ensure headphone connector is fully inserted into socket.
(c)
Try another set headphones or try headphones on another piece of equipment.