Depth Measurement using Sonde/ Plastic Pipe Tracer
(end mode only)
1. Pinpoint the exact position of the Sonde as shown in the “Non-metallic Pipes”
section. Take care to ensure that you are over the top of the Sonde and not over
one of the two “ghost” signals in front of and behind the true position.
2. Rest the Locator on the ground, keeping it vertical and IN LINE with the Sonde.
3. Push the depth button TWICE and hold, on the second push, to select Sonde
mode. The word Sonde will flash on the display and the depth will then be
displayed. If the word Sonde is not displayed then the depth reading will not
be accurate.
Depth Measurement: Error Readings
The Cable Avoidance Tool XD may show the following error codes when a depth
measurement has been attempted.
1. The service is too shallow (less than 0.20m deep) for the Locator to
obtain an accurate depth. It should be possible to calculate the depth by raising the Locator a set amount and then carry-
ing out the depth measurement again.
2. The service is too deep for the Locator to measure its depth.
3. The Signal Generator signal on the buried service is not strong enough for the Locator to give a reliable depth
measurement. Increasing the Signal Generator output or repositioning the Signal Generator to give a stronger signal
should solve the problem.
4. Overload. The signal is too strong for the Locator to give a reliable depth measurement. Reducing the Signal
Generator output to give a weaker signal should solve the problem
NOTE The depth shown is that of the sonde and NOT of the pipe.
Accuracy is to the nearest 0.15m. Range is 0.8m to 5.0m.
3.
32