Signal Generator:
Searching for an Induced Signal
4. Walk in a straight line across the end line of the Signal
Generator. When a signal is detected ‘pinpoint’ that signal as
shown in the ‘Using the Locator’ section. If no signal is found
move the Signal Generator 5 metres and try again. Continue this
procedure moving the Signal Generator in 5 metre steps, following
a grid pattern, until a signal can be found.
5. It may be possible to increase the strength of the induced signal
on the buried service by improving the positioning of the Signal
Generator. Once the buried service has been pinpointed then by
moving the position of the Signal Generator slightly either side an
increase or decrease in the locator response will be noticed.
Remember the closer the Signal Generator is to the position of the
buried service then the stronger the signal will be on that service.
NOTE The Generator signal that the locator is detecting will get weaker the further away from the Signal
Generator that you go. It will be necessary to regularly adjust (increase) the Sensitivity to compensate for this.
22